![ABB A43 User Manual Download Page 230](http://html.mh-extra.com/html/abb/a43/a43_user-manual_4297230.webp)
Communication with M-Bus
A43/A44
230
2CMC48001M0201
User Manual
Revision: C
send out data from the nearest date backward in time. Therefore it is recom-
mended that the system should check the date sent in the telegram to verify that
it is the requested date. If no data is stored in the meter for the specified date, or
for any date backward in time, the telegram will contain no load profile data
(only the interval length).
10.4.1 Readout of Load Profile Data
Read request for a specified date and quantity
A read request for a specified date and quantity is performed by sending the fol-
lowing SND_UD to the meter followed by a REQ_UD2 (all values are hexadec-
imal).
Byte No.
Size
Value
Description
1
1
68
Start character
2
1
0A
L-field, calculated from C field to last user data
3
1
0A
L-field, repeated
4
1
68
Start character
5
1
53/73
C-field, SND_UD
6
1
xx
A-field, address
7
1
51
CI-field, data send, LSB first
8
1
02
DIF size, 2 byte integer
9
1
EC
VIF time point, date, M-Bus data type G
10
1
FF
VIFE next byte is manufacturer specific
11
1
F9
VIFE extension of manufacturer specific VIFE's, next VIFE
specifies actual meaning.
12
1
xx
VIFE specifies data requested:
10: Active import energy register values at end of interval
12: Reactive import energy register values at end of interval
14: Input 1 register values at end of interval
16: Input 2 register values at end of interval
1C: Active export energy register values at end of interval
1E: Reactive export energy register values at end of interval
20: Apparent import energy register values at end of interval
22: Apparent export energy register values at end of interval
24: Input 3 register values at end of interval
26: Input 4 register values at end of interval
28: Current average values per interval
29: Voltage average values per interval
2A: THD voltage average values per interval
2B: THD current average values per interval
2C: Power factor average values per interval
13-14
2
xxxx
Date (M-Bus data type G, LSB byte sent first)
15
1
xx
CS checksum, calculated from C field to last data
16
1
16
Stop character
Summary of Contents for A43
Page 1: ...A43 A44 User Manual ...
Page 40: ...Meter Settings A43 A44 40 2CMC48001M0201 User Manual Revision C ...
Page 55: ...Technical Description 2CMC48001M0201 55 A43 A44 Revision C User Manual ...
Page 58: ...Technical Description A43 A44 58 2CMC48001M0201 User Manual Revision C ...
Page 61: ...Technical Description 2CMC48001M0201 61 A43 A44 Revision C User Manual ...
Page 75: ...Technical Description 2CMC48001M0201 75 A43 A44 Revision C User Manual ...
Page 84: ...Measurement Methods A43 A44 84 2CMC48001M0201 User Manual Revision C ...
Page 91: ...Measurement Methods 2CMC48001M0201 91 A43 A44 Revision C User Manual ...
Page 95: ...Measurement Methods 2CMC48001M0201 95 A43 A44 Revision C User Manual ...
Page 102: ...Communication with Modbus A43 A44 102 2CMC48001M0201 User Manual Revision C ...
Page 107: ...Communication with Modbus 2CMC48001M0201 107 A43 A44 Revision C User Manual ...
Page 131: ...Communication with Modbus 2CMC48001M0201 131 A43 A44 Revision C User Manual ...
Page 147: ...Communication with Modbus 2CMC48001M0201 147 A43 A44 Revision C User Manual ...
Page 154: ...Communication with Modbus A43 A44 154 2CMC48001M0201 User Manual Revision C ...
Page 157: ...Communication with Modbus 2CMC48001M0201 157 A43 A44 Revision C User Manual ...
Page 161: ...Communication with Modbus 2CMC48001M0201 161 A43 A44 Revision C User Manual ...
Page 166: ...Communication with Modbus A43 A44 166 2CMC48001M0201 User Manual Revision C ...
Page 180: ...Communication with M Bus A43 A44 180 2CMC48001M0201 User Manual Revision C ...
Page 182: ...Communication with M Bus A43 A44 182 2CMC48001M0201 User Manual Revision C ...
Page 188: ...Communication with M Bus A43 A44 188 2CMC48001M0201 User Manual Revision C ...
Page 195: ...Communication with M Bus 2CMC48001M0201 195 A43 A44 Revision C User Manual ...
Page 254: ...Communication with M Bus A43 A44 254 2CMC48001M0201 User Manual Revision C ...
Page 257: ...Communication with M Bus 2CMC48001M0201 257 A43 A44 Revision C User Manual ...