background image

P-3/4 

AD-8920 REMOTE DISPLAY INSTRUCTION MANUAL

 

(日本語の取扱説明書は反対面をご覧ください。)

 

1. Introduction 

The AD-8920 is a remote display that uses vacuum fluorescent display technology. It displays the weighing 

data transmitted by an A&D manufactured weighing instrument using RS-232C or current loop. Applicable 

weighing instruments (electronic balances/platform scales) are listed below. When the output connector of the 

weighing instrument is of the DIN type, an optional DIN conversion cable is required.   

 

„

 What the package contains 

Table 1 Applicable instruments and required options (As of August, 2007)

 

AD-8920 main unit

 

Using RS-232C   

Using current loop 

Communication cable (Approx. 1 m) 

Weighing 

instrument On instrument

On AD-8920 

On instrument

On AD-8920

AC adapter

 

AD-4212A/B

None (D-SUB25)

None Not 

applicable 

   

EK-G,EW-G

OP-03(D-SUB25)

None OP-05(DIN7)  OP-01 

 

EK-H OP-03H(D-SUB25)

None

 

OP-05H(DIN7)

OP-01

 

EK-i,EW-i

None (D-SUB9)

None

Not applicable

Instruction manual (this leaflet) 

ET-W OP-03W(D-SUB25)

None

 

OP-05W(DIN7)

OP-01

FC-i

None (D-SUB9)

None

 

Not applicable

 

FG

OP-03(DIN7)

OP-01

 

OP-05(DIN7) OP-01

„

 Options (Sold separately)

 

FG-M/L

OP-23(DIN8)

OP-01

Not applicable

OP-01

 

DIN conversion cable

 

 

(Approx. 25 cm)

 

FP OP-03(D-SUB25)

None 

OP-03 or   
OP-04(DIN7) 

OP-01 

 

FS

OP-03(DIN7)

OP-01

 

Not applicable

 

FX-i

None (D-SUB9)

None

 

Not applicable

„

 Connection diagram

 

GH,HR-i

None (D-SUB9)

None

Not applicable

 

GR  

None

 

(D-SUB25)

None

 

Not applicable

 

 
 

GX,GF, GP,
GX-K

None

 

(D-SUB25)

None

 

OP-04 or   
OP-06(DIN7) 

OP-01 

 

HA-M

OP-03(D-SUB25)

None

 

OP-03(DIN7) OP-01

 
 

HA-A OP-03(D-SUB25)

None

 

OP-03 or   
OP-04(DIN7)

 

OP-01

 

 

HC-i

OP-03(DIN8)

OP-01

Not applicable

 
 

HF,HM OP-03(D-SUB25)

None

 

OP-03 or   
OP-05(DIN7)

 

OP-01 

 

 
 
 

HP OP-03(D-SUB25)

None

 

Either one of 
OP-03,OP-04, 
OP-05,OP-06, 
(DIN7)

 

OP-01 

 
 

HR OP-03(D-SUB25)

None

 

OP-03 or   
OP-05(DIN7)

 

OP-01 

 
 

HV-G  
HW-G 

None (DIN8) 

OP-01

 

Not applicable

 

 
 

HX None 

(D-SUB25)

None

 

OP-04 or   
OP-05(DIN7)

 

OP-01

 

2. Preparation

 

2-1. Setting the weighing instrument 

Table 2 List of instrument settings 

Item Setting 

Description 

Data output mode  Stream mode 

Outputs the weighing data continuously. 

Baud rate 

2400bps or 600bps

 

AD-8920 recognizes the baud rate automatically.

Length, Parity bit 

7 bits-even, 7 bits-odd, or 8 bits-none

AD-8920 functions correctly with any one of those listed.

Stop bits 

1 bit or 2 bits 

AD-8920 functions correctly with either one. 

Terminator 

<CR> or <CR><LF>

 

AD-8920 functions correctly with either one.

 

Data format 

A&D standard format 

CTS control 

No control of CTS, RTS

Output (hardware)  RS-232C or current loop

AD-8920 recognizes the output mode automatically.

 

 

Note) The available items depend on the weighing instrument. (An item is not available when the setting is fixed.) 

 

 

 For a detailed description of the settings, refer to the instruction manual of each weighing instrument. 

2-2. Connecting the AD-8920 

1.Confirm that the AC adapter is of the correct type. 2.Refer to the Table1 shown above to connect the 

communication cable correctly. Use the OP-01 DIN conversion cable when the output connector on the 

weighing instrument is of the DIN type. 3.Refer to the connecting diagram shown above to connect the 

AD-8920 to the weighing instrument by the communication cable.   

 

D-SUB9/D-SUB25 output

Weighing

instrument

Communication cable

AC adapter

AD-8920 main unit

1WMPD4000178C