520 Indoor / 520 Outdoor Service Manual
Ver. 1.00
47
CONFIDENTIAL
Error Code
Malfunction description
Cancellation method
341
Disconnected/short-circuited exhaust thermistor
(520 Indoor only)
Turn off the power or water supply
Diagnosis
Checkpoint
1 Exhaust thermistor fault
(Refer to section 10-13)
Visual inspection: connection/breakage of wires and/or debris on
thermistor.
Check voltage/resistance between white & white (#52).
Refer to Section 8 (B) for proper range of values.
K1
Error Code
Malfunction description
Cancellation method
391
Disconnected AFR rod
Turn off the power or water supply
Diagnosis
Checkpoint
1 AFR rod fault
(Refer to section 10-7)
Visual inspection: connection/breakage of wires, soot on it.
I
Error Code
Malfunction description
Cancellation method
441
Flow sensor failure (Easy-Link system only)
Turn off the power or water supply
Diagnosis
Checkpoint
1 Flow sensor failure
(Refer to section 10-10)
Visual inspection: connection/breakage of wires and/or debris on impeller.
Check voltage/resistance between (red & black) or (white & black)
H2