HVG-WP Series
Page 47
Item
Display Description
f8 5
At each finish of the full/dribble batch function, the scale
accumulates the data automatically.
Use Packing articles like a powder. used for recording the bag
number and total mass.
A
Select the details of the full/dribble batch function (
f6 9
)
A
f10 0
#
When the
F
key is pressed after final value is reached, the
current process is finished.
A
A
f10 1
When the stability mark is displayed after final value is reached,
the current process is finished.
A
A
f10 2
When the
SET
key is pressed, the scale automatically tares and
starts the full/dribble batch process. When the
F
key is pressed
after final value is reached, the current process is finished.
A
A
A
Full/Dribble
batch sub-
function
f10 3
When the
SET
key is pressed, the scale automatically tares and
starts the full/dribble batch process. When the stability mark is
displayed after final value is reached, the current process is
finished.
A
A
A
Select the address for RS-422 / RS-485 for option OP-04
A
Address
f11 1
#
~
f11 99
Use addresses from 01 to 99 are available. Scales are assigned
unique addresses and are controlled by the computer.
(RS-232C should be set to "
00
".)
A
A
A
Select the method to hold the current weight value. When the
weight value becomes nearly-zero or changes more than more
than 25% +30 digits, hold display is canceled.
A
A
A
f12 0
# Not used
A
f12 1
The hold function is ON or OFF alternately by the
F
key.
A
Hold
f12 2
When the stability mark is displayed, the display is held.
A
Select readability and response
A
f13 0
#
A
f13 1
A
Averaging
f13 2
Fast response, sensitive value.
c
Slow response, stable value.
A
Select a storable minimum unit mass in the counting mode.
A
f14 0
# Stores a unit mass in the unit of a digit.
A
f14 1
Stores a unit mass in the unit of one-eighth digit.
A
Precision
of unit
mass
f14 2
Stores a unit mass, if the total of the sample mass is greater than
5 digits.
A
A
Refer to "16.1. Data Format".
A
f15 0
# Format 1. (A&D general format for scales, balances)
A
Format
f15 1
Format 2. (Older HV-A/ HW-A format)
A
f16
Not used.
A
"#"
factory
settings
The "nearly-zero" is within
±
4 digits from zero point in the unit of kg.
The "digit", a unit of display, is equivalent to the minimum measurable mass.
Summary of Contents for HV-60KGL-WP
Page 68: ...Page 66 HVG WP Series Dimensions 390 743 530 110 150 70 440 9 6 60 45 45 300 ...
Page 70: ... Blank page ...
Page 71: ......