background image

A.E.B.  INDUSTRIALE s.r.l.

Via Brodolini, 8 - 40056  Crespellano (Bo) - ITALIA
Tel. + 39 051 969870 - Fax. + 39 051 969725
Internet: www.dbtechnologies.com
E-mail: [email protected]

MANUALE D’USO

USER MANUAL

COD. 420120171 REV.1

EXIT

MENU

CURSOR

ENTER

PARAMETER

MUTE

MENU

4

3

MUTE

2

1

MUTE

MUTE

OUTPUTS

SIGNAL

-12dB

-6dB

-3dB

LIMIT

TECHNOLOGIES

DIGITAL LOUDSPEAKER PROCESSOR

DSX 2040 

1

CONNECTIONS

SIGNAL

MENU

-12dB

-6dB

-3dB

LIMIT

2

MUTE

MUTE

INPUTS

USB

RS232

d B      T e c h n o l o g i e s
P 0 2    _ _ _ _ _ _ _ _ _ _ _ _

DSX 2040 

DSX 2040 

LOUDSPEAKER MANAGEMENT SYSTEM

LOUDSPEAKER MANAGEMENT SYSTEM

d

B

Summary of Contents for DSX 2040

Page 1: ...SO USER MANUAL COD 420120171 REV 1 EXIT MENU CURSOR ENTER PARAMETER MUTE MENU 4 3 MUTE 2 1 MUTE MUTE OUTPUTS SIGNAL 12dB 6dB 3dB LIMIT TECHNOLOGIES DIGITAL LOUDSPEAKER PROCESSOR DSX 2040 DSX 2040 1 CONNECTIONS SIGNAL MENU 12dB 6dB 3dB LIMIT 2 MUTE MUTE INPUTS USB RS232 dB Technologies P02 ____________ DSX 2040 DSX 2040 LOUDSPEAKER MANAGEMENT SYSTEM LOUDSPEAKER MANAGEMENT SYSTEM dB ...

Page 2: ...ONTENUTE PARTI RIPARABILI DALL UTENTE AFFIDARE LE RIPARAZIONI A PERSONALE QUALIFICATO ATTENZIONE PER RIDURRE IL RISCHIO DI INCENDIO O DI SCOSSA ELETTRICA NON ESPORRE QUESTO APPARECCHIO ALLA PIOGGIA O ALL UMIDITÀ Questo simbolo dove compare ha lo scopo di avvisare l utente di presenza di tensione pericolosa all interno del prodotto che può essere di portata sufficiente a costituire un rischio di sc...

Page 3: ...l attivazione e disattivazione dei canali di ingresso e uscita L accensione del LED rosso del pulsante indica che il canale è in stato di MUTE Quando i pulsanti Menu oppure Menu 7 sono premuti i tasti Mute selezionano il corrispondente canale per il menu visualizzato sul display LCD ed è segnalato dall accensione del LED verde presente sotto il tasto L ultimo menu modificato verrà visualizzato sul...

Page 4: ...i sotto il tasto Mute si accendono quando i canali sono collegati Qualsiasi modifica di dati per il canale selezionato verrà applicata anche ai canali collegati a questo Per annullare il collegamento de selezionare il canale desiderato tenendo premuto i tasti Menu o Menu oppure premere il tasto Exit per de selezionare tutti i canali Collegamento del canale al tasto Mute del canale dBTechnologies D...

Page 5: ...Q 1 LEVEL 0 00dB I1 ______ GEQ 1 GEQ 1 f 20 I1 ______ GEQ 1 LEVEL 0 00dB f 20 I1 ______ GEQ 1 BYPASS Off 6 4 INGRESSO USCITA TYPL Per il crossover sono disponibili 3 tipi di filtro passa alto Butterworth Linkwitz Riley oppure Bessel FRQL La frequenza di taglio del filtro passa alto varia da 20 a 30KHz sia in passi di 1Hz che di 1 36 di ottava I passi di frequenza possono essere selezionati nel Sys...

Page 6: ... del limiter varia da 0 3 to 1ms a passi di 0 1ms poi varia da 1 a 100ms a passi di 1ms RELEASE Il tempo di rilascio del limiter può essere impostato a 2X 4X 8X 16X oppure 32X dell attack time 6 8 ASSEGNAZIONE SORGENTE INGRESSO IN1 2 Imposta il canale di ingresso per il canale di uscita selezionato Per ogni ingresso è possibile variare il livello sorgente da OFF a 0 dB Se vengono abilitati più can...

Page 7: ... deve spegnere e riaccendere l unità BAUD RATE questo parametro imposta ilvalore di baud rate della comunicazione seriale Xconsole utilizza una baud rate di 115 200 tale valore è ottimizzato per la maggior parte degli utilizzi DEVICE ID Questo controllo assegna un ID identificatore da 1 a 16 del dispositivo Questo ID è utile solo quando una rete di più di unità viene utilizzata in combinazione con...

Page 8: ...Limit THRESH 20 20 0 5 dBu Limiter AttackTime Limit ATTACK 0 3 100 0 1 1 ms Limiter Tempo rilascio Limit RELEASE 2 4 8 16 32XAttack time Sorgente Source 1 2 3 4 5 6 7 8 Off 15 0 25 dB Nome canale Name NAME 6 caratteri SYSTEM Secure PASSWORD ____ 7 7 BLOCCO DI SICUREZZA Il DSX 2040 permette all utente di salvaguardare l unità ed evitare modifiche indesiderate al setup Al fine di bloccare o sbloccar...

Page 9: ...si analogici 3 poli Femmina XLR Uscite analogiche 3 poli Maschio XLR RS 232 Femmina DB 9 USB Tipo B Power Presa standard IEC Generale Alimentazione 90 240 VAC 50 60Hz Dimensioni 483x44x229 mm 1U Peso 4 5 kg Parametri di ControlloAudio Guadagno MIC 0 a 45dB in passi di 3dB Guadagno 40 a 15dB in passi di 0 25dB Polarità Ritardo Fino a 650ms per I O Equalizzatori 8 per I O Tipo Parametrici Hi shelf L...

Page 10: ...comes damaged contact technical assistance and request replacement Do not use cables other than supplied cables Disconnection from the mains The power mains connector is the device to disconnect from the mains This device must be easily accessible after installation VDE CAUTION TO PREVENT ELECTRICAL SHOCK DO NOT REMOVE COVER AVIS RISQUE DE CHOCH ELECTRIQUE NE PAS OUVRIR English English English use...

Page 11: ...Buttons Mute or un mute input and output channels When an input channel is muted a red LED will come on for indication When the Menu or Menu key is held down the Mute Buttons selects the corresponding channel for the LCD menu display and is acknowledged by a green LED below the button The last modified menu will be displayed on the LCD Multiple channels can be linked or unlinked by pushing the des...

Page 12: ...e group Input or Output group can be selected to link the channels together The green LEDs below the Mute buttons are lit for the linked channels Any modification of the data for the selected channel will be applied to the linked channels as well To cancel the linking simply deselect the desired channel while the Menu or Menu key is still pressed or just press the Exit key to deselect all channels...

Page 13: ...B I1 ______ GEQ 1 GEQ 1 f 20 I1 ______ GEQ 1 LEVEL 0 00dB f 20 I1 ______ GEQ 1 BYPASS Off 6 4 INPUT OUTPUT CROSSOVER TYPL The 3 available filter types for the low frequency crossover point high pass are Butterworth Linkwitz Riley or Bessel FRQL The filter cut off frequency for the low frequency crossover point high pass ranges from 20 to 30kHz in either 1Hz steps or 1 36 octave steps The frequency...

Page 14: ...iter attack time ranges from 0 3 to 1ms in 0 1ms steps then ranges from 1 to 100ms in 1ms steps RELEASE The limiter release time can be set at 2X 4X 8X 16X or 32X the attack time 6 8 OUTPUT SOURCE IN1 2 This sets the input channel source for the current output channel It can be used to mix the input source in dB or disable it Off If more than one input sources are enabled they will be added togeth...

Page 15: ...unit for this settings to take effect BAUD RATE The sets the baud rate of the serial communication XConsole uses a baud rate of 115200 it should be left unchanged for most user DEVICE ID This control assigns a device ID from 1 to 16 to the unit This ID is only useful when a network of more than 1 unit is used in conjunction with 1 or more XConsole NETWORK ID This control assigns a network ID from ...

Page 16: ...shold Limit THRESH 20 20 0 5 dBu LimiterAttackTime Limit ATTACK 0 3 100 0 1 1 ms Limiter ReleaseTime Limit RELEASE 2 4 8 16 32XAttack time Source Source 1 2 3 4 5 6 7 8 Off 15 0 25 dB Channel Name Name NAME 6 characters SYSTEM Secure PASSWORD ____ 7 7 SECURITYLOCK The DSX 2040 enables the user to secure the unit and prevent undesired changes in the setup In order to lock or unlock the unit the use...

Page 17: ... pin Female XLR Analog Outputs 3 pin Male XLR RS 232 Female DB 9 USB Type B Power Standard IEC Socket General Power 90 240 VAC 50 60Hz Dimensions 19 x1 75 x9 483x44x229 mm Weight 10 lbs 4 5 kg Audio Control Parameters Mic Gain 0to 45dB in 3dB steps Gain 40 to 15dB in 0 25dB steps Polarity Delay Up to 650ms per I O Equalizers 8 per I O Type Parametric Hi shelf Lo shelf Phase 1 Phase 2 Gain 30 to 15...