Page 2: ...t is a registered trademark of Xerox Corporation Inc UNIX is a registered trademark in the United States and other countries licensed exclusively through The Open Group All other third party trademarks and registered trademarks are the property of their respective owners 2005 Aastra Technologies Limited All rights reserved Information in this document is subject to change without notice Aastra Tec...

Page 3: ...n x Compliances x Software licensing and copyright xi Welcome Introduction xiii What does the Aastra CNX do xiii What is in the Aastra CNX shipping package xiv Aastra CNX Installation and Setup Procedures Procedures 1 Introduction 1 Preparing for the hardware installation 2 Installing the Aastra CNX in a rack 3 Connecting to the console port 4 Connecting the network cables 5 Connecting the AC powe...

Page 4: ......

Page 5: ...urned to Aastra at the customer s sole expense Aastra shall repair or replace defective Products returned under Warranty at no charge to customer and Aastra shall bear the expense of the return shipment of the repaired or replacement Product to customer Aastra does not warrant the Product to be compatible with the equipment of any particular telephone company or their network This Warranty does no...

Page 6: ...If requested this number must be provided to the telephone company This Aastra CNX uses the following USOC RJ 48 jacks A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA A compliant telephone modular plug is provided with this product It is designed to be connected to a c...

Page 7: ... Canadian requirements Canadian Department of Communications Radio Interference Regulations This digital apparatus Aastra CNX does not exceed the Class A limits for radio noise emissions from digital apparatus as documented in the Radio Interference Regulations of the Canadian Department of Communications Règlement sur le brouillage radioélectrique du ministère des Communications Cet appareil numé...

Page 8: ...espectées Il n implique pas qu Industrie Canada a approuvé le matériel NOTE L étiquette du ministère des Communications du Canada indique que l appareillage est certifié c est à dire qu il respecte certaines exigences de sécurité et de fonctionnement visant les réseaux de télécommunications Le ministère ne garantit pas que l appareillage fonctionnera à la satisfaction de l utilisateur Avant d inst...

Page 9: ...of Council Directive 89 336 EEC Conformity is declared by the application of EN 55 022 1998 and EN 55 024 1998 WARNING This is a Class A product In a residential area this product may cause radio interference in which case the user may be required to take the appropriate measures EC declaration of conformity This product conforms to the provisions of Council Directive s EMC Directive 89 336 EEC Lo...

Page 10: ...not result in airflow blockage to power supply vents or chassis vents Before installing the Aastra CNX rackmount version ensure that the rack is sturdy and well secured Lithium battery caution CAUTION Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Discard used batteries according to the manufacturer s instruction...

Page 11: ... CNX product are deemed to be acceptance of the Software Licensing terms contained within the Aastra CNX Service Level Agreement Associated third party license agreements and applicable Open Source software licenses are incorporated by reference the full text of all licenses can be found on the Aastra CNX documentation CDROM The following is a list of Aastra CNX software licenses See the Aastra CN...

Page 12: ......

Page 13: ...rovides High quality voice conferences for up to 30 participants in up to 15 active conferences upgradable to 60 participants and 30 active conferences or 120 participants and 60 active conferences Allows for permanent and scheduled conferences Comprehensive conference controls for host and participants using a simple touch tone telephony interface Simple to install configure manage and use throug...

Page 14: ...unit for use in CompactFlash memory slot 1 One set of rack mounting brackets with six Phillips head screws One Aastra CNX Technical Documentation CD ROM One CD ROM envelope with License Key label For a list of additional parts that you need to install the Aastra CNX which are not included in the shipping package see the section Aastra CNX Installation and Setup Procedures on page 1 Aastra CNX unit...

Page 15: ...n and setup procedures for installing and starting up the Aastra CNX Conference Network Switch This section also provides a list of additional parts that you need to install the Aastra CNX References For information about configuring and using the Aastra CNX see related documentation on the Aastra CNX Conference Network Switch Documentation CD ...

Page 16: ...e DB 9 to female DB 25 RS 232 serial cable for modem connections not provided Prepare for hardware installation 1 Check the shipping contents Upon opening the shipping package inventory the contents to be sure there are no missing or damaged parts as described in the Welcome section of this document Determine location of Aastra CNX desktop or rackmount a If you are installing the Aastra CNX as a d...

Page 17: ...ment must provide unobstructed front to back airflow to the chassis mounted in a rack a Mount the rackmount brackets to the Aastra CNX unit in a flush mount position using the 6 Phillips head screws b Align the bracket holes to the rack and insert truss head screws not provided c Tighten the screws to 15 in lb 69 Nm To install an Aastra CNX in a rack Install the Aastra CNX in a rack 2 CNX POWER ST...

Page 18: ...the PC and the other end to a LAN port b Attach one end of an Ethernet cable to an Ethernet port on the back panel of the Aastra CNX and the other end to a LAN port To connect a modem a Attach the 9 pin male connector on the serial cable to the female console port on the rear panel of the Aastra CNX b Attach a 25 pin male connector on the modem cable to the modem s DB 25 RS 232 port Local connecti...

Page 19: ... of the Aastra CNX Ethernet Connect the RJ 45 Ethernet UTP cable s to the RJ 45 10 100 ENET port s on the rear panel of the Aastra CNX Make sure you have the network cables that you need for your facility and connect them to the following interfaces as appropriate Connect network cables 4 Ethernet RJ 45 connectors T1 E1 RJ 48C connectors CONSOLE 10 100 ENET RESET T1 E1 1 2 4 3 2 1 100 240VAC 1 0A ...

Page 20: ...e 3 prong connector on the power cable into the power receptacle c Insert the plug at the other end of the power cable into a grounded power source 100 to 240 VAC Connect the power cable 5 AC power cord Connect to a grounded 15 A power source 100 to 240 VAC North America 120 V at 15 A Europe 240 V at 10 A NOTE North America 120 V at 15 A Europe 240 V at 10 A CONSOLE 10 100 ENET RESET T1 E1 1 2 4 3...

Page 21: ...tion at bootup b When the T1 E1 port s are enabled check that the T1 E1 LEDs on the bottom row are OFF If the T1 E1 LED s on the bottom row are ON Amber a yellow alarm is present on the T1 E1 link If the T1 E1 LEDs are ON Red a Red alarm is present on the T1 E1 link Contact your System Administrator Check the LEDs a Check the common LEDs on the front panel The Power and Status LEDs should be ON gr...

Page 22: ...etwork interface via the Ethernet port s The Aastra CNX must be turned on You must be running a terminal emulator on your PC Terminal emulator must be set as follows Baud Rate 9600 Data 8 bit Parity None Stop 1 bit Flow Control None The Aastra CNX setup script allows you to configure the following 1 Run network and time configuration The following procedure describes how to configure the network s...

Page 23: ...ity please press enter to continue 2 Press Enter The following displays Hostname 3 Enter the hostname for the Aastra CNX and press Enter For example Hostname cnx1 The following displays Configuring ENET 1 IP Address 4 Enter the IP address for the Ethernet port for which you want to use as a management interface and press Enter For example IP Address 192 168 2 6 The following displays Netmask 5 Ent...

Page 24: ...a management interface and press Enter For example Default Gateway 192 168 2 1 The following displays Before the following information is configured please verify the information below is correct before proceeding Hostname cnx1 IP Address 192 168 2 6 Broadcast Address 192 168 2 255 Netmask 255 255 255 0 Default Gateway 192 168 2 1 Is this correct y n 8 Enter y if the network information is correct...

Page 25: ... 1 Nameserver 2 10 Enter the IP address of the DNS servers for the Aastra CNX and press Enter For example Nameserver 1 192 167 2 11 Nameserver 2 192 168 2 12 The following message and prompts display Before the following information is configured please verify the information below is correct before proceeding Domain Name aastra com Nameserver 1 192 167 2 11 Nameserver 2 192 168 2 12 Is this corre...

Page 26: ...ein PST8PDT Universal Arctic EST GMT0 Libya Pacific W SU Asia EST5EDT Greenwich MET Poland WET Atlantic Egypt HST MST Portugal Zulu Australia Eire Hongkong MST7MDT ROC Brazil Etc Iceland Mexico ROK CET Europe Indian Mideast Singapore CST6CDT GB Iran NZ Turkey Canada GB Eire Israel NZ CHAT UCT Enter a choice back to go up one level or cancel to cancel 12 Enter your local timezone and press Enter Fo...

Page 27: ... year 2005 Month 03 Day 09 Hour 19 Minutes 40 14 The defaults for the date and time are the current date and time on your PC If these defaults are correct press Enter at each prompt without making an entry If a default is incorrect enter the correct value and press Enter to continue In the following example 14 is entered for the hour since the default of 19 is incorrect Four digit year 2005 Month ...

Page 28: ...then enter y at step 15 The following message displays after entering y at the verification prompt Configuring Network Time Protocol NTP You can configure up to 4 NTP servers To remove an existing server set it s address to 0 0 0 0 If no valid servers are given then ntp will be disabled Do you want to continue y n n 16 Enter y to continue and press Enter The following prompts display NTP Server 1 ...

Page 29: ...ra CNX However you may completely disable the NTP server feature by setting the IP address of all four servers to 0 0 0 0 The following displays Before the following information is configured please verify the information below is correct before proceeding NTP Server 1 192 167 2 11 NTP Server 2 192 167 2 12 Is this information correct y n n 18 Enter y if the NTP information is correct and press En...

Page 30: ... System Administrators is cnxadmin c Enter the Aastra CNX License Key and click APPLY The License Key can be found on the label located on the Documentation CD ROM envelope The Aastra CNX reboots Close your web browser and wait a few minutes before logging in again d Repeat steps a and b when the reboot is complete e Change the default password by clicking the Change Password button f Configure th...