![ABB ACQ80-04 Series Firmware Manual Download Page 187](http://html.mh-extra.com/html/abb/acq80-04-series/acq80-04-series_firmware-manual_2932187.webp)
Additional parameter data 187
30.02 Torque limit status
0b0000…0b1111
-
1 = 1
30.09 Cur Lim Monitor Time
0.00...120.00
s
-
30.10 Current Limit Actions
0...2
-
1=1
30.11 Minimum speed
-30000.00…30000.00
rpm
100 = 1 rpm
30.12 Maximum speed
-30000.00…30000.00
rpm
100 = 1 rpm
30.13 Minimum frequency
-500.00…500.00
Hz
100 = 1 Hz
30.14 Maximum frequency
-500.00…500.00
Hz
100 = 1 Hz
30.17 Maximum current
0.00…7.20
A
100 = 1 A
30.19 Minimum torque 1
-1600.0…0.0
%
10 = 1%
30.20 Maximum torque 1
0.0…1600.0
%
10 = 1%
30.31 Undervoltage control
0…1
-
1 = 1
30.35 Thermal current limitation
0...1
-
1 = 1
30.36 Speed limit selection
-
-
1 = 1
30.37 Min speed source
-
-
1 = 1
30.38 Max speed source
-
-
1 = 1
31 Fault functions
31.01 External event 1 source
-
-
1 = 1
31.02 External event 1 type
0…1
-
1 = 1
31.03 External event 2 source
-
-
1 = 1
31.04 External event 2 type
0…1
-
1 = 1
31.05 External event 3 source
-
-
1 = 1
31.06 External event 3 type
0…1
-
1 = 1
31.07 External event 4 source
-
-
1 = 1
31.08 External event 4 type
0…1
-
1 = 1
31.09 External event 5 source
-
-
1 = 1
31.10 External event 5 type
0…1
-
1 = 1
31.11 Fault reset selection
-
-
1 = 1
31.12 Autoreset selection
0x0000…0xffff
-
1 = 1
31.13 Selectable fault
0x0000…0xffff
-
1 = 1
31.14 Number of trials
0…5
-
1 = 1
31.15 Total trials time
1.0…600.0
s
10 = 1 s
31.16 Delay time
0.0…120.0
s
10 = 1 s
31.19 Motor phase loss
0…1
-
1 = 1
31.20 Earth fault
0…2
-
1 = 1
31.21 Supply phase loss
0…1
-
1 = 1
31.22 STO indication run/stop
0…5
-
1 = 1
31.23 Wiring or earth fault
0…1
-
1 = 1
31.24 Stall function
0…2
-
1 = 1
31.25 Stall current limit
0.0…1600.0
%
10 = 1%
31.26 Stall speed limit
0.00…10000.00
rpm
100 = 1 rpm
31.27 Stall frequency limit
0.00…1000.00
Hz
100 = 1 Hz
31.28 Stall time
0…3600
s
1 = 1 s
31.30 Overspeed trip margin
0.00…10000.00
rpm
100 = 1 rpm
31.31 Frequency trip margin
0.00...10000.00
Hz
100 = 1 Hz
32 Supervision
32.01 Supervision status
0b0000…0b1111
-
1 = 1
32.05 Supervision 1 function
0…7
-
1 = 1
32.06 Supervision 1 action
0…3
-
1 = 1
32.07 Supervision 1 signal
-
-
1 = 1
32.08 Supervision 1 filter time
0.000…30.000
s
1000 = 1 s
32.09 Supervision 1 low
-21474836.00…
21474836.00
-
-
32.10 Supervision 1 high
-21474836.00…
21474836.00
-
-
32.11 Supervision 1 hysteresis
0.00…100000.00
-
100 = 1
32.15 Supervision 2 function
0…7
-
1 = 1
No.
Name
Type
Range
Unit
FbEq32
ACQ80 FW.book Page 187 Thursday, February 14, 2019 11:33 AM
Summary of Contents for ACQ80-04 Series
Page 4: ...4 ACQ80 FW book Page 4 Thursday February 14 2019 11 33 AM ...
Page 10: ...10 Table of contents ACQ80 FW book Page 10 Thursday February 14 2019 11 33 AM ...
Page 16: ...16 Introduction to the manual ACQ80 FW book Page 16 Thursday February 14 2019 11 33 AM ...
Page 28: ...28 Using the control panel ACQ80 FW book Page 28 Thursday February 14 2019 11 33 AM ...
Page 54: ...54 Program features ACQ80 FW book Page 54 Thursday February 14 2019 11 33 AM ...
Page 196: ...196 Additional parameter data ACQ80 FW book Page 196 Thursday February 14 2019 11 33 AM ...
Page 220: ...220 Fault tracing ACQ80 FW book Page 220 Thursday February 14 2019 11 33 AM ...