5.3.2 Output Size
Parent
Output Size
belongs to the type
Internal Anybus Device
, in the topic
I/O System
.
Cfg name
OutputSize
Description
The parameter
Output Size
defines the data size in bytes for the input area sent
to the PROFINET Master.
Usage
Output Size
is a PROFINET specific parameter.
Prerequisites
The option
PROFINET Anybus Device
must be installed.
Limitations
A limitation is the maximum device size for the
Internal Anybus Device
Allowed values
Allowed values are the integers 1-128 (8-1024 signal bits).
The default value is 64 (512 signal bits).
Additional information
Any other values than 1, 2, 4, 8, 16, 32, 64, or 128 will result in digital output size
rounded up to the closest of these values.
Application manual - PROFINET Anybus Device
41
3HAC050968-001 Revision: C
© Copyright 2008-2016 ABB. All rights reserved.