35.02
BRAKE MONITOR 1
Selects the source 1 for activating external brake
on/off supervision (when par.
BRAKE
CONTROL = ENABLE 1 NC, ENABLE 1 NO, ENA
1&2 NC, ENA 1&2 NO). The use of the external
on/off supervision signal is optional.
• When parameter
BRAKE CONTROL =
ENABLE 1 NO or ENA 1&2 NO, 1 = The brake is
open, 0 = The brake is closed.
• When parameter
BRAKE CONTROL =
ENABLE 1 NC or ENA 1&2 NC, 1 = The brake is
closed. 0 = The brake is open.
Brake supervision is normally controlled with a digital
input. It can also be controlled with an external
control system, eg, fieldbus.
When brake control error is detected the drive reacts
as defined by parameter
BRAKE FAULT
FUNC.
Note
: This parameter cannot be changed while the
drive is running.
C.False /
Bit pointer: CONST or POINTER (See
on page
.)
35.03
BRAKE MONITOR 2
Selects the source 2 for activating external brake
on/off supervision (when parameter
BRAKE
CONTROL = ENABLE 2 NC, ENABLE 2 NO, ENA
1&2 NC, ENA 1&2 NO. The use of the external on/off
supervision signal is optional.
• When parameter
BRAKE CONTROL =
ENABLE 2 NO or ENA 1&2 NO, 1 = The brake is
open. 0 = The brake is closed.
• When parameter
BRAKE CONTROL =
ENABLE 2 NC or ENA 1&2 NC, 1 = The brake is
closed. 0 = The brake is open.
Brake supervision is normally controlled with a digital
input. It can also be controlled with an external
control system, eg, fieldbus.
When brake control error is detected the drive reacts
as defined by parameter
BRAKE FAULT
FUNC.
Note
: This parameter cannot be changed while the
drive is running.
C.False /
Bit pointer: CONST or POINTER (See
on page
.)
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...