Water Heater

HSE-SNJ-015 / HSE-SNJ-025

Size: 210mm (H) x 148mm (W) 
Part No.: 326221-000_R0
Updated on: 12-04-2013

User Guide

Summary of Contents for Jaguar HSE-SNJ-015

Page 1: ...Water Heater HSE SNJ 015 HSE SNJ 025 Size 210mm H x 148mm W Part No 326221 000_R0 Updated on 12 04 2013 User Guide...

Page 2: ...Wall Mounting Accessories Discharge Tube User Guide Specifications 1 Key Features 2 Installation 3 Directions for use 5 Troubleshooting 6 Circuit Diagram 6 Warranty Card 7 Jaquar Company Pvt Ltd 13 W...

Page 3: ...12 PU Insulation 13 Thermal Cutout Part Descriptors 1 Model HSE SNJ 015 HSE SNJ 025 Volume L 15 25 Power W 2000 2000 Voltage Frequency V Hz 230 50 230 50 Actual Stdg Loss kWh 24h 45 C diff 0 592 0 721...

Page 4: ...e water in case the pressure overshoots the preset limits Safety Valve If the water temperature exceeds the highest preset level the breaker rapidly cuts off the live line and the neutral line simulta...

Page 5: ...be 120mm and the vertical distance should be 57mm Fig 2 4 Insert the expansion anchors into the holes Place the wall mounting bracket over the expansion anchors and tighten the screws on the bracket F...

Page 6: ...ube should be installed downwards without any loops folds or knots Ensure that the free end of the Discharge tube is placed over a suitable drain and away from the users Discharge tube is provided to...

Page 7: ...n During repair or periodic maintenance if necessary the power cord or Internal electrical wiring should be replaced by authorised service personnel only It is not permitted for the power supply plug...

Page 8: ...ror Green light on Non functioning Call Customer Care Centre Red light off thermostat No hot water Control circuit or internal wiring error Water temperature Thermostat set is too high Call Customer C...

Page 9: ...quar is to provide consumers more value for their money The reason why Jaquar believes in that Its products must make Friends not just Customers To further its commitment to customer delight Jaquar of...

Page 10: ...l expenses incurred This warranty is not valid for damage resulting from faulty installation mishandling negligence accidents and unauthorised repairs We hereby warrant this product against failure ar...

Page 11: ...quar is to provide consumers more value for their money The reason why Jaquar believes in that Its products must make Friends not just Customers To further its commitment to customer delight Jaquar of...

Page 12: ...l expenses incurred This warranty is not valid for damage resulting from faulty installation mishandling negligence accidents and unauthorised repairs We hereby warrant this product against failure ar...

Page 13: ...ability and Service The key philosophy of Jaquar is to provide consumers more value for their money The reason why Jaquar believes in that Its products must make Friends not just Customers To further...

Page 14: ...l expenses incurred This warranty is not valid for damage resulting from faulty installation mishandling negligence accidents and unauthorised repairs We hereby warrant this product against failure ar...

Page 15: ...Corporate Office 306 Udyog Vihar Phase 2 Gurgaon Haryana Tel 0124 474 6800 20 Customer Care Toll Free 1 800 121 6808 13 Jaquar and Company Pvt Ltd...

Page 16: ...Water Heating Private Limited Plot No 300 Phase 2 KIADB Industrial Area Harohalli Kanakapura Taluk Ramanagara District 562 112 Karnataka India Toll Free 1 800 103 2468 Website www aosmithindia com Par...

Reviews: