Solares™ Smart Spa Bathing System Operating Manual
CD0036
- 34 -
1121
your facilit
y’
s plumbing cannot keep up with
the tub’s drain.
Reservoir Max Fill Time
–
The maximum
amount of time it should take the reservoir to
fill. This value can be increased if
the facility’s
plumbing cannot fill the reservoir in time. This
value does not need to be particularly close to
the actual fill time as the top float sensor
stops the tank from overfilling. The important
thing is that it is set higher than the fill time
you expect to see as this should only come
into play if the top float sensor fails.
Tub Max Fill Time
–
The maximum amount of
time the tub should take to fill. Will throw an
error if filling takes longer. Only used to
prevent the tub from overfilling too long if the
top water sensor were to fail.
Tub Medium Fill Time
–
The amount of time
the tub should continue filling once it reaches
the middle water sensor to reach the medium
water fill height.
Thermistor Calibration
The tub’s thermist
ors can be easily calibrated
to ensure that they are reading as accurately
as possible.
Calibrating tub thermistor:
1.
Go to the bathing screen and open the
drain if it is not open already.
2.
Hit “Tub Fill” to start running water into
the tub.
3.
Wait for the
“filling temperature” to
match the set temperature displayed
above.
4.
Use a cup or mug to catch the water
coming out of the tub
’
s intake and
measure the temperature of the water
using a thermometer. (You can also close
the drain and measure the water
accumulating in the base of the tub.) Jot
your reading down.
5.
Go to the maintenance screen and hit
“Calibrate tub thermistor”
6.
When the calibration dialog box comes
up, tap on the number next to
Temperature Reading on HMI. Enter the
filling temperature that was shown on the
HMI when you measured the water
temperature.
7.
Press the number next to Measured
Temperature Reading and enter the value
you measured with your thermometer.
8.
Press OK to complete calibration.
9.
Steps 1-4 should be repeated to verify
that the calibration was successful. If the
displayed temperature and the measured
temperature are not in line, you will need
to repeat the procedure.
Calibrating Reservoir Thermistor:
1.
Ensure that the reservoir is empty before
beginning. Note: if you do not have a
temperature probe you can drop it into
the top of the tank then you will want to
ensure the tub thermistor is calibrated
before continuing.
2.
Go to the bathing screen and
press “Fill
Rapid Fill Reservoir” or “Disable Reservoir
Auto-
Fill” if the button is red.
3.
Let the reservoir tank fill to at least
halfway
. The reservoir tank’s temperature
probe is a bit slow to react, so it needs
some time to read.