A-TS
38
https://a-ts.cn/en/
P1.08 Mutual inductance
Range: 0.0
~
2000.0
%【
depending on model
】
After the success of the motor parameter self learning, P1.04 ~ P1.08
parameters will be automatically updated.
After change P1.02 motor rated power, P1.04 ~ P1.08 parameter value
will be back to the factory.
P1.09 Rated slip frequency
Range: 0.00
~
20.00Hz
【
0Hz
】
The motor rated speed can be obtained by the motor nameplate.
P1.10 Auto tuning
Range: 0
~
2
【
0
】
0: Auto-tuning is disabled
1: Stationary auto-tuning ( Start auto-tuning to a standstill motor
Before starting auto-tuning, values on the motor nameplate must be input
correctly ( P1.01~P1.03 ) . When starting auto-tuning to a standstill
motor, the stator resistance, rotor resistance and the leakage inductance
will be measured and the measured values will be written into P1.05,
P1.06 and P1.07 automatically.
2: Rotating auto-tuning
When starting a rotating auto-tuning, at first, the motor is in standstill
status, and the stator resistance , rotor resistance and the leakage
inductance will be measured, and then the motor begins to rotate, mutual
inductance, parameters will be measured and written into P1.05, P1.06,
P1.07, P1.08 and P1.04 automatically.
After auto-tuning, P1.10 will be set to 0 automatically.
Auto-tuning procedures:
1 )
Set the “P0.06 basic operating frequency” and “P0.07 Max output
voltage” correctly according to the motor feature;
2 ) Set the P1.01, P1.02 and P1.03 correctly;