Page 8-165
10/2008
AMT/PTD/TR/0020/2/7/EN
8.6.3
F1/F2/F4 or F6/F2/F4 contiguous multi-site configuration
The slave PBXs must be synchronised via inter-site links (2.048 MHz clock).
The base stations must be wired in three pairs (F2 has no synchronization port + LD4/LDS,
LD4NX/LDS combination). The synchronization pair carries the 800 ms clock.
Note:
F2 has no synchronization ports; so for a multisite configuration between an F2-F4 fitted
with FPHBG/CSH or an F2-F4 fitted with FPHBG2/CSI/BCSI, the configuration of the
multisite synchronization is the same.
Note:
The LD4X (removing jumper J14 from an LD4NX card and offering additional functions)
is only compatible on the NeXspan S/L/D range and as of software release R4.1.
(1)
: use a repeater if there are more than 5 slave base stations
(2)
:even in an IP multi-site network, as the IP network is not synchronising, the PBXs must be
connected by a synchronising inter-site link.
Figure 7-19: F1/F2/F4 or F6/F2/F4 contiguous multi-site configuration
Synchronising
inter-site link
R
E
P
F2
L
D
S
F1
or
F6*
L
D
4
or
L
D
4
N
IP network
(2)
master base
slave base
slave base stations
800 ms clock synchro pairs
S0 bus
S0 bus
slave PBX
slave PBX
F4
L
D
S
or
L
D
T
master PBX
slave base stations
S0 bus
Synchronising
inter-site link
* on F6, base stations can be connected to the front panel of UCT-S cards.
L
D
4
X
Summary of Contents for X Series
Page 3: ......
Page 11: ...Page 1 11 10 2008 AMT PTD TR 0020 2 7 FR...
Page 63: ...Page 2 63 10 2008 AMT PTD TR 0020 2 7 EN...
Page 73: ...Page 3 73 10 2008 AMT PTD TR 0020 2 7 EN...
Page 77: ...Page 4 77 10 2008 AMT PTD TR 0020 2 7 EN Figure 4 2 Top view of the LD4 ST card...
Page 103: ...Page 4 103 10 2008 AMT PTD TR 0020 2 7 EN...
Page 105: ...Page 5 105 10 2008 AMT PTD TR 0020 2 7 EN...
Page 129: ...Page 6 129 10 2008 AMT PTD TR 0020 2 7 EN...
Page 171: ...Page 8 171 10 2008 AMT PTD TR 0020 2 7 EN...