2TLC172248M0201, rev. C
27
www.abb.com/jokabsafety
2020-11-11
Mounting bolts
4 x M5
Weight (approx.)
LineStrong3D
LineStrong3DZ(X)
LineStrong3L/R
LineStrong3LZ(X)/RZ(X)
1.320 kg
2.200 kg
1.100 kg
2.000 kg
Safety-related characteristic data and Conformity
Conformity
European Machinery Directive 2006/42/EC
EN ISO 12100:2010, EN ISO 13850:2008, EN 60204-1:2006+A1:2009
EN 60947-1:2007+A1:2011, EN 60947-5-1:2004+A1:2009,
EN 60947-5-5:1997+A1:2005
EN ISO13849-1
Up to PL e, Cat. 4 depending upon system architecture
EN 62061
Up to SIL3 depending upon system architecture
Safety data
Mechanical reliability B
10d
PFH
D
Proof test interval (life)
MTTF
d
1.5 x 10
6
operations at 100mA load
<1.0x10
-7
21 years
214 years (8 cycles per hour/24 hours per day/365 days)
Certifications
TÜV, cULus
Information with regard to UL 508
Use 12AWG copper conductors only
Electrical Rating: A300 48W5
Type 1 Enclosure
Max. Switching Current / Volt / Amp: 120V 6A (720VA break) PF 0.38,
240V 3A (720VA break) PF 0.38