9
rough-In-dimensions
Units
A
B
C
D
E
F
Inches
66.75
49.25
22.00
15.75
3.00
8.00
cm
169.5 125.09 55.88
40.00
7.62
20.32
top/side Inlet and outlet: 3/4” npt
Gas Inlet: 1/2” npt
capacity, Gas and electrical characteristics
Approximate Capacity
Manifold Pressure
Electrical Characteristics
U.S. Gals.
Liters Gas Type
“WC
kPA
Volts/Hz
Amperes
50
189
Nat./LP
0”
0”
120/60
<5
Maximum supply pressure: 14 inches w.c. (3.48kpa)
Minimum supply pressure for natural Gas: 3.50” (.87kpa)
Minimum supply pressure for propane Gas: 8.00” (1.99kpa)
Minimum pressure must be maintained under both load and no load (dynamic and static) conditions.
recovery capacities - u.s. Gallons/hr. and liters/hr. at temperature rise Indicated
Input
Recovery Capacities
Rating
(Btu/hr)
Rating
(kW)
Temp.
Rise
F
30
40
50
60
70
80
90
100
110
120
130
140
C
17
22
28
33
39
44
50
56
61
67
72
78
100,000
29.3
GPH
387
291
233
194
166
145
129
116
106
97
90
83
LPH
1465
1102
882
734
628
549
488
439
401
367
341
314
Recovery capacity based on 96% thermal efficiency
rouGh In dIMensIons
fIGure 1a.
InstallatIon consIderatIon
Summary of Contents for Vertex 100 Power Vent DV Series 120
Page 5: ...5 general safety information...
Page 56: ...56 notes...
Page 57: ...57 notes...
Page 58: ...58 notes...