Page 1: ...PURE SINE WAVE INVERTER User Manual 300W 5000W Multi function LCD display ...
Page 2: ...ce whichever is the real thing 1 Preface 2 Matters needing attention 3 Product features 4 Product application 5 Panel description 6 LCD Display 7 Protection function 7 Product parameters 8 Installation requirements 9 Wiring requirements 10 Common problems and solutions 01 01 02 02 03 05 06 06 07 08 09 09 10 ...
Page 3: ...ne wave inverter All products of our company have undergone strict production control quality control and accurate testing and proof so that all the requirements specified in the specifications can be met after delivery Users can rest assured to buy and use FEATURES APPLICATIONS The inverter power supply adopts SPWM technology controlled by MCU micro processing pure sine wave output and the wavefo...
Page 4: ...FAN ON OFF POWER 300W PANEL DESCRIPTION PANEL DESCRIPTION POWER 600W 2000W OUTPUT LCD display FAN FAN USB FAULT OUTPUT INVERTER ON OFF 04 PAGE 03 PAGE DC DC DC DC ...
Page 5: ...The voltage is reduced automatically to restore the output and the buzzer sounds 4times alarm is cancelled 6 thermal protection 80 5 when overheat protection buzzer sounds 5times alarm with1Hz gap 7 Overload protection 10S automatic shutdown output for overload protection 5S automatic recovery automatic locking for three consecutive times 8 Short circuit protection Output short circuit protection ...
Page 6: ...an cooling LCD Display LCD Display LCD Display LCD Display 3000W 4000W 5000W CUA 3000 CUA 4000 CUA 5000 12V 24V 48V 60V 72Vdc 12Vdc 10 15 24Vdc 20 30 48Vdc 40 60 60Vdc 50 75 72Vdc 60 90 12V 10 0V 0 3 24V 20 0V 0 3 48V 40 0V 0 3 50V 50 0V 0 3 72V 60 0V 0 3 12V 15 0V 0 3 24V 30 0V 0 3 48V 60 0V 0 3 60V 75 0V 0 3 72V 90 0V 0 3 12V 13 2V 0 3 24V 25 5V 0 3 48V 51 0V 0 3 60V 65 0V 0 3 72V 78 0V 0 3 0 80...
Page 7: ... load is turned off to restart 2 The input voltage is too low Make sure the input voltage is within the nominal voltage range Low voltage alarm 1 The battery is out of power and needs to be charged 2 The battery voltage is too low or the contact is poor recharge check the battery terminals or clean the terminals with a dry cloth Inverter has no output 1 The battery voltage is too low recharge or r...
Page 8: ...GE All the data are for reference only please refer to actual data of country Area Plug style Meal case good to assemble the follwing output sockets Universal America German Australia UK France Italy Brazil ...