Note
Action
xx1200001238
Unscrew five of the six attachment screws
under the balancing device.
Note
Leave the screw closest to the axis-1 motor
fitted.
xx1200001239
11
xx1700001593
Check the leak flow value on the flow sensor.
Note the value to be able to compare it when
repair is completed.
12
CAUTION
Turn off the air pressure supply.
13
Robot position
Use this procedure to jog the robot into position.
Note
Action
xx1200001132
Jog the robot into position:
•
Axis 1: no significance as long as the robot
is secured to the foundation.
•
Axis 2: -40°
•
Axis 3: +65° (approximately)
•
Axis 4: calibration position (0°)
•
Axis 5. +90°
•
Axis 6: calibration position (0°)
1
Continues on next page
Product manual - IRB 6790
507
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
4 Repair
4.8.1 Replacing the axis-1 gearbox
Continued