Analog
output
AO
Analog output
Be able to
output analog
voltage/current,
Jumper CN6
can select
voltage or
current input
mode. Voltage
input mode is
the default
mode. Refer to
P6.04 for details
( reference
ground: GND )
Output current
range:
0/4~20mA
Output voltage
range: 0/2~10V
Digital input
X1
~
X5
Multi-functional
digital inputs 1
~
5
Can be defined
as
multi-functional
digital inputs,
see Section 7.6
Reference
ground: COM
Optical-isolator
2-way input
input
resistance: 2k
Ω
maximum input
frequency:
200Hz
Input voltage
range: 9~30V
PLC
Common terminal
Common
terminal for
multi-functional
inputs
P24
+24V supply
Pro24V
power supply
Output:
+24V,set point
accuracy: ±10%
Max output
current: 200mA
COM
+24V common
terminal
Isolated
internally with
GND
Isolated
internally with
GND
Digital input
Y1
Open collector
output 1
Programmable
terminals,
defined as
multi-function
digital outputs,
see Section 7.7.
Optical-isolator
output:
24VDC/50mA