Now set the day and time the same way as described for setting an extra period in
the week menu (see section 4.3.9). In this case however, the pump will be
automatically started.
Select START to start.
9.2.8
Solar heating system configuration
Use the solar heating system settings menu to reach the menus shown here:
9.2.8.1
Setting the drain-back tank
Use this menu to specify whether the solar heating system is equipped with a drain-back
tank for the heating fluid. Call up the menu as follows:
[
]:SETTINGS SOLAR | DRAIN BACK.
The default is NO.
Note
During commissioning, it is important to check whether this setting corresponds with the
configuration of the solar heating system.
9.2.8.2
Switching on the solar pump
This menu lets you switch on the pump in the solar heating system manually. Call up this
menu as follows:
[
]: SETTINGS SOLAR | TEST SOLAR PUMP.
The following display appears.
When START is selected, the pump will start to run for two minutes. Once the 2 minutes
have elapsed, the pump stops running again.
9.2.8.3
Setting the solar limit
The solar limit temperature is the maximum water temperature obtained in the appliance
via the solar heating system (measured by sensor T
1
).
This value can be set between 65 and 80 °C. The default value is 65 °C.
If you set the solar limit higher than the set point (see section 4.3.3), then the solar pump
will be started in order to heat the water further once the set point has been reached.
However, this only makes sense if the solar heating system is actually generating heat.
This makes use of the difference between the temperature at the top of the solar collector
(S
1
) and that in the appliance (measured by S
2
).
Call up the menu for the solar limit as follows:
[
]: SETTINGS SOLAR | SOLAR LIMIT.
•
•
•
n
•
•
0311753_SGS_28-120_II_UKUK_V2.0 , 2017-05-03
87
Summary of Contents for BFC-120
Page 6: ...6...
Page 13: ...User part 0311753_SGS_28 120_II_UKUK_V2 0 2017 05 03 13...
Page 14: ...14...
Page 16: ...16 User part...
Page 18: ...18 User part...
Page 24: ...24 User part...
Page 40: ...40 User part...
Page 41: ...Installation Maintenance and Service part 0311753_SGS_28 120_II_UKUK_V2 0 2017 05 03 41...
Page 42: ...42 User part...
Page 82: ...82 Installation Maintenance and Service part...
Page 90: ...90 Installation Maintenance and Service part...
Page 104: ...104 Installation Maintenance and Service part...
Page 110: ...Fig Dimensions SGS 28 30 50 60 110 Installation Maintenance and Service part...
Page 112: ...Fig Dimensions SGS 80 100 120 112 Installation Maintenance and Service part...
Page 121: ...12 8 Declaration of conformity 0311753_SGS_28 120_II_UKUK_V2 0 2017 05 03 121...
Page 124: ...124 Installation Maintenance and Service part...
Page 126: ...126 Installation Maintenance and Service part...