Diagnosis
7 – 8
Advant Controller AC 31 / Issued: 01.99
3
Class 4 error descriptions
Error number in
MW 255,08
Dec Hex
Detailed info 1 in
MW 255,09
Detailed info 2 in
MW 255,10
Detailed info 3 in
MW 255,11
Internal unit error
1
D
01
H
unit type
address
channel number
Cut wire (detection of open circuit)*
2
D
02
H
unit type
address
channel number
Analog output level error
3
D
03
H
unit type
address
channel number
Overload
4
D
04
H
unit type
address
channel number
Defective 10 V output
5
D
05
H
unit type
address
channel number
Overload and cut wire*
6
D
06
H
unit type
address
channel number
Short circuit
8
D
08
H
unit type
address
channel number
Short c cut wire*
10
D
0A
H
unit type
address
channel number
Ov short circuit
12
D
0C
H
unit type
address
channel number
Short c ov cut wire*
14
D
0E
H
unit type
address
channel number
The end of the program is not
detected by the system on startup.
129
D
81
H
-
-
-
A program syntax error is detected
on startup.
131
D
83
H
Program address
-
-
On startup the system detects that
the historical values memory is too
small (max. 256).
132
D
84
H
-
-
-
The cycle time is missing and
detected by the system on startup.
133
D
85
H
-
-
-
A missing label for a conditional
step is detected by the system on
startup.
135
D
87
H
Program address
-
-
The program is not started because
the number of units initialized on the
CS31 system bus is less than the
number specified during
configuration, KW 0,9.
138
D
8A
H
Number of units
selected during
configuration
(KW 0,9)
Number of actual
units on the CS31
system bus
-
The program is too large for the
memory.
140
D
8C
H
-
-
-
* An error is detected if previously configured by programming the CS31CO block.
Summary of Contents for 07CR41
Page 6: ...Contents 4 Advant Controller AC 31 Issued 08 99 3 ...
Page 62: ...Installation 4 14 Advant Controller AC 31 Issued 08 99 3 Figure 22 Extension XK 08 F1 l ...
Page 94: ...Programming 5 22 Advant Controller AC 31 Issued 01 99 3 ...
Page 110: ...Communication 6 16 Advant Controller AC 31 Issued 01 99 3 ...
Page 122: ...Appendix A 4 Advant Controller AC 31 Issued 08 99 3 ...
Page 123: ......