background image

Wireless Automatic

Blood Pressure Monitor

Multilingual Instruction Guide - Model UA-851ANT

   

English  •  Français  •  Español

Summary of Contents for UA-851ANT

Page 1: ...Wireless Automatic Blood Pressure Monitor Multilingual Instruction Guide Model UA 851ANT English Fran ais Espa ol...

Page 2: ......

Page 3: ...ith water and a mild detergent Never use alcohol benzene thinner or other harsh chemicals to clean monitor or cuff Remove and replace batteries if monitor is not used for more than six months Alkaline...

Page 4: ...he UA 851ANT will effortlessly integrate blood pressure into your daily wellness regimen We recommend that you read through this manual carefully before using the device for the first time A D Medical...

Page 5: ...HE CUFF TO THE MONITOR E 6 TAKING YOUR BLOOD PRESSURE E 6 HOW THE UA 851ANT WORKS E 8 ABOUT CUFF INFLATION METER E 8 WHAT IS AN IRREGULAR HEARTBEAT E 9 USING THE OPTIONAL AC ADAPTER E 10 ABOUT BLOOD P...

Page 6: ...r heartbeats The battery power indicator is displayed during measurement The batteries are low when it blinks Unstable blood pressure due to excessive body movement The systolic and diastolic values a...

Page 7: ...IGITAL BLOOD PRESSURE MONITOR MONITOR COMPONENTS Display START Button Air Socket Air Connector Plug Air Hose Arm Cuff Battery Compartment Battery Cover FRONT AC Adapter Jack Optional AC Adapter BACK S...

Page 8: ...ment with positive and negative terminals matching those indicated in the compartment Be sure batteries make contact with compartment terminals 3 Replace cover by sliding it into the compartment and g...

Page 9: ...ff UA 280 14 2 17 7 36 45cm Large Cuff UA 281 Cuff Size Indicator On The Cuff Our cuff has an indicator which tells you whether you are using the correct cuff size or not Place the cuff on your arm se...

Page 10: ...ement Now you are ready Follow these simple steps 1 Sit comfortably with your left arm resting on a flat surface so that the center of your upper arm is at the same height as your heart After installi...

Page 11: ...f you wish to stop inflation at any time press the START button again 6 When the measurement is complete the systolic and diastolic pressure readings and pulse rate are displayed The cuff deflates and...

Page 12: ...readouts Our technology is based on the oscillometric method a noninvasive blood pressure determination The term oscillation refers to any measure of vibrations caused by the arterial pulse Our monito...

Page 13: ...irregular heartbeat is defined as a heartbeat that varies by 25 from the average of all heartbeat intervals during the blood pressure measurement It is important that you relax remain still and refra...

Page 14: ...C outlet 2 Connect the AC adapter plug into the jack on the back of the monitor Disconnecting the AC adapter from the monitor 1 Turn the unit off by pressing the START button 2 Disconnect the plug fro...

Page 15: ...ing will likely raise an individual s blood pressure Sleeping will likely decrease blood pressure Not relaxing for several moments before measurements can influence readings as well In addition to the...

Page 16: ...rtension 120 139 or 80 89 Stage 1 Hypertension 140 159 or 90 99 Stage 2 Hypertension 160 or 100 SOURCE The Seventh Report of the Joint National Committee on Prevention Evaluation and Treatment of High...

Page 17: ...lifestyle suggestions to prevent or control hypertension Don t smoke Have regular physical checkups Reduce salt and fat intake Maintain proper weight Monitor your blood Exercise routinely pressure at...

Page 18: ...tical for the accuracy of the measurement This may give you a different reading A cuff too large will produce a reading that is lower than the correct blood pressure a cuff that is too small will prod...

Page 19: ...f day in the same location sitting in the same chair using the same cuff etc Once you establish your baseline measurement you can start evaluating if your measurement has been affected by factors such...

Page 20: ...nt The cuff position is not correct You are using the wrong size cuff The healthcare professional may be using a different sized cuff Your measurements may be elevated by white coat hyper tension Repl...

Page 21: ...one daily measurement Recommended operating 50 F to 104 F 10 C to 40 C environment Less than 85 relative humidity Recommended storage environment 14 F to 140 F 10 C to 60 C Less than 95 relative humid...

Page 22: ...e to ensure that the information in this manual is accurate A D Medical is not responsible for printing or clerical errors These devices comply with Part 15 of the FCC Rules Operation is subject to th...

Page 23: ...A division of A D Engineering Inc 1756 Automation Parkway San Jose CA 95131 2010 A D MEDICAL ALL RIGHTS RESERVED SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE PRINTED IN CHINA I MAN UA851ANT 4 10...

Page 24: ...Tensiom tre automatique sans fil Tensiom tre Mode d emploi plurilingue Mod le UA 851ANT Anglais Fran ais Espagnol...

Page 25: ...e jamais utiliser de l alcool du benz ne du diluant ou d autres produits chimiques puissants pour nettoyer le tensiom tre ou le brassard Retirer et remplacer les piles si le tensiom tre est inutilis p...

Page 26: ...ffort la tension art rielle dans votre r gime quotidien de sant Licez ce manuel en entier soigneusement avant d utiliser l appareil pour la premi re fois A D Medical fabrique des produits pour les soi...

Page 27: ...U TENSIOM TRE F 6 PRENDRE LA TENSION ART RIELLE F 6 FONCTIONNEMENT DU UA 851ANT F 8 INDICATEUR DE GONFLAGE DU BRASSARD F 8 QU EST CE QU UNE ARYTHMIE F 9 UTILISATION DE ADAPTATEUR CA EN OPTION F 10 REN...

Page 28: ...ements concernant les arythmies Le symbole de la puissance des piles s affiche pendant la mesure Les piles sont faibles lorsque le sym bole clignote Tension art rielle instable suite des mouvements co...

Page 29: ...PI CES DU TENSIOM TRE cran Bouton de mise en marche START Prise d air Fiche d air Tube d air Brassard Compartiment piles Couvercle du compartiment piles AVANT Prise pour l adaptateur CA Adaptateur CA...

Page 30: ...rnes positive et n gative avec les inscriptions S assurer que les piles entrent en contact avec les bornes du compartiment 3 Replacer le couvercle en le glissant dans le compartiment et l enfon ant d...

Page 31: ...rd Notre brassard comporte un indicateur qui vous montre si vous utilisez la taille de brassard appropri e Fixer le brassard votre bras consulter la page E 6 pour conna tre la bonne m thode de fixatio...

Page 32: ...jambes et garder les pieds plat sur le plancher pendant la mesure Vous tes maintenant pr t Proc der comme suit 1 S asseoir confortablement le bras gauche appuy sur une surface plane de sorte que le ce...

Page 33: ...ation recommence automatiquement Remarque Appuyer tout moment sur le bouton de mise en marche START pour cesser le gonflage 6 la fin de la mesure les lectures de tensions systolique et diastolique ain...

Page 34: ...oscilloscope une mesure non invasive de la tension art rielle L expression oscillation se r f re toute mesure des vibrations produites par le pouls art riel Notre tensiom tre analyse la pression prod...

Page 35: ...irr gulier est un rythme qui varie de 25 par rapport la moyenne de tous les rythmes cardiaques pendant la mesure de la tension art rielle Il est important d tre d tendu sans bouger et d viter de parle...

Page 36: ...volts CA 2 Connect the AC adapter plug into the jack on the back of the monitor D connexion de l adaptateur CA du tensiom tre 1 teindre l appareil en appuyant sur le bouton de mise en marche START 2 D...

Page 37: ...Marcher peut augmenter la tension art rielle Dormir peut diminuer la tension art rielle Prendre sa tension art rielle sans attendre plusieurs minutes entre les lectures peut galement influencer les r...

Page 38: ...e 120 et 80 Pr hypertension 120 139 ou 80 89 Hypertension niveau 1 140 159 ou 90 99 Hypertension niveau 2 160 ou 100 SOURCE The Seventh Report of the Joint National Committee on Prevention Evaluation...

Page 39: ...cernant le style de vie pour viter ou contr ler l hypertension viter le tabagisme Subir des examens physiques p riodiquement R duire la consommation de sel et de lipides Maintenir un poids sant Survei...

Page 40: ...la pr cision de la lecture Cela peut aussi vous donner une lecture diff rente Un brassard trop grand donnera une lecture plus basse que la tension art rielle exacte alors qu un brassard trop petit fo...

Page 41: ...au m me endroit dans la m me chaise au moyen du m me brassard etc Une fois la mesure de r f rence tablie vous pouvez commencer valuer si votre lecture est influenc e par des facteurs comme des modific...

Page 42: ...Vous utilisez un brassard de la mauvaise taille Il se peut que le professionnel de la sant utilise un brassard de taille diff rente Il se peut que la lecture soit lev e cause du syndrome de la blouse...

Page 43: ...mois si utilis es une fois par jour Conditions d exploitation 10 C 40 C 50 F 104 F Moins de 85 d humidit relative Temp ratures de rangement 10 C 60 C 14 F 140 F Moins de 95 d humidit relative Dimensi...

Page 44: ...nt dans ce manuel sont exacts A D Medical n assume aucune responsabilit pour les erreurs d impression ou de r daction Ces appareils sont conformes au paragraphe 15 du r glement de la FCC Le fonctionne...

Page 45: ...A D Company Ltd 1 243 Asahi Kitamoto shi Saitama 364 8585 JAPON 2010 A D MEDICAL TOUS DROITS R SERV S LES SP CIFICATIONS PEUVENT CHANGER SANS PR AVIS IMPRIM EN CHINE I MAN UA851ANT 4 10...

Page 46: ...Monitor autom tico inal mbrico de presi n arterial Monitor de presi n arterial Gu a de instrucciones pluriling e Modelo UA 851ANT English Fran ais Espa ol...

Page 47: ...te suave Nunca limpie el monitor o el brazalete con alcohol bencina solvente ni otros productos qu micos agresivos Retire y reemplace las pilas si el monitor no se utiliza durante m s de seis meses Se...

Page 48: ...ayor esfuerzo sus lecturas de presi n arterial en su r gimen diario de bienestar personal Se recomienda leer este manuel de instrucciones detenidamente antes de usario por primera vez A D Medical tien...

Page 49: ...DICI N DE LA PRESI N ARTERIAL S 5 C MO FUNCIONA EL UA 851ANT S 7 ACERCA DEL MEDIDOR DE INGRESO DE AIRE EN EL BRAZALETE S 7 QU ES UN LATIDO IRREGULAR DEL CORAZ N S 8 UTILIZACI N DEL ADAPTADOR DE CA OPT...

Page 50: ......

Page 51: ...sulte la p gina E 8 para conocer m s informaci n sobre pulsos irregulares El indicador de carga de la pila se muestra durante la medici n Las pilas tienen poca carga cuando parpadea La presi n arteria...

Page 52: ...TES DEL MONITOR Pantalla Bot n de inicio START Toma de aire Conector para suministro de aire Manguera de aire Brazalete Compartimiento para pilas Tapa para pilas FRENTE Toma para adaptador de CA Adapt...

Page 53: ...oque las pilas haciendo coincidir los terminales positivo y negativo con los indicados en el compartimiento Aseg rese de que las pilas hagan contacto con los terminales del compartimiento 3 Coloque nu...

Page 54: ...de UA 281 Indicador de tama o en el brazalete Nuestro brazalete tiene un indicador que dice si est usando el tama o correcto de brazalete o no Col quese el brazalete en el brazo vea la p gina E 6 para...

Page 55: ...ora est listo Siga estos simples pasos 1 Si ntese c modo con el brazo izquierdo apoyado en una superficie plana de modo que el centro de la parte superior del brazo quede a la misma altura que el cora...

Page 56: ...mente a inflar el brazalete otra vez Nota Si desea detener el ingreso de aire en cualquier momento presione nuevamente el bot n de inicio 6 Cuando la medici n finaliza en la pantalla aparecen las lect...

Page 57: ...de mediciones Nuestra tecnolog a se basa en el m todo de medici n de la oscilaci n una determinaci n no invasiva de la presi n arterial El t rmino oscilaci n se refiere a cualquier medici n de vibrac...

Page 58: ...indicador muestra un segmento basado en la medici n del momento correspondiente a la clasificaci n JNC7 NOTA A causa de otros factores de riesgo por ejemplo diabetes obesidad tabaquismo etc adem s de...

Page 59: ...en un tomacorriente de CA de 120V 2 Conecte el enchufe del adaptador de CA en la toma situada al dorso del monitor Para desconectar el adaptador de CA del monitor 1 Apague la unidad presionando el bot...

Page 60: ...os Dormir puede bajar la presi n en los individuos No descansar or relajarse por algunos momentos antes de tomarse la presi n arterial puede influenciar sus lecturas tambi n Adem s de estos factores l...

Page 61: ...si n 120 139 o 80 89 Hipertensi n en etapa 1 140 159 o 90 99 Hipertensi n en etapa 2 160 o 100 FUENTE El S ptimo Informe del Comit Nacional Conjunto sobre Prevenci n Evaluaci n y Tratamiento de Hipert...

Page 62: ...n recomienda las siguientes sugerencias en cuanto al estilo de vida para evitar o controlar la hipertensi n No fume H gase ex menes m dicos peri dicos Reduzca el consumo de sal y grasas Mantenga un pe...

Page 63: ...es fundamental para que la medici n sea precisa Esto puede arrojar una lectura diferente Un brazalete demasiado grande producir una lectura menor que la presi n arterial correcta uno demasiado peque o...

Page 64: ...mismo lugar sentado en el mismo asiento utilizando el mismo brazalete etc Una vez que establezca la medici n de referencia podr comenzar a evaluar si la medici n ha sido afectada por factores tales co...

Page 65: ...lete no es la correcta Est usando un tama o incorrecto de brazalete Es posible que el profesional haya utilizado un brazalete de tama o distinto Es posible que las mediciones sean elevadas por la hipe...

Page 66: ...diaria Condiciones del ambiente para funcionamiento Entre 50 F y 104 F entre 10 C y 40 C Humedad relativa de menos del 85 Condiciones del ambiente para almacenamiento Entre 14 F y 140 F entre 10 C y 6...

Page 67: ...correcta A D Medical no se hace responsable de errores administrativos o de impresi n Estos dispositivos cumplen con la Parte 15 de las Reglas de la Comisi n Federal de Comunicaciones FCC El funciona...

Page 68: ...ompany Ltd 1 243 Asahi Kitamoto shi Saitama 364 8585 JAP N 2010 A D MEDICAL RESERVADOS TODOS LOS DERECHOS SLAS ESPECIFICACIONES EST N SUJETAS A CAMBIOS SIN PREVIO AVISO IMPRESO EN CHINA I MAN UA851ANT...

Page 69: ...A D Company Ltd 1 243 Asahi Kitamoto shi Saitama 364 8585 JAPAN 2010 A D MEDICAL ALL RIGHTS RESERVED SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE PRINTED IN CHINA I MAN UA851ANT 4 10...

Reviews: