Identification elements
101
System functions and features as of R3.0
syd-0367/1.3 – R3.0 – 03.2013
4. 7. 2
Outgoing Calls to the Public Network
Call to the Public Network via a Gateway PINX
User C (340) on PINX 2 calls user F on the public network via PINX 1.
PINX 1 has a DDI number for user C (54).
The following CLIP characteristics are set in the trunk group configuration of
PINX 1:
•
CLIP number
= 50
•
NPI
=
unknown
•
TON
=
unknown
Fig. 38
Example 3: User C calls user F in the public network (excerpt from
)
Tab. 27
Example 3: Creating and presenting user C’s CLIP number
Step
CLIP number
NPI
TON
Description
1
340
PNP
level 0
User C
→
PINX 2
• There is no suitable DDI number.
2
50340
PNP
level 1
PINX 2
→
PINX 1
3
340
PNP
level 0
PINX 1
• The system’s own regional prefix is deleted
• TON is adapted.
4
54
Unknown
Unknown
PINX 1
→
Exchange
• There is a suitable DDI number, which is used as a
CLIP No. and sent to the public network.
5
055 555 55 54
Exchange
→
User F
• Presentation on the terminal