8.2.3
Water composition
The water must comply with the regulations for drinking water for human consumption.
Water composition
Hardness
(alkaline earth ions)
> 1.00 mmol/l:
German hardness > 5.6° dH
French hardness > 10.0° fH
English hardness > 7.0° eH
CaCO
3
> 100 mg/l
•
•
•
•
Conductivity
> 125 µS/cm
Acidity (pH value)
7.0 < pH value < 9.5
Note
If the water specifications differ from the specifications in the table, the tank protection
cannot be guaranteed, refer to Warranty.
8.2.4
Working clearances
Make sure that there is sufficient clearance to access the water heater:
100 cm in front of the water heater (AA).
50 cm at the left and right side of the water heater (BB).
100 cm at the top of the water heater.
Fig. Working clearances
8.2.5
Level the water heater
Make sure that the water heater is level, before installation:
Use a wrench to turn the nut (1) on the adjustable leg clockwise to move the water
heater up.
Use a wrench to turn the nut (1) on the adjustable leg anticlockwise to move the
water heater down.
The water heater can move up maximal 20 mm.
Note
Make sure that the working clearance at the top of the water heater does not become
smaller than 100 cm.
n
•
•
•
•
•
n
38
Installation, Maintenance and Service part
Summary of Contents for Innovo 12-160
Page 6: ...6...
Page 13: ...User part 0312266_INNOVO_UKUK_V3 0 2017 02 10 13...
Page 14: ...14...
Page 16: ...16 User part...
Page 18: ...18 User part...
Page 24: ...24 User part...
Page 27: ...Installation Maintenance and Service part 0312266_INNOVO_UKUK_V3 0 2017 02 10 27...
Page 28: ...28 User part...
Page 36: ...36 Installation Maintenance and Service part...
Page 43: ...Fig Venting systems 0312266_INNOVO_UKUK_V3 0 2017 02 10 43...
Page 58: ...58 Installation Maintenance and Service part...
Page 70: ...70 Installation Maintenance and Service part...
Page 83: ...0312266_INNOVO_UKUK_V3 0 2017 02 10 83...
Page 87: ...13 5 Declaration of conformity 0312266_INNOVO_UKUK_V3 0 2017 02 10 87...