5.
Drop in the new filters. While installing, be careful that the filters do not
contact the housing or any other objects which might damage or
puncture the filter surface.
6.
Ensure that the flange of the filter is seated fully around the opening.
7.
Close the hold down mechanism and turn the knob 90 degrees to lock
the mechanism in place.
8.
Release the pull handles on the sides of the unit.
9.
Close the lid carefully and secure the latches.
9.3
Fan Installation
For some units, a fan is supplied with the FabriPulse BinVent. If this is the
case, the fan must be installed in accordance with the drawings provided with your
order.
Mount the fan as shown on the drawing on the fan platform. Connect the fan
to the flexible inlet boot, and clamp the boot to the fan and collector using the
provided hose clamps.
9.4
Electrical Connections
WARNING: Potential shock hazard. Disconnect power before servicing. Only
qualified electrical personnel should work on this system.
The FabriPulse BinVent comes fully assembled with a pulse controller in a
NEMA4X enclosure mounted to the unit. Different NEMA ratings are available as an
option. Do not install in classified hazardous locations without an enclosure
suitably rated for the application and location.
The pulse control supplied with the FabriPulse BinVent is the Goyen IS-
DC12X Sequencer. This sequencer only operates in continuous pulsing mode.
To power the sequencer, connect power line to L1 and L2 as shown in the
wiring diagram below. Connection from the sequencer to the solenoid valves is
factory installed with the unit. The pulse controller can be powered with 120/240
VAC connection.