Operation Manual / A170-M.. - A175-M..
2 Safety / 2.5 Intended use
© Copyright 2021 ABB. All rights reserved.
HZTL4033_EN
Rev.H
July 2021
2.5
Intended use
Use on internal combustion engines in general
ABB turbochargers are intended for charging internal combustion engines.
To ensure compliance with the machinery directive 2006/42/EC when using on gas engines,
the turbocharger must be operated in an engine room classified as "not at risk of explosion".
This is in accordance with the position paper [2] relating to ATEX issued by EUROMOT [1].
The turbocharger supplies the engine with the air volume or air/gas mixture and the associ-
ated charging pressure required for operation.
The turbocharger is solely intended to be operated with a clockwise direction of rotation as
viewed from the turbine end.
The specific operating limits of the turbocharger were determined on the basis of informa-
tion from the enginebuilder about the intended use. These data are given on the rating
plate.
The use of the turbocharger is limited to the specific application released at the time of de-
livery.
ABB accepts no liability and rejects all warranty claims for any non-intended uses.
[1]Euromot = The European Association of Internal Combustion Engine Manufacturers
[2]Directive 94/9/EC concerning equipment and protective systems intended for use in po-
tentially explosive atmospheres (ATEX) The Euromot Position as of November 2003, ATEX
Euromot Position 191103
WARNING
Unapproved operation
Any operation of the turbocharger outside of its operating limits can be haz-
ardous to personnel.
u
Only operate the turbocharger within the operating limits.
u
Only trained personnel must operate the turbocharger.
The intended use of the turbocharger includes compliance with all regulations and condi-
tions. In particular, the following must be observed:
¡
Operation Manual
¡
Instructions of the enginebuilder
State of the art
The turbocharger is designed and manufactured according to the state of the art and is safe
to operate.
Perfect condition
The turbocharger must only be used when it is in a technically flawless condition and oper-
ated in compliance with its intended use.
Page
14
/
147