Safety Warnings
!
Tools Required
Tools Required
Fittings Required
Genie
®
Direct Drive 752
Installation & Operation Instructions
Failure to abide by any of the safety warnings below may result in equipment failure or serious injury and death.
}
Do not exceed any equipment pressure ratings
}
The probe must be installed into the process line by means of the appropriate size female full port ball valve
}
Only the lowest wrench flats on the base, nearest to the NPT male threads, can be used when installing into the process ball valve
}
DO NOT
use the wrench flats on the packing adjustment nut, located on the top of the base, for installation into process ball valve.
}
Not designed for external fire.
}
Prior to use in a system, a properly sized relief device is to be installed which limits the use to 110% of the MAWP.
}
1-3/8” open end wrench
}
7/16” open end wrench
}
(2) 7/8” open end wrenches
}
1-3/16” open end wrench
}
Appropriate size female full port ball valve