Lead the motor and mains cables through the 
bottom plate.

ENSURE MAINS SUPPLY TO INSTALLATION IS OFF. 
LOCK THE DISCONNECTOR TO OPEN POSITION.
ACx 600 MUST BE INSTALLED BY A COMPETENT PERSON. 
IF IN DOUBT DO NOT INSTALL.

1

1. Measure the places for four screw holes.
Mark the hole positions. 2. Drill the holes. 
3. Screw in the screws.

2

Position ACx 600 onto screws and securely 
tighten in all four corners. 

Note: Lift ACx 600 

by its chassis, not by its cover.

1. Undo the two screws. 2. Lift the lower edge 
of the cover. 3. Disconnect the cable from 
connector X2. Remove the cover.

STOP

FOR 

INSTALLATION 

OF OPTIONAL 

EQUIPMENT, SEE 

SEPARATE 

INSTRUCTIONS 

INCLUDED IN 

THE DELIVERY.

4

5

1. Strip off the insulation from the motor cable 
and mains cable. Twist the screen wires into 
bundles. 2. Make suitable holes to motor and 
mains cable grommets.

Before Starting Installation

CHECK BOX CONTENTS: ACx 601, Manual(s), Testing report, Ordered options, Quick Guide(s)
CHECK INSTALLATION SITE AMBIENT CONDITIONS: See Manual.
CHECK INSTALLATION SPACE: ACx 600 free space requirements are 300 mm above and below, 50 mm on the left and on the right.
CHECK INSTALLATION SURFACE: Vertical, smooth and solid, free from heat, damp and condensation.
CHECK ACCESSORIES NEEDED: See Manual for fuse, supply disconnecting device and cable specifications.

3

Mains cable

OUTPUT

STOP

CHECK THE 

INSULATIONS 

OF MOTOR, 
AND MAINS 

AND MOTOR 

CABLE. 

See Manual.