In the RT10 series servo, the PA menu only displays parameters up to
parameter 99 by default. If it is old version, change the PA0 to 527, it
will display all the parameters.
3.3.3 Parameter management
Parameter management mainly handles the operation between the
parameter table and EEPROM.
In the menu level one select
and press the Enter key to go
to the parameter management mode. Use the Page up or Page down
button to switch between the three parameter management options.
Press and hold the Enter key for more than 3 seconds to complete the
parameter management command. Press the return key to return.
①
Parameter save
Write the parameters in the parameter table to the EEPROM
parameter zone.
When the parameter is modified, it only changes the parameter values
in the parameter table. If the servo is powered off and then powered up,
and the original parameter value will be restored by default again. If you
want to change the parameter value permanently, you need to perform
parameter save operation and write the parameters in the parameter table
to the EEPROM.
②
Reset to factory defaults
The factory values of all parameters are read to the parameter table
and written to the EEPROM parameter area. After power cycle, the factory
default values of all parameters are applied.
When the parameter configuration is disordered, you can use this
operation to recover the system.
③
System soft reset