Document number
205065
Version
Rev. N
Issue date
2019-02-04
Sirius OBC and TCM User Manual
Page
169
of
174
Time
On-board reference time
On TCM-S, the time field
consist of CUC Time
Seconds (32-bit), followed by
CUC Time Fractions (16-bit)
Spare
Not used by TCM-S
10.7.10. Source Data
The packet source data of the Telemetry Packets send to ground.
10.7.11. Spare
Spare might be used to pad a packet to an integral number of word if needed.
10.7.12. Packet Error Control
Packet Error Control is used by TCM-S and the checksum of the Packet Error Control Field
shall be calculated using CRC with polynomial 0x8408, LSB first, and initial value 0xFFFF
over the whole TM Packet except the two last octets.
10.8. FARM-parameters
COP-1 is supported on the TCM-S.
10.8.1. FARM_Sliding_Window_Width(W)
In the TCM-S, the parameter W is fixed to 128.
10.8.2. FARM_Positive_Window_Width(PW)
In the TCM-S, the parameter PW is fixed to 64.
10.8.3. FARM_Negative_Window_Width(NW)
In the TCM-S, the parameter NW is fixed to 64.