A&D AD-4401A Instruction Manual Download Page 1

 

 

 

 

-1-

 

-2-

 

-3-

-4-

 

 

No.

Name

 

1

Main

 

2

Sub

 

Numerical 
Display

 

3

Unit

 

Status Dis- 
play (Upper)

 

4

ZERO / STABLE (MD: Motion detection) / GROSS / NET / HOLD / 
FUNCTION            / ALARM 

Normal batching

 

Loss-in-weight batching

 

Check weighing

 

Status 
Display 
(Lower)

 

5

Final weight / Free fall / 
Preliminary / Optional 
preliminary / Overweight / 
Underweight / Near-zero   

Final weight / Free fall / 
Preliminary / Full / 
Overweight / 
Underweight / Near-zero

Near-zero / Lo-Lo /   
Lo / Go / Hi / Hi-Hi 

6

CAL (Calibration) key 

Key 
Switches

 

7

SETPOINT: Sets the setpoint values for batch weighing and check weighing.

 

ZERO: Sets the gross value to zero when the weight value is within the zero 

setting range. (Default zero setting range: 2% of maximum capacity)

 

TARE:

 

Saves the current gross value as tare and sets the net value to zero.

 

NET/GROSS: Selects the weight value display method, gross or net.

 

Function: No function is assigned in the default setting.

 

ENTER:

 

Does not function alone.

 

ON/OFF:

 

Turns the display on or off.

 

8

 

Rating label (Accessory)

 

Other

 

9

 

Sealing cover

 

*

 Attach the accessory status label when performing loss-in-weight batching or check weighing.

 

 

2.2. 

Rear Panel 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

 

Name

 

No.

 

Name

 

SETPOINT input connector 

Optional analog 4-20 mA output terminal block 

CONTROL I/O connector 

AC power input terminal block

 

SER.OUT 
(Standard serial output) connector 

Protective conductor terminal

 

Option slot 

Slide rail

 

Load cell input terminal block 

 

 

2.3. 

Accessories

 

 

Name 

Qty. 

Name 

Qty. 

Terminal block cover 

Panel mount packing 

Terminal block cover securing screw 

Rubber foot 

Connector for the CONTROL I/O 

Rating label 

Connector for the SER.OUT 

Status label 

 

3. 

INSTALLATION TO CONTROL PANEL

 

Make a hole in a control panel as shown below.

 

 

 

 

 

Unit: mm 

Remove the slide rails on both sides and 
insert the AD-4401A with the accessory 
packing through the hole into the panel.

 

 

 

 

 

 

 

Insert the slide rails from behind.

 

 

 

 

 

 

 

 

AD-4401A 
Weighing Indicator 

Simplified Instruction Manual 

 

 

 

This manual is a simplified version of the instruction manual. 
When using the indicator, please read the AD-4401A Weighing 
Indicator Instruction Manual which is available on our website. 
Download the latest complete instruction manual at:   

URL: http://www.aandd.co.jp/

 

 

No part of this publication may be reproduced, transmitted, 
transcribed, or translated into any other language in any form by any 
means without the written permission of A&D Company, Limited.

 

 

The contents of this manual and the specifications of the instrument 
covered by this manual are subject to change for improvement without 
notice. 

 

 

2015 

  All rights reserved. 

3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013, JAPAN 

Telephone: [81] (3) 5391-6132 
Fax: [81] (3) 5391-6148 

1WMPD4003052 

 
 

1. 

SAFETY PRECAUTIONS 

Read the following precautions carefully before using the indicator.

 

 

[

Precautions for designing]

 

 

 

WARNING

 

 

Provide an external safety circuit to the indicator so that the safety of the whole system 
can be secured even if errors occur in the external power supply or in the indicator.

 

 

[

Precautions for installation]

 

 

 

WARNING

 

 

Do not use the indicator in the following environments:

 

- where the temperature and the humidity exceed the specifications

 

- where corrosive gases or flammable gases exist

 

- where the indicator gets wet with oil, chemicals or water 

Please note that securing the indicator to the control panel will provide the 
indicator outside of the control panel with IP65 protection.

 

 

When installing or removing the indicator, be sure to turn off all used external 
power supplies beforehand.

 

 

[

Precautions for wiring]

 

 

 

WARNING

 

 

When wiring the indicator, be sure to turn off all used external power supplies 
beforehand.

 

 

When wiring is complete, be sure to attach the terminal block cover provided 
with the indicator.

 

 

Be sure to earth ground the indicator.

 

 

 

 

CAUTION

 

 

Do not clamp control wires or communication cables with power lines or place 
them close to power lines.

 

 

Place the load cell cable sufficiently away from high frequency circuits such as 
high voltage power lines and inverter load circuits.

 

 

2. 

PART NAMES

 

2.1. 

Front Panel

 

 

 

 

 

 

 

 

       

         

         

         

6.2. 

Calibration Using Calibration Weights 

Press the CAL key in the normal mode.

 

 

When “

Cal

" is displayed, press the ENTER key.

 

 

When “

Cal 5et

” is displayed, press the ENTER 

key.

 

Zero calibration

 

Press the ENTER key when the STABLE (MD) 

status is turned OFF. 

 

When the Function key is pressed, the AD-4401A 

proceeds to span calibration without performing 

zero calibration.

 

Dashes are displayed in the sub-display and zero 

calibration is performed.

 

Span calibration

 

Set the calibration weight value in the sub-display. 

Press the ENTER key when the STABLE (MD) 

status is turned OFF. 

Dashes are displayed in the sub-display and span 

calibration is performed. 

 

Press the ON/OFF key twice to return to the normal 

mode. 

 

7. 

FUNCTIONS 

When the AD-4401A is powered ON, all the segments of the display turn ON and OFF 
to check the display. Then the AD-4401A enters the normal mode and starts weighing. 
If the AD-4401A is powered OFF during the OFF mode (with the display OFF), 
the AD-4401A will be in the OFF mode when powered ON. 

 

7.1. 

Control I/O 

 

 

 

 

 

 

The applicable connector is an FCN-360 series 16-pin female connector 
manufactured by Fujitsu Component Limited or the equivalent. An FCN-361J016 
(connector) and an FCN-360C016 (cover) are provided with the indicator.

 

Pin No. 

Description 

Description 

Pin No.

A1 Zero 

setting  Input 

Near-zero 

Output  B1 

A2 Tare 

Input Underweight, 

Hi-Hi 

 

Output  B2 

A3 Weighing 

start Input 

OK, 

Hi 

Output  B3 

A4 

Emergency stop  Input 

Large flow, Full, Go    Output 

B4 

A5 

Discharge start 

Input 

Medium flow, Lo 

Output 

B5 

A6 

Key lock 

Input  Small flow, Lo-Lo    Output 

B6 

A7 Input 

common 

Discharge 

Output  B7 

A8 Output 

common 

Weighing 

end  Output  B8 

The above are the default settings. Assigned functions can be changed for each pin.

 

 

Connection Diagram 

 

 

 

 

 

 

 

 

 

Control input

 

-  ON voltage: 5 V or less 
-  ON current: 3 mA or more
-  OFF current: 1 mA or less

 

 

 

 

 

 

 

 

 

Control output

 

-  Maximum load voltage: 30 VDC
-  Maximum load current:: 50 mA/point 
-  Voltage drop at ON: 1 V or less 

-   Leakage current at OFF: 0.1 mA 

or less

 

4.

CONNECTION TO POWER SUPPLY 

 

Terminal No.

 

Symbol

 

Description

 

11 

 

 

Ground terminal

 

12 

AC power input (Neutral) Earthed conductive part

 

13 

 

 

AC power input (Live) Unearthed conductive part

 

 

 

 

 

 

 

 

5. 

CONNECTION TO LOAD CELL 

 

TML No. Symbol

 

Description

 

EXC+  Load cell excitation voltage 

+

 

2 SEN+ 

Sensing 

input 

+

 

3 SEN- Sensing 

input 

-

 

EXC- 

Load cell excitation voltage 

-

 

SIG+ 

Load cell signal input 

+

 

SIG- 

Load cell signal input 

-

 

7 SHLD 

Frame 

ground 

 

 

 

 

 

 

 

 

 

For 4-wire connection, short-circuit the terminals No.1 and No.2, and terminals No.3 and No.4.

 

 

6. 

CALIBRATION 

Calibrates the AD-4401A to convert the signal from the load cell to a mass value correctly.

 

 

6.1. 

Calibration Setting 

Set the following calibration functions which are required for calibration using calibration weights.

 

CALF- Item 

Setting Value 

Default CALF-

Item 

Setting Value 

Default 

01 Unit 

0: None 
1: g 
2: kg 
3: t 
4: lb 

2 03 Minimum 

division 

1

2

5

10

20

50 d 

02 Decimal 

point 
position

0

 0 

(No D.P.)

1

 0.0 

2

 0.00 

3

 0.000 

4

0.0000 

0 04 Maximum 

capacity 

0 to 999999 

20000 

The rest skipped (For details, refer to the instruction manual) 

 

Press the CAL key in the normal mode.

 

 

When 

Cal

" is displayed, press the ENTER key.

 

 

When “

Cal 5et

” is displayed, press the NET/GROSS key. 

 

 

When “

Cal fnc

” is displayed, press the ENTER key.

 

 

Calibration function mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Panel thickness

1.6 to 3.2 

138

+1

-0

68

 

+1

 

-0 

 

 

 

 

 

 

 

B1 
A1 

B8
A8

3

5 6 

8
 
9

Shield

Sensing 

+

Load cell excitation voltage 

+

Load cell signal 

+

Load cell excitation voltage 

-

Sensing 

-

Load cell signal 

-

 

6-wire connection

 

AD-4401A

 

Control 
panel 

Accessory

packing

 

 

 

Slide rails

Save 

 

Cancel

Live

 

Neutral

680 

12 V

3.3 k

A1

 
 
 
 
 

A6

A7

AD-4401A 

Internal 

Circuit

 

3.3 k

B1

 
 
 
 
 

B8

 
 

A8

Internal 

Circuit

 

AD-4401A 

 


 
 

 

 


 