background image

22

Excessive condensation may be noticed during the winter and 
early spring months when incoming water temperatures are at their 
lowest.

Good venting is essential for a gas 

fi

 red water heater to operate 

properly as well as to carry away products of combustion and water 
vapor.

SMOKE / ODOR

It is not uncommon to experience a small amount of smoke and odor 
during the initial start-up.  This is due to burning off of oil from metal 
parts, and will disappear in a short while.

THERMAL EXPANSION

As water is heated, it expands (thermal expansion). In a closed 
system, the volume of water will grow. As the volume of water 
grows, there will be a corresponding increase in water pressure 
due to thermal expansion. Thermal expansion can cause premature 
tank failure (leakage). This type of failure is not covered under the 
limited warranty. Thermal expansion can also cause intermittent 
temperature-pressure relief valve operation: water discharged from 
the valve due to excessive pressure build up. The temperature-
pressure relief valve is not intended for the constant relief of 
thermal expansion. This condition is not covered under the limited 
warranty.

A properly sized thermal expansion tank should be installed on all 
closed systems to control the harmful effects of thermal expansion. 
Contact a local plumbing service agency to have a thermal expansion 
tank installed.

STRANGE SOUNDS

Possible noises due to expansion and contraction of some metal 
parts during periods of heat-up and cool-down do not necessarily 
represent harmful or dangerous conditions.

Condensation causes sizzling and popping within the burner area 
during heating and cooling periods and should be considered normal.  
See “Condensation” in this section.

OPERATIONAL CONDITIONS

SMELLY WATER

In each water heater there is installed at least one anode rod (see 
parts sections) for corrosion protection of the tank.  Certain water 
conditions will cause a reaction between this rod and the water.  
The most common complaint associated with the anode rod is one 
of a “rotten egg smell” in the hot water.  This odor is derived from 
hydrogen sul

fi

 de gas dissolved in the water.  The smell is the result 

of four factors which must all be present for the odor to develop:

a.  A concentration of sulfate in the supply water.

b.  Little or no dissolved oxygen in the water.

c.  A sulfate reducing bacteria which has accumulated within the 

water heater (this harmless bacteria is nontoxic to humans).

d.  An excess of active hydrogen in the tank.  This is caused by the 

corrosion protective action of the anode.

Smelly water may be eliminated or reduced in some water heater 
models by replacing the anode(s) with one of less active material, 
and then chlorinating the water heater tank and all hot water lines.  
Contact the local water heater supplier or service agency for 
further information concerning an Anode Replacement Kit and this 
chlorination treatment.

If the smelly water persists after the anode replacement and 
chlorination treatment, we can only suggest that chlorination or 
aeration of the water supply be considered to eliminate the water 
problem.

Do not remove the anode leaving the tank unprotected.  By doing 
so, all warranty on the water heater tank is voided.

“AIR” IN HOT WATER FAUCETS

HYDROGEN GAS: Hydrogen gas can be produced in a hot water 
system that has not been used for a long period of time (generally 
two weeks or more).  Hydrogen gas is extremely 

fl

 ammable  and 

explosive.  To prevent the possibility of injury under these conditions, 
we recommend the hot water faucet, located farthest away, be 
opened for several minutes before any electrical appliances 
which are connected to the hot water system are used (such as a 
dishwasher or washing machine).  If hydrogen gas is present, there 
will probably be an unusual sound similar to air escaping through the 
pipe as the hot water faucet is opened.  There must be no smoking 
or open 

fl

 ame near the faucet at the time it is open.

HIGH WATER TEMPERATURE SHUT OFF SYSTEM

This water heater is equipped with an automatic gas Shut-off system.  
This system works when high water temperatures are present. 
Turn “OFF” the entire gas supply to the water heater.  The high 
temperature Shut-off is built into the gas control valve/thermostat.  
It is non-resettable.  If the high temperature Shut-off activates, the 
gas control valve/thermostat must be replaced. Contact a quali

fi

 ed 

technician.

Summary of Contents for 315795-000 MH

Page 1: ...TY QUESTIONS SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED IF YOUARE UNSUCCESSFUL PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER RESIDENTIAL DIRECT VENT GAS WATER HEATERS For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER FOR USE ONLY WITH VENTING SYSTEMS SUPPLIED WITH THE WATER HEATER WHETHER A NEW INSTALLATION OR...

Page 2: ...heaters and to work with natural L P gas gas air venting and gas components Its employees and representatives must also have appropriate trade knowledge and a thorough understanding of the requirements of the Natural Gas and Propane Installation Code CSA B149 1 current edition as it relates to the installation of gas fired water heaters The service agency employees representatives must also have a...

Page 3: ...3 GENERAL SAFETY ...

Page 4: ...s fired water heater is design certified by CSAINTERNATIONAL under American National Standard CSA Standard for Gas Water Heaters for Manufactured Home Installation ANSI Z21 10 1 CSA4 1 current edition PREPARING FOR THE INSTALLATION 1 Read the General Safety section page 3 of this manual first and then the entire manual carefully If you don t follow the safety rules the water heater will not operat...

Page 5: ...p Leg Sediment Trap K Manifold Door L Outer Door M Union N Inlet Water Shut off Valve O Cold Water Inlet P Inlet Nipple Q Temperature Pressure Relief Valve R Rating Plate S Flue Baffle T Gas Control Valve Thermostat U Drain Valve V Pilot and Main Burner W Flue X Air Duct Assembly Y Metal Drain Pan Z Thermostat Shield optional ZZ Piezo Igniter ALL PIPING MATERIALS TO BE SUPPLIED BY CUSTOMERS TO VEN...

Page 6: ...t water than others These include the elderly children the infirm or physically mentally handicapped If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water ...

Page 7: ...2 square inches 81 28 square cm Other gas fired appliance in the home will require additional free air openings consult these manufacturers for correct sizing see Figure 3 FIGURE 3 If the manufactured home is installed over a basement or crawlspace combustion air must be supplied from outside the manufactured home The combustion air intake piping can be 3 7 62 cm PVC for 30 Gallon 113 56 Liter and...

Page 8: ...moving vehicle This water heater must not be installed directly on carpeting Carpeting must be protected by metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 inches 76 2 mm in any direction or if the appliance is installed in an alcove or closet the entire floor must be covered by the panel Failure to heed this warning may result in ...

Page 9: ...or thermostat or temperature pressure relief valve Do not allow insulation to come within 2 50 8 mm of the floor to prevent blockage of combustion air flow to the burner Do not cover the instruction manual Keep it on the side of the water heater or nearby for future reference Do obtain new warning and instruction labels from the manufacturer for placement on the blanket directly over the existing ...

Page 10: ...TER TO FLOOR AND WALL The water heater must be secured to the floor and to the wall of the enclosure with the three mounting brackets and screws packaged in the carton with the water heater The two small brackets are used to attach the water heater to the floor and the one large bracket is used to secure the top of the water heater to the wall Because of installation variances these brackets can b...

Page 11: ...ow to telescope more freely 3 Telescope down the outer pipe of the roof jack assembly to a length that will project at least 2 5 08 cm below the finished ceiling before installing the roof jack assembly see Figure 14 FIGURE 14 4 Ease the roof jack assembly through the roof and ceiling openings The roof jack flashing tilts up to 22 6 degrees for use on a sloping roof 5 Use sealant or caulk on the r...

Page 12: ...chedule 40 intake air vent piping Optional Kit no 9002987005 contains a 4 10 16 cm PVC Schedule 40 45 vent cap with screen and two 4 10 16 cm wall collars ALL MODELS 1 PVC ABS or CPVC Schedule 40 piping and fittings are acceptable materials for the intake air vent system 2 The intake air vent system must terminate horizontally to the outdoors 3 Remove the screws which attach the wind baffle to the...

Page 13: ...s Wear impervious clothing while handling Do not smoke eat or drink while handling Wash thoroughly after handling and before eating Wear eye protection when handling If swallowed drink water do not induce vomitting and call a physician or poison control center immediately If inhaled get fresh air and seek medical attention if ill feelings persist In case of eye and skin contact immediately flush w...

Page 14: ...ieving point of the water heater s temperature pressure relief valve is reached the valve will relieve the excess pressure The temperature pressure relief valve is not intended for the constant relief of thermal expansion This is an unacceptable condition and must be corrected It is recommended that any devices installed which could create a closed system have a by pass and or the system have an e...

Page 15: ...the valve see Figure 26 No valve or other obstruction is to be placed between the relief valve and the tank Do not connect tubing directly to discharge drain unless a 6 inch 15 cm air gap is provided To prevent bodily injury hazard to life or property damage the relief valve must be allowed to discharge water in quantities should circumstances demand If the discharge pipe is not connected to a dra...

Page 16: ...serving the water heater and A drip leg sediment trap ahead of the gas control valve thermostat to help prevent dirt and foreign materials from entering the gas valve A flexible gas connector or a ground joint union between the shut off valve and control valve to permit servicing of the unit Be sure to check all the gas piping for leaks before lighting the water heater Use a soapy water solution n...

Page 17: ...S BODILY INJURY OR PROPERTY DAMAGE If you have any questions or doubts consult your gas supplier or gas company Read and follow detailed conversion instructions located on the water heater and also in the instruction manual in their entirety before starting the conversion Conversion kit with necessary parts are in a bag attached to the drain valve FOR 30 GALLON HEATER Orifice size 40 for Natural 5...

Page 18: ...t after several tries depress and turn the gas control knob clockwise to OFF and call the gas supplier Step 15 Check for gas leaks with only pilot flame burning using soapy water solution not a match or open flame Check for gas leaks at fittings F and G see Figure 34 page 19 and at fittings J see Figure 31 page 19 Step 16 Make sure temperature adjustment dial is turned clockwise in its lowest posi...

Page 19: ...s consult your gas supplier or gas company To convert from Propane L P gas to Natural gas follow the Fuel Conversion Instructions From Natural Gas to Propane L P Gas section except in Step 5 use orifice E marked NAT In Step 6 use pilot orifice G brass color and in Step 8 turn control screw B in Figure 12 clockwise to stop Screw must be in OUT position for Natural Gas See Instruction Label for orif...

Page 20: ...20 ...

Page 21: ...ards HOTTER WATER CAN SCALD Water heaters are intended to produce hot water Water heated to a temperature which will satisfy space heating clothes washing dish washing and other sanitizing needs can scald and permanently injure you upon contact Some people are more likely to be permanently injured by hot water than others These include the elderly children the infirm or physically mentally handica...

Page 22: ...ydrogen sulfide gas dissolved in the water The smell is the result of four factors which must all be present for the odor to develop a A concentration of sulfate in the supply water b Little or no dissolved oxygen in the water c A sulfate reducing bacteria which has accumulated within the water heater this harmless bacteria is nontoxic to humans d An excess of active hydrogen in the tank This is c...

Page 23: ...ATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE Contact a qualified installer or service agency to replace a flooded water heater Do not attempt to repair the unit It must be replaced At least once a year a visual inspection should be made of the main burner and pilot burner see Figure 37 PERIODIC MAINTENANCE You should check for sooting Soot is not normal and will impair proper combustion Soot build...

Page 24: ... from tank Refer to Draining for proper procedures Close drain valve Remove old anode rod 4 Use Teflon tape or approved pipe 5 sealant on threads and install new anode rod Turn on water supply and open nearby 6 hot water faucet to purge air from water system Check for any leaks and immediately correct any if found Restart the water heater as directed under Operating Your Water weater See the Repai...

Page 25: ... start up after installation and when incoming water is cold H Water in the water heater bottom or on the floor may be from condensation loose connections or the relief valve DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken Leakage from other appliances water lines or ground seepage should also be checked To check wh...

Page 26: ...dial not positioned correctly Refer to LIGHTING INSTRUCTIONS Pilot orifice clogged Clean or replace pilot orifice Pinched or clogged pilot tube Replace pilot tube Main gas supply off Turn on main gas shut off valve Heater not lit or thermostat not on Refer to LIGHTING INSTRUCTIONS Thermostat set too low Refer to TEMPERATURE REGULATION Heater undersized Reduce the hot water use Low gas pressure Con...

Page 27: ...tion 24 Temperature Pressure Relief Valve 25 Thermocouple 26 Thermostat Shield 27 Vent Cap These parts available at most hardware stores Not Shown Now that you have purchased this water heater should a need ever exist for repair parts or service simply contact the company it was purchased from or direct from the manufacturer listed on the rating plate on the water heater Be sure to provide all per...

Page 28: ...28 Copyright 2009 A O Smith Water Products Company All rights reserved ...

Page 29: ...28 Copyright 2009 A O Smith Water Products Company Tous droits réservés ...

Page 30: ...lier de fi xation 23 Isolation T P 24 Soupape de décharge de température et de pression 25 Thermocouple 26 Écran de thermostat 27 Capuchon de ventilation Ces pièces sont disponibles dans la plupart des quincailleries Non illustré Maintenant que vous avez fait l acquisition de ce chauffe eau si jamais vous avez besoin de pièces de rechange ou de service communiquez simplement avec l entreprise où v...

Page 31: ... du pilote obstruée Nettoyez ou remplacez la buse du pilote Tube du pilote rétréci ou obstrué Remplacez le tube du pilote Alimentation principale en gaz fermée Ouvrez la soupape d arrêt de gaz principale Chauffe eau pas allumé ou thermostat pas en marche Référez aux INSTRUCTIONS D ALLUMAGE Thermostat est réglé trop bas Référez à RÉGULATION DE LA TEMPÉRATURE Chauffe eau sous dimensionné Réduisez l ...

Page 32: ...s vapeurs d eau qui peuvent se condenser sur les surfaces plus froides du réservoir Des gouttelettes se forment et dégouttent sur le brûleur ou se répandent sur le plancher Ceci est commun au moment du démarrage après l installation et lorsque l eau qui entre est froide H L eau dans le bas du chauffe eau ou sur le plancher peut provenir de la condensation de connexions pas assez serrées ou de la s...

Page 33: ...pproprié sur le fi letage et installez la nouvelle tige d anode Ouvrez l alimentation en eau et ouvrez un 6 robinet d eau chaude situé tout près pour purger l air du système d eau Vérifi ez toutes fuites et Corrigez les immédiatement Redémarrez le chauffe eau tel qu indiqué sous Fonctionnement de votre chauffe eau Voir l illustration des pièces de rechange pour l emplacement de la tige d anode FON...

Page 34: ...atement détectable Toutefois sur une période de temps un chauffe eau inondé créera des conditions dangereuses qui pourraient causer la MORT DES BLESSURES CORPORELLES SÉRIEUSES OU DES DOMMAGES MATÉRIELS Communiquez avec un installateur qualifi é ou avec une agence de service pour remplacer un chauffe eau submergé par l eau Ne tentez pas de réparer l appareil Il doit être remplacé Au moins une fois ...

Page 35: ... odeur d œufs pourris dans l eau chaude Cette odeur est dérivée du gaz de sulfure d hydrogène dissout dans l eau L odeur est le résultat de quatre facteurs qui doivent tous être présents pour qu elle se développe a Une concentration de sulfate dans l alimentation d eau b Très peu ou pas d oxygène dissous dans l eau c Une bactérie qui réduit le sulfate dans le chauffe eau cette bactérie inoffensive...

Page 36: ...eau chauffée à une température adéquate pour le chauffage d un espace pour le lavage du linge le lavage de la vaisselle et autres besoins sanitaires peut ébouillanter et blesser de façon permanente si contact Certaines personnes sont plus à risque d être blessées de façon permanente par l eau chaude que d autres Celles ci incluent les personnes âgées les enfants les handicapés ou les personnes att...

Page 37: ...qu à ce qu il s arrête Poussez le bouton de contrôle du gaz légèrement et tournez à droite jusqu à ARRÊT VOIR FIGURE A Enlevez la porte extérieure du brûleur située sous le contrôle du gaz Cet appareil est équipé d un allumeur de pilote à bouton poussoir qui est utilisé pour allumer le pilote Repérez l allumeur sur le contrôle du gaz Le pilote est situé en avant du brûleur Il peut être repéré en r...

Page 38: ...onvertir du gaz propane P L au gaz naturel suivez les instructions de conversion d alimentation de la section Du gaz naturel au gaz propane P L sauf que dans l Étape 5 utilisez la buse E identifi ée NAT Dans l Étape 6 utilisez la buse G de couleur cuivre et dans l Étape 8 tournez la vis de contrôle B dans la fi gure 12 vers la droite pour arrêter La vis doit être dans la position OUT pour le gaz n...

Page 39: ...outon de contrôle vers la droite à la position ARRÊT et appelez le fournisseur de gaz Étape 15 Vérifi ez les fuites de gaz avec uniquement la fl amme du pilote qui brûle en utilisant une solution d eau savonneuse et non une allumette ou une fl amme ouverte Vérifi ez les fuites de gaz aux raccords F et G voir Figure 34 page 19 et aux raccords J voir Figure 31 page 19 Étape 16 Assurez vous que le ca...

Page 40: ...s détaillées de conversion situées sur le chauffe eau et aussi le manuel d instructions au complet avant de débuter la conversion Une trousse de conversion avec les pièces nécessaires se trouve dans un sac attaché à la soupape de vidange POUR UN CHAUFFE EAU DE 30 GALLONS Grosseur de la buse 40 pour Naturel 52 pour Propane P L si converti Taux de propane 30 000 BTU POUR UN CHAUFFE EAU DE 40 GALLONS...

Page 41: ...cilement accessible dans la conduite d alimentation en gaz qui dessert le chauffe eau et Un point de purge trappe à sédiments avant la soupape de contrôle du gaz thermostat pour empêcher la saleté et les matières étrangères d entrer dans la soupape de gaz Un raccord au gaz fl exible ou un raccord à joint rodé entre la soupape d arrêt et la soupape de contrôle pour permettre le service de l unité A...

Page 42: ...tre soupape ou obstruction ne doit être présente entre la soupape de décharge et le vase Ne connectez pas le tube directement au drain de décharge à moins qu un espace d air de 15 cm 6 pouces soit prévu Pour éviter les blessures corporelles les risques de mort ou les dommages matériels la soupape de décharge doit pouvoir laisser l eau s écouler en grande quantité si les circonstances l exigent Si ...

Page 43: ...e de la température et de la pression n est pas faite pour une décharge constante d expansion thermique Ceci est une condition inacceptable et doit être corrigée Il est recommandé que tous les dispositifs installés qui pourraient créer un système fermé aient une dérivation et ou que le système ait un vase d expansion pour relâcher la pression accumulée dans l eau par l expansion thermique Des vase...

Page 44: ...méables lors de la manutention Ne fumez mangez ou buvez pas lors de la manutention Lavez vous complètement après la manutention et avant de manger Portez une protection pour les yeux lors de la manutention Si avalé buvez de l eau ne faites pas vomir et appelez un médecin ou le centre antipoison immédiatement Si inhalé allez à l air frais et consultez un médecin si les malaises persistent En cas de...

Page 45: ...6 cm 4 po La trousse optionnelle N 9002987005 contient un capuchon de ventilation PVC Schedule 40 45 de 10 16 cm 4 po avec écran et deux colliers pour le mur de 10 16 cm 4 po TOUS LES MODÈLES 1 La tuyauterie et les raccords PVC ABS ou CPVC Schedule 40 sont des matériaux acceptables pour le système d entrée d air de ventilation 2 Le système d entrée d air de ventilation doit terminer de façon horiz...

Page 46: ...s librement 3 Passez le tuyau extérieur de l assemblage de la trémie de cheminée jusqu à une longueur qui dépassera d au moins 5 08 cm 2 po sous la fi nition du plafond avant d installer l assemblage de la trémie de cheminée voir Figure 14 FIGURE 14 4 Passez la trémie de cheminée à travers les ouvertures du toit et du plafond Le solin de la trémie de cheminée s incline de 22 6 pour une utilisation...

Page 47: ... FIXER LE CHAUFFE EAU AU PLANCHER ET AU MUR Le chauffe eau doit être fi xé sécuritairement au plancher et au mur du local avec les trois supports de fi xation et vis empaquetés dans l emballage avec le chauffe eau Les deux petits supports sont utilisés pour attacher le chauffe eau au plancher et le plus grand support est utilisé pour fi xer sécuritairement le dessus du chauffe eau au mur Parce qu ...

Page 48: ... ou la soupape de décharge de température et de pression Ne laissez pas l isolation arriver en dedans de 50 8 mm 2 po du plancher afi n de prévenir un blocage du fl ux d air de combustion au chauffe eau Ne couvrez pas le manuel d instructions Gardez le sur le côté du chauffe eau ou tout près pour référence future Obtenez des nouvelles étiquettes d avertissement et d instructions du fabricant et pl...

Page 49: ...es dommages physiques par un véhicule en mouvement Ce chauffe eau ne doit pas être installé directement sur du tapis Le tapis doit être protégé avec un panneau de métal ou de bois sous l appareil et doit dépasser la largeur et la profondeur de l appareil d au moins 76 2 mm 3 pouces dans toutes les directions ou si l appareil est installé dans une alcôve ou un placard le plancher en entier doit êtr...

Page 50: ...81 28 cm carrés 32 pouces carrés Les autres appareils au gaz dans la maison exigeront des ouvertures d air libre supplémentaires consultez ces fabricants pour les mesures exactes voir Figure 3 FIGURE 3 Si la maison préfabriquée est installée par dessus un sous sol ou un vide sanitaire l air de combustion doit provenir de l extérieur de la maison préfabriquée La tuyauterie d air de combustion peut ...

Page 51: ...i incluent les personnes âgées les enfants les handicapés ou les personnes atteintes d une défi cience physique mentale Si quiconque qui utilise l eau chaude dans votre maison fait partie de ces groupes ou s il existe un code local ou une loi provinciale qui exige une température d eau quelconque au niveau du robinet d eau chaude alors vous devriez prendre des précautions particulières En plus d u...

Page 52: ...oupape d arrêt d entrée d eau O Entrée d eau froide P Raccord d admission fi leté Q Soupape de décharge de température et de pression R Plaque signalétique S Défl ecteur de conduit d air T Soupape de contrôle du gaz Thermostat U Soupape de vidange V Veilleuse d allumage et brûleur principal W Conduit d air X Assemblage du conduit d air Y Bac de récupération en métal Z Écran de thermostat en option...

Page 53: ...design ce chauffe eau au gaz est certifié par CSA INTERNATIONAL sous la norme nationale américaine norme de l Association canadienne de normalisation pour les chauffe eau au gaz pour Installation dans des maisons préfabriquées ANSI Z21 10 1 CSA4 1 édition courante SE PRÉPARER POUR L INSTALLATION 1 Lire la section Sécurité générale en premier à la page 3 de ce manuel puis lire attentivement le manu...

Page 54: ...3 SÉCURITÉ GÉNÉRALE ...

Page 55: ...taller des chauffe eau au gaz et pour travailler avec le gaz naturel B P pour installer les conduites d évacuation de gaz air ainsi que les composants au gaz Ses employés et ses représentants doivent aussi avoir une connaissance appropriée du métier et doivent bien connaître les exigences du Code d installation du gaz naturel et du propane CSAB149 1 édition courante puisqu il concerne l installati...

Page 56: ...TIE DOIVENT ÊTRE ADRESSÉES AU FOURNISSEUR LOCAL DE QUI LE CHAUFFE EAU A ÉTÉ ACHETÉ SI VOS QUESTIONS DEMEURENT SANS RÉPONSE VEUILLEZ ÉCRIRE À L ENTREPRISE LISTÉE SUR LA PLAQUE SIGNALÉTIQUE SUR LE CHAUFFE EAU CHAUFFE EAU AU GAZ RÉSIDENTIELS À VENTILATION DIRECTE Pour votre sécurité UN ODORISANT EST AJOUTÉ AU GAZ UTILISÉ PAR CE CHAUFFE EAU POUR USAGE UNIQUEMENT AVEC LES SYSTÈMES DE VENTILATION FOURNI...

Reviews: