Note
Action
xx1200001070
Make sure the o-ring is present.
3
xx1200001066
Disconnect the motor cables.
4
xx1200001067
Remove the cable gland cover.
Make sure the gasket is not damaged.
Tip
Make a note in which direction the cable
gland hole is facing, if the motor will be re-
moved too. The motor shall be refitted in
the same position.
5
Use caution and pull out the motor cables.
6
Removing the axis-4 motor
Note
Action
CAUTION
Use caution when releasing the brakes!
Axis-4 can move unexpectedly!
1
Continues on next page
464
Product manual - IRB 6790
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
4 Repair
4.7.4 Replacing the axis-4 motor
Continued