8.7
Venting system
There are several alternatives for installation of the air inlet and flue gas outlet:
Installation
type
Version
Description
B23
Open
Air for combustion is drawn from installation room
and the flue gasses leave the water heater via a
vertical roof terminal.
C13
Closed
Concentric and/or parallel venting system, with
horizontal air inlet and flue gas outlet, in same
pressure zone.
C33
Closed
Concentric and/or parallel venting system, with
vertical air inlet and flue gas outlet, in same
pressure zone.
C43
Closed
Water heaters on common air inlet and flue gas
outlet (concentric and/or parallel) in a multiple
floor building.
C53
Closed
Separate air inlet and flue gas outlet terminal
types mixed. Air inlet and flue gas outlet
termination may be in different pressure zone.
C63
Closed
Water heaters supplied without venting materials.
These water heaters must be installed in
compliance with local regulations. The water heater
is intended to be connected to a separately
approved and marketed venting system.
This manual does not discus installation type B23. When you need a B23 system, contact
A.O. Smith for more information.
Caution
Always make sure that the flue gas outlet discharges into an area approved for the
correct type of installation.
Caution
The use of a different wall or roof terminal can result in incorrect functioning of the water
heater. Use the part number from the table to order a terminal set from your supplier or
the manufacturer.
c
42
Installation, Maintenance and Service part
Summary of Contents for Innovo 12-160
Page 6: ...6...
Page 13: ...User part 0312266_INNOVO_UKUK_V3 0 2017 02 10 13...
Page 14: ...14...
Page 16: ...16 User part...
Page 18: ...18 User part...
Page 24: ...24 User part...
Page 27: ...Installation Maintenance and Service part 0312266_INNOVO_UKUK_V3 0 2017 02 10 27...
Page 28: ...28 User part...
Page 36: ...36 Installation Maintenance and Service part...
Page 43: ...Fig Venting systems 0312266_INNOVO_UKUK_V3 0 2017 02 10 43...
Page 58: ...58 Installation Maintenance and Service part...
Page 70: ...70 Installation Maintenance and Service part...
Page 83: ...0312266_INNOVO_UKUK_V3 0 2017 02 10 83...
Page 87: ...13 5 Declaration of conformity 0312266_INNOVO_UKUK_V3 0 2017 02 10 87...