background image

* Register your product at 

 

a2zozone.com/pages/warranty

SP-3G (220V) Ozone Generator

Operating Manual

Produced for and Distributed by:

A2Z Ozone, Inc

1844 Cargo Court.

Louisville, KY 40299 USA

1+502-499-4977

EPA Est.: 95432-KY-1

Active Ingredient: Ozone.

Warning: Do Not Inhale Ozone. 

Keep Out of Reach of Children.

Produced by:

Bluegrass Water Technology Shenzhen Co., Ltd.

Shenzhen, Guangdong 518110

EPA Est.: 95432-CHN-1

Made in China

Version 1.2.2

Summary of Contents for SP-3G

Page 1: ... Distributed by A2Z Ozone Inc 1844 Cargo Court Louisville KY 40299 USA 1 502 499 4977 EPA Est 95432 KY 1 Active Ingredient Ozone Warning Do Not Inhale Ozone Keep Out of Reach of Children Produced by Bluegrass Water Technology Shenzhen Co Ltd Shenzhen Guangdong 518110 EPA Est 95432 CHN 1 Made in China Version 1 2 2 ...

Page 2: ...stalled must be well ventilated in case of accidental leakage This unit does not contain ozone This unit produces ozone while running by creating oxygen in the air or an oxygen source to ozone Use a degasifier and ozone destructor with the ozone generator HIGH VOLTAGE Perform service on ozone generator by certified technicians only If you suspect a problem disconnect the power to the SP 3G 220V Oz...

Page 3: ...under a cover for protection from the elements Install check valves to prevent backflow into the electrical equipment The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors Keep ambient temperature around the equipment between 40 and 100 Fahrenheit 4 5 to 38 Celsius If installing the equipment in an environment with t...

Page 4: ... SP 3G 220V Ozone Generator SP 3G 220V operating manual 8 Feet Polyurethane Flexible tubing for oxygen supply 8 Feet PTFE tubing for ozone Spare fuse Check valve x2 Spare fan filter Note The SP 3G 220V Ozone Generator is not built with an internal pump This unit requires a pump or oxygen generator to force the ozone out Model Ozone Output g h Electric Power Watts Size Inches Weight lbs SP 3G 3 220...

Page 5: ...o the unit If the power is supplied the LED will illuminate 3 Power Switch Used to power the unit on and off 4 Ozone Concentration Knob Controls the percentage of ozone produced by the unit 5 AMP Meter Shows real time AMP usage 6 Flow Meter Shows the suction amount created by the venturi injector measured in LPM ...

Page 6: ...5 1 2 3 4 5 6 ...

Page 7: ...se If the unit has no power check here first 3 Air Oxygen In Port This sucks in air for the unit to produce ozone Please do not block this intake port Optional oxygen intake or air pump connection 4 Power Cord Supplies power to the unit 1 2 3 4 ...

Page 8: ...e venturi vacuum or system gravity will cause backflow to travel down the ozone output tube and enter into the ozone generator Situate the SP 3G 220V Ozone Generator in a manner suitable for convenient electrical access For convenient wall mounting mounting holes are located on the back of the ozone generator Mounting hardware is not provided The basic installation method for the SP 3G 220V Ozone ...

Page 9: ...es after ozone out fitting Next connect both ends of the cut tubes to the check valve Please direct the arrow on the check valve toward the NOTE The venturi injector has an internal check valve to help prevent backflow Make sure there is a vacuum or that there is suction at the opening via a gauge or test it by putting your finger on the opening There will be a small suction at this opening The su...

Page 10: ... NOTE In a clean environment perform the cleaning procedure every three months Turn the SP 3G 220V Ozone Generator off Clean the filter screen with soap and water Rinse Dry the filter with a clean towel Install the screen back onto the unit Turn the ozone generator on NOTE Be sure the SP 3G 220V Ozone Generator s screen does not touch fan blade CAUTION Thereisextremelyhighvoltageinsidetheozonegene...

Page 11: ... backing up into the ozone generator Inspect the PTFE ozone delivery line daily to ensure water is not flowing back into the ozone generator Replace check valves every 6 months to a year of use NOTE The only time it is possible for water to flow back toward the ozone generator is during a system shutdown Always inspect tube and check valve during this time Fuses The fuse is located on the panel at...

Page 12: ...to 2 hours to dry the ozone tube Check the main fuse Change it if needed It is a 3 AMP for this unit Check the tubing inside the machine for kinks If the machine can produce some air but the air is not ozone please check the following The power indication lamp is lit Check the ozone control knob is set above zero Check the ozone board fuse Check the wire from terminal to ozone board Check that the...

Page 13: ...d ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND SUCH WARRANTIES ARE HEREBY DISCLAIMED AND e A2Z Ozone SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR LOSS OF USE OF SUCH PRODUCTS LOST PROFITS DIRECT DAMAGES INDIRECT DAMAGES CONSEQUEN TIAL DAMAGES AND OR INCIDENTAL DAMAGES TO OBTAIN WARRANTY SERVICE Contact A2Z Ozone 1844 Cargo Court Louisville KY...

Page 14: ...______________State_________Zip__________ Phone ____ ________________ Dealer Info Dealer Name______________________________ Dealer Address_______________________________________________________ City_________________________________State_________Zip__________ Phone ________________ Purchase Product Info Purchased Date _______________________Date Installed____________________ Product Purchased _____...