Errors
Errors are displayed on the bottom of the maintenance screen and can be reset by hitting the “Reset
Error” button in the bottom right
-hand corner of the screen. Manual Reset errors need to be manually
reset under maintenance, Auto Reset errors will automatically clear once the offending conditions
have passed, and Auto/ Manual Reset errors automatically clear, but can be manually cleared as well.
The effects shown in the below table describe the features that are disabled until the error is reset.
Error List:
ID
Error as shown on screen.
Expanded explanation
Type [effect]
1
[Tilt Sensor Error]
Tilt sensor not detecting tub.
Verify tilt sensor is working
and adjusted appropriately
and ensure the actuator is
functioning.
Means tub was able to raise longer than expected
without hitting the upper limit. Likely causes are poor
positioning of the tilt limit switch and limit switch/ wiring
issue.
Manual Reset
[Disables tub
from tilting
upward]
2
[Res Drain Error]
Reservoir not draining. Verify
that the reservoir slide valve
opens and that the top float
sensor is working correctly.
Float switches still show the tank as full after the tank has
been draining for a while. Likely float sensor or slide valve
problem.
Manual Reset
[Disables Drain
Pump]
3
[Therm Fault]
Thermometer Fault. Please
ensure the thermometer is
connected properly.
Unlikely resistance value was measured from the
manifold thermometer. Likely caused by the
thermometer being disconnected or wired incorrectly.
Auto Reset
[Disables Valves]
4
[Temp Over Limit]
Temperature over the limit.
Verify Rada cartridge
adjusted appropriately.
Rada unable to bring the water temperature down into
an acceptable range. Could be caused by the cold-water
supply being turned off.
Auto/ Manual
Reset [Disables
Valves]
5
[Rada Home Fail]
Rada homing failed. Check
Rada limit sensor adjustment
and stepper motor
connection.
Rada limit never detected screw coming off of Rada.
Could be an issue with the inductive sensor or Rada
motor mount, wiring issue, stepper motor failure.
Manual Reset
[Disables Valves]
6
[Res Long Fill]
Reservoir taking too long to
fill. Verify correct operation of
top float sensor
Reservoir filling for a long time without top sensor being
triggered. This can be triggered if the plumbing does not
have adequate flow or if the water heater cannot keep up
resulting in a reduced flow. If this is the case, then adjust
the "Reservoir Max Fill Time" variable under "Timer
Adjustments" accordingly. Could also be a sensor/ wiring
failure.
Manual Reset
[Closes Reservoir
Fill]
7
[tub long fill]
Tub filling for too long. Verify
top water sensor is working
correctly.
The tub took significantly longer than expected to fill. Top
capacitive sensor likely the culprit. Check function/ wiring
or increase "Tub Max Fill Time" under "Timer
Adjustments" if the cause is slow plumbing.
Manual Reset
[Closes Tub Fill
Valve]