background image

Figures   99

Hex screw M12×35 
full thread 70 N·m 
(52 lbf·ft) Washer 
M12 or equal

Hex nut M12 70 N·m 
(52 lbf·ft) Washer M12 
or equal

Combi screw M6×20 Torx 
T25 2 N·m (18 lbf· in)

O

P

Q

R

S

T

Combi screw M6×20 
Torx T25 2 N·m 
(18 lbf·in)

Combi screw M4×10 Torx T20 
2 N·m (18 lbf·in)

+B051

+B051

+B051

+B051

+B051

+B051

+B051

Summary of Contents for ACH580-04

Page 1: ...drive modules Quick installation guide English 3 English USA 9 Dansk 17 Deutsch 23 Espa ol 29 Suomi 35 Fran ais 41 Italiano 47 Dutch 53 Polski 59 Portugu s 65 71 Svenska 77 T rk e 83 89 EN USA DA DE E...

Page 2: ...mmunication adapter quick guide 3AXD50000018457 CPTC 02 ATEX certified thermistor protection module Ex II 2 GD L537 Q971 user s manual 3AXD50000030058 FBIP 21 BACnet IP adapter module user s manual 3A...

Page 3: ...m another person Keep a constant pressure with one foot on the base of the module to prevent the module from falling on its back WARNING If you are not a qualified electrical professional do not do in...

Page 4: ...tion see the hardware manual Protect the drive and input power cables See Fuses IEC on page 95 for aR fuses for protection against short circuit in the input power cable or drive Install the drive mod...

Page 5: ...you suspect moisture dry the motor and repeat the measurement Check the grounding system compatibility EMC filter compatibility The drive has an internal EMC filter E210 as standard You can install th...

Page 6: ...ds of figure O around the motor cables P 99 12 Option B051 Remove the plastic sheeting from both sides of the output clear plastic shroud Install the shroud to the drive module Q 99 13 Option B051 Ins...

Page 7: ...the cabinet entry 2 Ground the pair cable shields of external control cables to a grounding clamp below the control unit Leave the other end of the shields unconnected or ground them indirectly via a...

Page 8: ...tput and programmable digital inputs 10 24V Aux voltage output 24 V DC max 250 mA 11 DGND Aux voltage output common 12 DCOM Digital input common for all 13 DI1 Stop 0 Start 1 14 DI2 Not configured 15...

Page 9: ...fully preferably with help from another person Keep a constant pressure with one foot on the base of the module to prevent the module from falling on its back WARNING If you are not a qualified electr...

Page 10: ...drive modules hardware manual 3AXD50000048685 English Protect the drive and input power cables See Fuses UL on page 95 for branch circuit protection per NEC Obey local regulations Install the drive mo...

Page 11: ...you suspect moisture dry the motor and repeat the measurement Check the grounding system compatibility EMC filter compatibility The drive has an internal EMC filter E210 as standard However for the U...

Page 12: ...t cover to the drive module Q 99 Step Task input cables Figure Page 1 Ground the input cable shields if present 360 degrees at the cabinet entry 2 Connect the twisted shields of the input cables and s...

Page 13: ...at the cabinet entry 2 Ground the pair cable shields of external control cables to a grounding clamp below the control unit Leave the other end of the shields unconnected or ground them indirectly vi...

Page 14: ...output and programmable digital inputs 10 24V Aux voltage output 24 V DC max 250 mA 11 DGND Aux voltage output common 12 DCOM Digital input common for all 13 DI1 Stop 0 Start 1 14 DI2 Not configured 1...

Page 15: ...current The output current is derated for 40 55 C The drive is suitable for use in a circuit capable of delivering not more than 100000 rms symmetrical amperes 480 V maximum when protected by the UL...

Page 16: ...16 EN Quick installation guide North America USA USA DE ES FI FR IT NL PL PT RU SV TR ZH...

Page 17: ...etrammen inden du skubber det ind i kabinettet Udf r arbejdet forsigtigt helst med hj lp fra en anden person Hold et konstant tryk med n fod p modulets fod for at forhindre modulet i at v lte bagover...

Page 18: ...e oplysninger i hardwaremanualen Beskyt frekvensomformeren og forsyningskablet Se Fuses IEC p side 95 for aR sikringer til beskyttelse mod kortslutning i forsyningskablet eller frekvensomformeren Inst...

Page 19: ...gt skal motoren t rres og m lingen gentages Kontroller det jordede systems kompatibilitet EMC filterkompatibilitet Frekvensomformeren har som standard et internt EMC filter E210 Du kan montere frekven...

Page 20: ...tikafd kning Monter afd kningen p frekvensomformermodulet Q 99 13 Ekstraudstyr B051 Monter nederste frontafd kning p frekvensomformermodulet Q 99 Trin Opgaver indgangskabler Figur Side 1 Jord indgangs...

Page 21: ...k rme for alle eksterne styrekabler 360 grader ved kabinetindgangen 2 Jord de sk rmede snoede kabler for eksterne styrekabler til en jordklemme under styrekortet Lad den anden ende af sk rmene v re fr...

Page 22: ...pesp nding og programmerbare digitalindgange 10 24V Udg ende hj lpesp nding 24 V DC maks 250 mA 11 DGND Hj lpesp nding nulpotentiale 12 DCOM Digitalindgang f lles for alle 13 DI1 Stop 0 Start 1 14 DI2...

Page 23: ...llt sichern Sie es an den oberen Hebe sen mit Ketten am Schaltschrankgeh use bevor Sie das Modul in den Schrank hineinschie ben Arbeiten Sie vorsichtig am besten zusammen mit einem Helfer Dr cken Sie...

Page 24: ...erforderlich ist 7 Fordern Sie die Arbeitsfreigabe von der Person an die f r die elektrische Installation verantwortlich ist Auswahl der Leistungskabel Die Leistungskabel m ssen nach den rtlichen Vor...

Page 25: ...or dem Anschlie en des Netzkabels an den Frequenzumrichter die Isolation entsprechend den vor Ort geltenden Vorschriften Siehe Abbildung H auf Seite 98 Die Motorkabelschirme motorseitig an Erde PE ans...

Page 26: ...ul schrauben und festziehen Auf den Isolatoren die Anschlussklemmen T3 W2 installieren WARNUNG Es d rfen keine l ngeren Schrauben oder h heren Anzugsmomente als die in der Montagezeichnung angegebenen...

Page 27: ...sschiene anschlie en 3 Option B051 Bohren Sie f r den Anschluss der Kabel vorsichtig ausreichend gro e ffnungen in die Klarsichtabdeckung am Kabeleingang Die Bohrl cher m ssen genau senkrecht entprech...

Page 28: ...ng nge 10 24V Hilfsspannungsausgang 24 V DC max 250 mA 11 DGND Hilfsspannungsausgang Masse 12 DCOM Masse f r alle Digitaleing nge 13 DI1 Stopp 0 Start 1 14 DI2 Nicht konfiguriert 15 DI3 Auswahl Konsta...

Page 29: ...mente con la ayuda de otra persona Mantenga un pie apoyado en la base del m dulo para evitar que caiga sobre su parte posterior ADVERTENCIA Si usted no es electricista cualificado no realice trabajos...

Page 30: ...El rango de temperatura de funcionamiento permitido para el convertidor de frecuencia sin derrateo es de 15 a 40 C Para obtener m s informaci n v ase el Manual de hardware Proteja el convertidor y los...

Page 31: ...na tensi n de prueba de 1000 V CC La resistencia de aislamiento de un motor ABB debe ser superior a los 100 Mohmios valor de referencia a 25 C Para la resistencia de aislamiento de otros motores consu...

Page 32: ...alonada taladre en las carcasas interiores de pl stico transparente orificios con el di metro suficiente para los cables de motor que va a conectar Suavice las aristas de los orificios Haga un corte d...

Page 33: ...res a los terminales apropiados de la unidad de control V ase la p gina 34 4 Cablee los m dulos opcionales si est n incluidos en el suministro 4 Opcional B051 Inserte los conductores de los cables de...

Page 34: ...de tensi n auxiliar y entradas digitales programables 10 24V Salida de tensi n aux 24 V CC m x 250 mA 11 DGND Salida de tensi n auxiliar com n 12 DCOM Com n de todas las se ales digitales 13 DI1 Paro...

Page 35: ...Noudata ty ss huolellisuutta On suositeltavaa k ytt toista henkil apuna Paina moduulin jalustaa jatkuvasti toisella jalalla jotta moduuli ei p se kaatumaan sel lleen VAROITUS Asennus ja huoltot it saa...

Page 36: ...ilman kertoimia on 15 40 C Lis tietoja on laiteoppaassa Suojaa taajuusmuuttaja ja sy tt kaapelit Sy tt kaapelin ja taajuusmuuttajan oikosulkusuojaukseen soveltuvat aR sulakkeet on lueteltu kohdassa F...

Page 37: ...imenpide Tarkista maadoitusj rjestelm n yhteensopivuus EMC suotimen yhteensopivuus Taajuusmuuttajassa on vakiovarusteena sis inen EMC suodin E210 EMC suotimella varus tettu taajuusmuuttaja voidaan ase...

Page 38: ...a suojamuovi l hd n kirkkaan muovisuojuksen molemmilta puolilta Asenna suojus taajuusmuuttajamoduuliin Q 99 13 Lis varuste B051 Asenna etukannen alaosa taajuusmuuttajamoduuliin Q 99 Vaihe Toimenpide s...

Page 39: ...kien ulkoisten ohjauskaapelien ulkovaipat 360 astetta kaapin l pivienniss 2 Maadoita parikaapelien suojavaipat ohjausyksik n alapuolella olevaan maadoituskiinnikkeeseen J t suojavaippojen toiset p t m...

Page 40: ...V DC enint 250 mA 11 DGND Apuj nnitemaa 12 DCOM Kaikille yhteinen digitaalitulo 13 DI1 Seis 0 K y 1 14 DI2 Ei m ritetty 15 DI3 Vakiotaajuuden nopeuden valinta 16 DI4 K ynnistyslukitus 1 1 salli k ynn...

Page 41: ...re effectu e avec pr caution Maintenez une pression constante avec un pied sur la base du module pour l emp cher de basculer sur l arri re ATTENTION Seul un lectricien qualifi est autoris effectuer la...

Page 42: ...n Protection du variateur et des c bles r seaux Voir section Fuses IEC page 95 pour les fusibles aR servant prot ger le c ble r seau ou le variateur des courts circuits Montage du module variateur en...

Page 43: ...ous reporter la documentation du fabricant Nota La pr sence d humidit l int rieur de l enveloppe du moteur r duit sa r sistance d isolement Si vous soup onnez la pr sence d humidit s chez le moteur et...

Page 44: ...en plastique transparent d un diam tre suffisant pour laisser passer les c bles moteur bavurez les per ages tez la partie vid e afin de pouvoir passer la protection autour des c bles Retirez le film p...

Page 45: ...d un condensateur haute fr quence de quelques nanofarads ex 3 3 nF 630 V 3 Raccordez les conducteurs aux bornes correspondantes de l unit de commande Cf page 46 4 Raccordez les modules optionnels si...

Page 46: ...logiques programmables 10 24V Sortie de tension auxiliaire 24 Vc c maxi 250 mA 11 DGND Commun sortie tension auxiliaire 12 DCOM Commun toutes entr es logiques 13 DI1 Arr t 0 D marrage 1 14 DI2 Non con...

Page 47: ...ne preferibilmente con l aiuto di un altra persona Esercitare una pressione costante con un piede alla base del modulo per evitare che cada all indietro AVVERTENZA Gli interventi di installazione e ma...

Page 48: ...range di temperatura operativa del convertitore senza declassamento 15 40 C Per ulteriori informazioni vedere il Manuale hardware Protezione del convertitore e dei cavi della potenza di ingresso Vede...

Page 49: ...di 1000 Vcc La resistenza di isolamento dei motori ABB deve essere superiore a 100 Mohm valore di riferimento a 25 C Per la resistenza di isolamento di altri motori consultare le istruzioni del produ...

Page 50: ...grado di protezione IP20 Nelle protezioni interne in plastica trasparente praticare con attenzione dei fori di grandezza sufficiente al passaggio dei cavi motore da collegare Smussare i bordi dei fori...

Page 51: ...ri ai corrispondenti morsetti dell unit di controllo Vedere pag 52 4 Collegare i moduli opzionali se inclusi nella fornitura 4 Opzione B051 Infilare i conduttori dei cavi di ingresso nei fori praticat...

Page 52: ...ssi digitali programmabili 10 24V Uscita tensione ausiliaria 24 Vcc max 250 mA 11 DGND Comune uscite tensione ausiliaria 12 DCOM Comune ingressi digitali per tutti 13 DI1 Arresto 0 Marcia 1 14 DI2 Non...

Page 53: ...oon Houd met n voet een constante druk op de onderkant van de module om te voorkomen dat de module achterover valt WAARSCHUWING Als u geen gekwalificeerd elektrotechnicus bent mag u geen installatie o...

Page 54: ...n naar de hardwarehandleiding Beveilig de omvormer en de voedingskabels Zie Fuses IEC op pagina 95 voor de aR zekeringen ter beveiliging tegen kortsluiting in de voedingskabel of omvormer Installeer d...

Page 55: ...g verlaagt de isolatieweerstand Als u vocht vermoedt moet u de motor drogen en de meting herhalen Controleer de compatibiliteit van het aardingssysteem EMC filter compatibiliteit De omvormer heeft sta...

Page 56: ...htige kunststof uitgangsafdekking Installeer de afdekking op de omvormermodule Q 99 13 Optie B051 Installeer de onderste frontkap op de omvormermodule Q 99 Stap Taak ingangskabels Figuur Pagina 1 Aard...

Page 57: ...ingen van alle externe besturingskabels over 360 graden bij de kastinvoer 2 Aard de kabelpaar afschermingen van externe besturingskabels aan een aardklem onder de besturingsunit Sluit het andere uitei...

Page 58: ...rbare digitale ingangen 10 24V Hulpspanningsuitgang 24 V DC max 250 mA 11 DGND Gemeenschappelijke aarde hulpspanningsuitgang 12 DCOM Gemeenschappelijke aarde voor alle digitale ingangen 13 DI1 Stop 0...

Page 59: ...moc a cuch w do ramy szafy a nast pnie wepchn modu do szafy Podczas pracy nale y zachowa ostro no Zaleca si skorzystanie z pomocy innej osoby Utrzymywa sta y nacisk jedn stop na podstaw modu u aby uni...

Page 60: ...e o stratach oraz przep ywie powietrza ch odz cego przez przemiennik cz stotliwo ci Dozwolony zakres temperatury pracy przemien nika cz stotliwo ci bez obni enia jego warto ci znamionowych wynosi od 1...

Page 61: ...api cia pomiarowego 1000 V DC Rezystancja izolacji silnika ABB musi przekracza 100 M warto odniesienia w temperaturze 25 C Wymagania dotycz ce rezystancji izolacji innych silnik w zosta y podane w dok...

Page 62: ...przezroczystego plastiku odpowiednio du e otwory aby zmie ci y si w nich pod czane kable silnika Wyr wna kraw dzie otwor w Naci os ony od otwor w do kraw dzi aby by o mo liwe umieszczenie os on wok k...

Page 63: ...o ciowy o pojemno ci kilku nanofarad w np 3 3 nF 630 V 3 Pod czy przewody do odpowiednich zacisk w karty sterowania Patrz str 64 4 Pod czy modu y opcjonalne je li s cz ci dostawy 5 Pod czy z cza wej c...

Page 64: ...ocniczego 24 V DC maks 250 mA 11 DGND Masa dla wyj cia napi cia pomocniczego 12 DCOM Wsp lne przy cze dla wej cyfrowych 13 DI1 Stop 0 Start 1 14 DI2 Nie skonfigurowano 15 DI3 Sta a cz stotliwo sta a p...

Page 65: ...ress o constante com um p na base do m dulo para evitar que o m dulo caia para tr s AVISO Se n o um profissional el trico qualificado n o realize qualquer trabalho de instala o ou de manuten o Leia es...

Page 66: ...l de hardware Proteja o acionamento e os cabos de entrada de pot ncia Consulte Fuses IEC na p gina 95 sobre os aR para prote o contra curto circuito no cabo de entrada de pot ncia ou no acionamento In...

Page 67: ...valor de refer ncia a 25 C Sobre a resist ncia do isolamento de outros motores consulte as instru es do fabricante Nota A presen a de humidade no interior da carca a do motor reduz a resist ncia do is...

Page 68: ...rio o grau de prote o IP20 Com cuidado fa a furos suficientemente grandes nos acr licos em pl stico transparente interiores para ligar os cabos do motor Alise as extremidades do furo Corte o acr lico...

Page 69: ...ns nanofarades ex 3 3 nF 630 V 3 Ligue os condutores aos terminais adequados da unidade de controlo Ver a p gina 70 4 Ligue a cablagem dos m dulos opcionais se inclu dos na entrega 5 Ligue os condutor...

Page 70: ...gitais program veis 10 24V Sa da tens o auxiliar 24 V CC max 250 mA 11 DGND Sa da de tens o auxiliar comum 12 DCOM Entrada digital comum para todas 13 ED1 Parar 0 Arrancar 1 14 ED2 N o configurado 15...

Page 71: ...RU 71 EN DA DE ES FI FR FR IT FR PL PT RU SV TR ZH RU 600 A 97 1 2 5 1 2 5 3AXD50000048686 B...

Page 72: ...72 RU EN DA DE ES FI FR IT NL PL PT RU RU TR ZH 3 4 5 1 L1 U1 L2 V1 L3 W1 PE 0 UDC UDC PE 0 6 7 96 15 40 C Fuses IEC 95 aR B 97 B051 C 97 D 97 B051 IP20...

Page 73: ...RU 73 EN DA DE ES FI FR FR IT FR PL PT RU SV TR ZH E 97 F 97 H 98 I 98 1000 ABB 100 25 C E210 TN S IT TT TN S IT TT Ground to phase varistor disconnecting instructions IEC not North America IEC...

Page 74: ...ES FI FR IT NL PL PT RU RU TR ZH B051 G 98 1 J 98 2 360 K 98 3 L 98 4 T3 W2 M 98 5 T3 W2 T3 W2 N 98 6 T2 V2 4 7 T2 W2 T2 W2 8 T1 U2 4 9 T1 U2 T1 U2 10 B051 IP20 O 99 11 B051 O P 99 12 B051 Q 99 13 B05...

Page 75: ...RU 75 EN DA DE ES FI FR FR IT FR PL PT RU SV TR ZH W 100 X 100 1 2 3 3 630 3 76 4 3 B051 R 99 4 B051 S 99 5 L1 U1 L2 V1 L3 W1 T 99 6 B051 U 100 7 U 100 8 U 100 9 B051 V 100...

Page 76: ...ND X2 X3 10 24V 24 250 11 DGND 12 DCOM 13 DI1 0 1 14 DI2 15 DI3 16 DI4 1 1 17 DI5 18 DI6 X6 X7 X8 19 RO1C 250 30 2 20 RO1A 21 RO1B 22 RO2C 250 30 2 23 RO2A 24 RO2B 25 RO3C 1 250 30 2 26 RO3A 27 RO3B X...

Page 77: ...en i sk pet Arbeta f rsiktigt helst med hj lp av en annan person H ll ett konstant tryck med foten mot modulens bas s att den inte v lter p rygg VARNING Installationsarbete och underh llsarbete f r en...

Page 78: ...information finns i Beskrivning av h rdvara Skydda frekvensomriktaren och matningskablarna Se Fuses IEC p sidan 95 f r aR s kringar f r skydd mot kortslutning i matningskabel eller frekvensomriktare I...

Page 79: ...pprepa m tningen Kontrollera jordningssystemets kompatibilitet EMC filterkompatibilitet Frekvensomriktaren har ett internt EMC filter E210 som standard Frekvensomriktaren kan installeras med EMC filtr...

Page 80: ...t skyddsplasten p b da sidor av det genomskinliga ber ringsskyddet Montera ber ringsskyddet p frekvensomriktarmodulen Q 99 13 Tillval B051 Montera den nedre frontk pan p frekvensomriktarmodulen Q 99 S...

Page 81: ...grader vid sk pets genomf ring 2 Jorda ledarparsk rmarna f r alla externa styrkablar med en jordkl mma under styrenheten L mna sk rmarnas motsatta ndar oanslutna eller jorda dem indirekt via en h gfr...

Page 82: ...ngar 10 24V Hj lpsp nningsutg ng 24 V DC max 250 mA 11 DGND Gemensam nolla f r hj lpsp nningsutg ngar 12 DCOM Digital ing ng gemensam f r alla 13 DI1 Stopp 0 Start 1 14 DI2 Ej konfigurerat 15 DI3 Val...

Page 83: ...ba lay n Tercihen ba ka bir personelden yard m alarak dikkatli al n Mod l n arkas zerine d mesini engellemek zere mod l n alt nda bir aya n z ile sabit bas n uygulay n UYARI Kalifiye bir elektrik i d...

Page 84: ...c n n izin verilen al ma s cakl aral 15 ila 40 C dir Daha fazla bilgi i in donan m k lavuzuna bak n S r c ve giri g kablolar n koruyun Giri g kablosunda veya s r c de k sa devreye kar korumaya y nelik...

Page 85: ...y n Topraklama sisteminin uyumlulu unu kontrol edin EMC filtresi uyumlulu u S r c de standart olarak dahili bir EMC filtresi E210 vard r S r c y EMC filtresi simetrik topraklamal TN S sistem IT sistem...

Page 86: ...alar motor kablolar n n etraf na yerle tirin P 99 12 Se enek B051 Plastik levhay k effaf plastik muhafazas n n her iki taraf ndan kar n Muhafazay s r c mod l ne tak n Q 99 13 Se enek B051 Alt n kapa s...

Page 87: ...Harici kontrol kablolar n n ift kablo blendajlar n kontrol nitesinin alt ndaki bir topraklama kelep esine topraklay n Blendajlar n di er ucunu bo ta b rak n veya birka nanofarad y ksek frekansl konda...

Page 88: ...ri ler 10 24V Yrd gerilim k 24 VDC maks 250 mA 11 DGND Yard mc gerilim k ortak ucu 12 DCOM T m i in dijital giri ortak ucu 13 DI1 Stop 0 Start 1 14 DI2 Yap land r lmad 15 DI3 Sabit frekans h z se imi...

Page 89: ...89 EN DA DE ES FI FR FR IT FR PL PT RU SV TR ZH 600 mm 97 A 1 2 5 1 1 2 5 3 4 5 1 Mohm L1 U1 L2 V1 L3 W1 PE 0 V UDC UDC PE 0 V 6 7 3AXD50000048686 B...

Page 90: ...90 EN DA DE ES FI FR IT NL PL PT RU SV TR ZH ZH 96 15 40 C 95 Fuses IEC 97 B B051 97 C 97 D B051 IP20 97 E 97 F 98 H 360 I 98 1000 VDC ABB 100 Mohm 25 C...

Page 91: ...RU SV TR ZH EMC EMC E210 EMC TN S IT TT TN S IT TT IEC B051 98 G 1 J 98 2 360 K 98 3 L 98 4 T3 W2 M 98 5 T3 W2 T3 W2 N 98 6 T2 V2 4 7 T2 V2 T2 V2 8 T1 U2 4 9 T1 U2 T1 U2 10 B051 IP20 O 99 11 B051 O P...

Page 92: ...92 EN DA DE ES FI FR IT NL PL PT RU SV TR ZH ZH 100 W 100 X 1 360 2 3 3 nF 630 V 3 93 4 3 B051 R 99 4 B051 S 99 5 L1 U1 L2 V1 L3 W1 T 99 6 B051 U 100 7 U 100 8 U 100 9 B051 V 100...

Page 93: ...AO1 0 10 V 8 AO2 0 20 mA 9 AGND X2 X3 10 24V 24 VDC 250 mA 11 DGND 12 DCOM 13 DI1 0 1 14 DI2 15 DI3 16 DI4 1 1 17 DI5 18 DI6 X6 X7 19 RO1C 250 V AC 30 V DC 2 A 20 RO1A 21 RO1B 22 RO2C 250 V AC 30 V D...

Page 94: ...94 EN DA DE ES FI FR IT NL PL PT RU SV TR ZH ZH...

Page 95: ...8557D 725A 4 725 1250 1950000 170M6016 820A 4 820 1600 3900000 170M6269 880A 4 880 1600 3900000 170M6269 Un 480 V 505A 4 505 800 465000 170M6012 1600 4150000 170M8557D 585A 4 585 1000 945000 170M6014...

Page 96: ...claration of conformity ACH580 04 Frame size Air flow Heat dissipation Noise m3 h cfm W dB A 505A 4 R10 1200 707 5602 72 585A 4 R10 1200 707 6409 72 650A 4 R10 1200 707 8122 72 725A 4 R11 1200 707 876...

Page 97: ...in Combi screw M4 8 Torx T20 2 N m 18 lbf in Rittal 4396 500 Combi screw M8 30 Hex 20 N m 14 75 lbf ft Tapping screw M6 12 Torx T30 Hex 9 N m 80 lbf in R10 1515 59 65 R11 1715 67 52 M6x20 Torx T25 8...

Page 98: ...ex nut M12 70 N m 52 lbf ft Washer M12 or equal 1 2 3 G H K I L J M N INPUT OUTPUT ACH580 04 U1 V1 W1 3 M PE PE PE L1 L2 L3 L1 L2 L3 PE L1 U1 L2 V1 L3 W1 UDC UDC T1 U2 T2 V2 T3 W2 PE ohm M 3 U1 V1 W1...

Page 99: ...bf ft Washer M12 or equal Hex nut M12 70 N m 52 lbf ft Washer M12 or equal Combi screw M6 20 Torx T25 2 N m 18 lbf in O P Q R S T Combi screw M6 20 Torx T25 2 N m 18 lbf in Combi screw M4 10 Torx T20...

Page 100: ...res Combi screw M4 8 Torx T20 2 N m 18 lbf in Combi screw M4 10 Torx T20 2 N m 18 lbf in Combi screw M6 20 Torx T25 2 N m 18 lbf in 1 U X V W Combi screw M4 10 Torx T20 2 N m 18 lbf in B051 B051 B051...

Page 101: ...e contacts can be found by navigating to abb com searchchannels Product training For information on ABB product training navigate to new abb com service training Providing feedback on ABB Drives manua...

Page 102: ...abb com drives 3AXD50000048686 Rev B MUL 2020 06 26 Copyright 2020 ABB All rights reserved Specifications subject to change without notice ACH580 04 manuals...

Reviews: