Note
Action
CAUTION
Turn off the air pressure supply.
5
xx1300000742
Remove the SMB cover.
6
The battery can stay connected, to avoid the need of
synchronizing the robot.
CAUTION
If the battery stays connected, put (or hold) the SMB
cover in a safe position. The battery cable connectors
can otherwise be damaged.
7
Disconnecting the brake release unit
Note
Action
DANGER
Make sure that all supplies for electrical power and
hydraulic pressure are turned off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit
please read the safety information in the section
unit is sensitive to ESD on page 49
2
Take a picture or make notes of how the robot cabling
is positioned in regard to the brake release board.
3
xx1300000670
Remove the connectors X8, X9 and X10 from the
brake release board.
4
Continues on next page
Product manual - IRB 6790
249
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
4 Repair
4.4.4 Replacing the brake release unit
Continued
Summary of Contents for IRB 6790
Page 1: ...ROBOTICS Product manual IRB 6790 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 164: ...This page is intentionally left blank ...
Page 612: ...This page is intentionally left blank ...
Page 638: ...This page is intentionally left blank ...
Page 644: ...This page is intentionally left blank ...
Page 658: ...This page is intentionally left blank ...
Page 660: ...This page is intentionally left blank ...
Page 667: ......