Page 1: ...Power Management Kit A E C V P M S 2 0 0 AEC VPMS 200 Power Management Kit for BOXER Series DC 12V Input and Output AEC VPMS 200 Manual 2nd Ed June 2008 ...

Page 2: ...d in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties that may result from its use The material in this document is for product information only and is subject to change without notice While reasonable efforts have been made in the preparation of this document to ass...

Page 3: ...rd Software International Inc CompactFlash is a trademark of the Compact Flash Association Microsoft Windows is a registered trademark of Microsoft Corp ITE is a trademark of Integrated Technology Express Inc PC AT PS 2 and VGA are trademarks of International Business Machines Corporation All other product names or trademarks are properties of their respective owners ...

Page 4: ...ease make sure that the following materials have been shipped 1 AEC VPMS 200 1 Power Cord to Controller 1 Power Cord to Battery 1 Power Cord to ACC 1 CD ROM for manual in PDF format If any of these items should be missing or damaged please contact your distributor or sales representative immediately ...

Page 5: ...the output 4 If the POWER MANAGEMENT UNIT has fume please disconnect the connectors to the charger and battery immediately and contact with AAEON responsible sales to solve the problem 5 The unit is intended to install in a temperature controlled indoor area free of conductive contaminants 6 A battery can present a risk of electric shock and high short circuit current The following precaution shou...

Page 6: ...NIT will be turned on automatically 3 The POWER MANAGEMENT UNIT begins to output voltage and LED indicators will be illuminated in green 10 seconds later Note the delay time of output voltage is adjustable and the default is 10 seconds 4 If the green LED of the POWER MANAGEMENT UNIT does not illuminated in 10 seconds it means that the POWER MANAGEMENT UNIT works abnormally Please refer to the bull...

Page 7: ...Green LED illuminated steady and it means the POWER MANAGEMENT UNIT operates normally If the green LED flashes it shows the POWER MANAGEMENT UNIT is in battery supply mode 3 If the loading exceeds 133 of nominal value for 3 seconds the overload protection will be activated to stop output ...

Page 8: ...g it or letting it fall could cause damage 7 The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS 8 Make sure the voltage of the power source is correct before connecting the equipment to the power outlet 9 Position the power cord so that people cannot step on it Do not place anything over the power cord 10 All cautions and warnings ...

Page 9: ...vious signs of breakage 15 DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW 20 C 4 F OR ABOVE 60 C 140 F IT MAY DAMAGE THE EQUIPMENT FCC This device complies with Part 15 FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference th...

Page 10: ...AEON Boxer Industrial System 有毒有害物质或元素 部件名称 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr VI 多溴联苯 PBB 多溴二苯醚 PBDE 印刷电路板 及其电子组件 外部信号 连接器及线材 外壳 中央处理器 与内存 硬盘 电源 O 表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ T 11363 2006 标准规定的限量要求以下 X 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T 11363 2006 标准规定的限量要求 备注 一 此产品所标示之环保使用期限 系指在一般正常使用状况下 二 上述部件物质中央处理器 内存 硬盘 电源为选购品 ...

Page 11: ... P M S 2 0 0 x Contents Chapter 1 General Information 1 1 Introduction 1 2 1 2 Features 1 4 1 3 Specifications 1 5 Chapter 2 Quick Installation Guide 2 1 Dimension 2 2 2 2 System Connection Diagram 2 3 2 3 Delay Timer Setting 2 4 ...

Page 12: ...Power Management Kit A E C V P M S 2 0 0 Chapter 1 General Information 1 1 General Chapter 1 Information ...

Page 13: ...r boat and electric cart etc applications such as mobile DVR It will prevent system damage from power surges and eliminate battery drain AEC VPMS 200 provides the following features Input Range 12V DC 12V DC outputs for 72W 12V 8A Input 12V DC Low Battery Protection Battery Voltage under 83 DC 10V of output Delay On Off Time setting 1sec 30 mins Adjustable by on board jumper ...

Page 14: ...ltage DC 12V Mechanical and Environmental Construction Aluminum Alloy Chassis Color Black Mounting Wallmount Default Dimension 5 24 W x 4 07 L x 1 38 H 133mm x 103 4mm x 34mm Net weight 0 374 lb 170g Gross weight 1 1 lb 500g Operating Temperature 5 140 15 60 Operating Humidity 5 90 40 non condensing EMC CE FCC Class A ...

Page 15: ...Power Management Kit A E C V P M S 2 0 0 Chapter 1 General Information 1 4 1 4 I O Front ATX 12V SYS L B Back BAT ACC Timer ...

Page 16: ...Power Management Kit A E C V P M S 2 0 0 Chapter 2 Quick Installation Guide 2 1 Quick Installation Chapter 2 Guide ...

Page 17: ...Power Management Kit A E C V P M S 2 0 0 Chapter 2 Quick Installation Guide 2 2 2 1 Dimension ...

Page 18: ...Power Management Kit A E C V P M S 2 0 0 Chapter 2 Quick Installation Guide 2 3 2 2 System Connection Diagram Battery in ACC in DC output ...

Page 19: ...Power Management Kit A E C V P M S 2 0 0 Chapter 2 Quick Installation Guide 2 4 2 3 Delay Timer Setting Never Never 5 mins 5 min 10 mins 10 min ...

Page 20: ...Power Management Kit A E C V P M S 2 0 0 Chapter 2 Quick Installation Guide 2 5 20 mins 20 min 30 mins 30 min ...

Reviews: