THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY.  If the
glass lined tank in this water heater shall prove upon examination by A. O.
Smith Corporation (the warrantor) to have leaked during the warranty
period in normal residential use, due to natural corrosion from potable
water therein, the warrantor will furnish the ORIGINAL OWNER a
replacement A. O. Smith water heater of equivalent size and current
model, or a replacement part for any thermostat or thermocouple which
fails in normal use, in accordance with the warranty terms and conditions
specified below.  THE A. O. SMITH REPLACEMENT MODEL OR PART WILL
BE WARRANTED FOR ONLY THE UNEXPIRED PORTION OF THE ORIGINAL
WARRANTY.  The warranty period will be determined by the original
installation date of the water heater.  PROOF-OF-PURCHASE AND PROOF-
OF-INSTALLATION ARE NECESSARY TO VALIDATE THIS WARRANTY.
This warranty is not transferable and applies to models listed in Table 1.

TABLE 1

WARRANTY PERIOD

MODEL

TANK

1

PARTS

2

GPSX

6 YEARS

6 YEARS

When the water heater has been used for other than single family
residential application: 1.  The  tank warranty shall be reduced  to 1 year.
2. The parts warranty shall be reduced to 1 year for all models.  Returned
parts which meet any of the following conditions are not covered by this
warranty: 1) improper installation or removal; 2) damaged by other than
normal wear; 3) replaced for cosmetic purposes; or 4) returned with
defaced date codes.

CONDITIONS AND EXCEPTIONS

This warranty shall apply only when the water heater is installed and
operated in accordance with: 1) all local fire codes and plumbing codes,
ordinances and regulations; 2) the printed instructions provided with it;
3) good industry practices; and 4) proper safety practices such as but
not limited to a properly sized drain pan if installed in an area where
leakage from connections of the tank would result in damage to the area
adjacent to the heater.  In addition, a new temperature and pressure
relief valve, certified by the American Gas Association must have been
properly installed and piped to the nearest drain.

This warranty shall apply only when the heater is:

owned by the original purchaser;

used at temperatures not exceeding the maximum calibrated
setting of its thermostat;

not subjected to excessive water pressure fluctuations and
not subject to an operating pressure greater than 150 P.S.I.;

filled with potable water, free to circulate at all times and with     the
tank free of damaging water sediment or scale deposits;

used in a non-corrosive and non-contaminated atmosphere;

used with factory approved anode(s) installed;

in its original installation location;

in the United States, its territories or possessions, and

sized in accordance with proper sizing techniques for residential
water heaters;

bearing a rating plate which has not been altered, defaced or
removed except as required by the warrantor;

not used in a closed system without a properly sized and installed
thermal expansion tank;

fired at the factory rated input using the fuel stated in the face of the
rating plate;

operated with the inner and outer combustion chamber doors
in place;

maintained in accordance with the instructions printed in the manual
included with the heater.

Any accident to the water heater or any part thereof (including freezing,
fire, floods, or lightning), any misuse, abuse or alteration of it, any
operation of it in a modified form, or any attempt to repair tank leaks or
parts, will void this warranty.

SERVICE AND LABOR RESPONSIBILITY

UNDER THIS LIMITED WARRANTY, THE WARRANTOR WILL PROVIDE
ONLY A REPLACEMENT WATER HEATER OR PART THEREOF.  THE OWNER
IS RESPONSIBLE FOR ALL OTHER COSTS.  Such costs may include but
are not limited to:
a. Labor charges for service, removal, or reinstallation of the water

heater or part thereof.

LIMITED RESIDENTIAL GAS WARRANTY

b. Shipping and delivery charges for forwarding the new water heater

or replacement part from the nearest distributor and returning the
claimed defective heater or part to such distributor except in the
state of California where such charges are the manufacturer’s
responsibility.

c. All cost necessary or incidental for handling and administrative

charges, and for any materials and/or permits required for installation
of the replacement heater or part.

LIMITATION ON IMPLIED WARRANTIES

Implied warranties, including any warranty of merchantability imposed
on the sale of this heater under state law are limited to one year duration
for the heater or any of its parts.  Some states do not allow limitations on
how long an implied warranty lasts, so the above limitations may not
apply to you.

CLAIM PROCEDURE

Any claim under this warranty should be initiated with the dealer who
sold the heater, or with any other dealer handling the warrantor’s products.
If this is not practical, the owner should contact: A. O. Smith Water
Products Company,  5621 West 115th Street, Alsip, Illinois, 60803 (800)
323-2636.

The warrantor will only honor replacement with identical or similar water
heater or parts thereof which are manufactured or distributed by the
warrantor.

Dealer replacements are made subject to in-warranty validation by
warrantor.

PROOF-OF-PURCHASE AND PROOF-OF-INSTALLATION DATES ARE
REQUIRED TO SUPPORT WARRANTY FOR CLAIM FROM ORIGINAL
OWNER.  THIS FORM DOES NOT CONSTITUTE PROOF-OF-PURCHASE
OR PROOF-OF-INSTALLATION.

DISCLAIMERS

NO EXPRESSED WARRANTY HAS BEEN OR WILL BE MADE IN BEHALF
OF THE WARRANTOR WITH RESPECT TO THE MERCHANTABILITY OF
THE HEATER OR THE INSTALLATION, OPERATION, REPAIR OR
REPLACEMENT OF THE HEATER OR PARTS.  THE WARRANTOR SHALL
NOT BE RESPONSIBLE FOR WATER DAMAGE, LOSS OF USE OF THE
UNIT, INCONVENIENCE, LOSS OR DAMAGE TO PERSONAL PROPERTY,
OR OTHER CONSEQUENTIAL DAMAGE.  THE WARRANTOR SHALL NOT
BE LIABLE BY VIRTUE OF THIS WARRANTY OR OTHERWISE FOR
DAMAGE TO ANY PERSONS OR PROPERTY, WHETHER DIRECT OR
INDIRECT, AND WHETHER ARISING IN CONTRACT OR IN TORT.

Some states do not allow the limitation or exclusion of incidental or
consequential damages, so the above limitation or exclusion may not
apply to you.

This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state. Should governmental regulations or
industry standards prohibit the Manufacturer from furnishing a comparable
model replacement under this warranty, the Owner will be furnished with
the closest comparable water heater meeting the current governmental
regulations and industry standards. A supplementary fee may be assessed
to cover the additional cost associated with the changes made to meet
applicable regulations and standards.

Fill out and keep with water heater.

IMPORTANT INFORMATION

   Model Number____________________________________________

   Serial Number_____________________________________________

  Installation Information:

   Date Installed _____________________________________________

   Company’s Name _________________________________________

   Street or P.O. Box _________________________________________

   City, State, and Zip Code  ___________________________________

   Phone Number _______________Plumber’s Name_______________

Summary of Contents for GPSX-50L

Page 1: ...installation and or operation of this water heater Please pay particular attention to the important safety and operating instructions as well as the WARNINGS and CAUTIONS CAUTION TEXT PRINTED OR OUTL...

Page 2: ...45 When ordering parts provide complete model and serial numbers see rating plate quantity and name of part desired as listed in Figure 1 Standard hardware items may be purchased locally FIGURE1 N COL...

Page 3: ...ep it on the side of the water heater or nearby for future reference Do obtain new warning and instruction labels for placement on the blanket directly over the existing labels Do inspect the insulati...

Page 4: ...g jurisdiction In the absence of local codes the installation must comply with the current editions of the National Fuel Gas Code ANSI Z223 1 NFPA 54 and the National Electrical Code NFPA 70 The forme...

Page 5: ...be suitable for use with potable water 2 Toxic chemicals such as those used for boiler treatment shall NEVER be introduced into this system 3 This unit may NEVER be connected to any existing heating...

Page 6: ...3 1 NFPA54 7 3 4e and 7 8a b as follows 1 The exit terminals of a mechanical vent system shall be not less than 7 feet above grade when located adjacent to public walkways Figure 3 2 A venting system...

Page 7: ...erminal to mount on the pipe Before the vent terminal is installed caulk not supplied around the pipe on the exterior wall and install the wall plate can be held to the outside wall by placing some of...

Page 8: ...SERVICING THIS UNITIS MANUFACTURED WITHAN EXTERNALCONTROL HARNESS FOR EASIER REPLACEMENT IF THE HARNESS OR CONNECTORS GET DAMAGED Do not plug in power cord until vent system is completely installed Th...

Page 9: ...ngs 4 The vent piping should be connected to the blower with a rubber adapter and secured with hose clamps The adapter and clamps are provided with the heater 5 Even though the flue gas temperature le...

Page 10: ...ar the majority of failures in PVC and CPVC systems are the result of shortcuts and or improper joining techniques 2 SELECTIONOFMATERIALS Cutting Device Saw or Pipe Cutter Deburring Tool Knife File or...

Page 11: ...fitting sockets and remove all dirt grease or moisture with a clean dry rag If wiping fails to clean the surfaces a chemical cleaner must be used Check for possible damage such as splits or cracks and...

Page 12: ...ot water line Make sure that the insulation is against the top cover of the heater Fit T P valve insulation over valve Make sure that the insulation does not interfere with the lever of the T P valve...

Page 13: ...LER and HOTTER buttons together and holding for 1 second Then press the COOLER button until the WARM indicator light appears 2 Set the ON OFF switch on the blower control box to the OFF position 3 Tur...

Page 14: ...you experience this type of use you should consider using lower temperature settings to reduce scald hazards Valves for reducing the point of use temperature by mixing cold and hot water are available...

Page 15: ...Y INFORMATION SECTION FIRST USERS OF THIS APPLIANCE SHOULD BE AWARE THAT GAS COMPONENTS WEAR OUT OVER A PERIOD OF TIME THE GAS CARRYING COMPONENTS OFTHISAPPLIANCE SHOULD BE INSPECTED FOR PROPER OPERAT...

Page 16: ...will damage the heater Turn off the gas and cold water inlet valve to the heater Open a nearby hot water faucet and the heater drain valve BE CAREFUL TO GRASP THE DRAIN VALVE HANDLE SO THAT THE HAND...

Page 17: ...correct and secure 2 Replace hot surface ignitor System in lockout 1 Gas supply is off or too low to operate 2 Hot surface ignitor not positioned correctly 3 Low voltage to the water heater 4 Electric...

Page 18: ...g and YELLOWFLAME air openings in bottom base pan for obstructions or blockage C Not enough dilution air for proper Check dilution air intake for obstructions combustion or blockage A Water on the flo...

Page 19: ...empt to repair tank leaks or parts will void this warranty SERVICEANDLABORRESPONSIBILITY UNDERTHISLIMITEDWARRANTY THEWARRANTORWILLPROVIDE ONLYAREPLACEMENTWATERHEATERORPARTTHEREOF THEOWNER ISRESPONSIBL...

Page 20: ...20 5621 W 115TH STREET ALSIP IL 60803 PHONE 1 800 433 2545 FAX 1 800 433 2515 www hotwater com E mail parts hotwater com REPLACEMENT PARTS...