Preparations before removing the upper arm
Note
Action
Guide pin, M12x150: 3HAC13056-2
Remove two attachment screws (M12) in
opposite holes and replace them with guide
pins.
Note
Make sure that it is the screws that hold
the lower arm to the axis-3 gearbox that
are removed!
1
Guide pin, M12x200: 3HAC13056-3
Always use guide pins in pairs.
xx1300000659
Tip
Lubricate the guide pins with some grease
to make the upper arm slide better.
xx1300000747
Leave one of the remaining attachment
screws fitted, remove the other screws.
2
Removing the upper arm
Note
Action
xx1400002197
Note
Make sure the lift is done completely
leveled! In case of necessary adjustments,
use the shortening loops on the lifting ac-
cessory (chain), and make sure to place
the chain the right way through the loops.
1
Continues on next page
588
Product manual - IRB 6790
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
4 Repair
4.8.3 Replacing the axis-3 gearbox
Continued