Biogas analyser ABE_1500
Ver 002
ABE_1500
BIOGAS ANALYSER
User Manual
Page 1: ...Biogas analyser ABE_1500 Ver 002 ABE_1500 BIOGAS ANALYSER User Manual ...
Page 2: ...missione a terzi e la riproduzione di questa documentazione cosiccome lo sfruttamento del suo contenuto non è permesso se non autorizzato per iscritto Le infrazioni comporteranno una richiesta di danni Tutti i diritti sono riservati in particolare nel caso di brevetti Modifiche tecniche possibili ABE_1500 Are AB Energy registered trademarks All other product or system names are registered trademar...
Page 3: ... ANALOGIC INPUT CALIBRATION 23 B BATTERY RECHARGER 29 C CPU DATA CONFIGURATION 21 D DATA SALVAGE 20 G GENERAL WARNINGS 4 I INSTRUCTIONS FOR MANUAL 4 K KEYBOARD 14 M MEASURES CAMPS 30 N NUMERIC VISUALIZATION 16 S SCREEN 14 STRUCTURE 14 SUPERVISION SOFTWARE 10 T TECHNICAL NOTE 30 W WINDOW PASSWORD 20 ...
Page 4: ...ble use to employment estimated It applies qualified staffs which has received specific training If you wish others information or if you have particular problems that there isn t in this manual you ll have to ask necessary explanations to our factory 1 2 Instructions to use this manual In this manual there is the description how of put in service use and make preservation of this instrument We re...
Page 5: ...nd secondary electrical circuit Secure workings without errors ask accurate transport and professional store and also accurate preservation Advise This instrument is electric Before open case some parts of this instrument are accessible but that are parts in electrical voltage So only qualified staff can make some interventions on this instrument 1 5 Qualified staff Can verify in case of intervent...
Page 6: ... packing Please verify the integrity of supply Conserve packing for possible re shipping 1 8 Laws and arrangements Where possible for specification and production of this instrument it was based on European laws In case of use of this product outside application sphere of this laws and arrangements it must observe laws and arrangements of customer s Country 1 9 Conformity declaration Biogas analys...
Page 7: ...ide the instrument contains inflammable components above their explosion limit it must be take security measures with expert person Warning During collecting of poisonous or aggressive gas can happen that for a defect of gas conducts quantity of sample gas amass in the instrument To anticipate an explosion or poisonous warning the instrument must be wash with inactive gas 2 3 Gas connections to in...
Page 8: ... whit percentage of oxygen less of 5 it augments until 4 5 years in case of clean and not damp gas 3 3 Methane Sensor Carbon Anhydride Carbon Monoxide The sensory utilize a source of impulsive emission of infrared to low temperature Methane Carbon Anhydride and Carbon Monoxide presents an high coefficient of absorbition of infrared light the sensory read this attenuation when inside of measures ro...
Page 9: ...ntroller configuration and transfer dates compatibles Microsoft Excel ABE_570 Case for ABE_1500 ABE_580 Catalitic sensor for the measure of the concentration of hidrogen sulphide in the concentration from 0 to 500 ppm ABE_581 Catalitic sensor for the measure of the concentration of ammonia in the concentration from 0 to 1000 ppm ABE_582 Catalitic sensor for the measure of the concentration of carb...
Page 10: ...e information of pack make referred to software manual Configuration software The software permits reading and configuration of function parameters of instrument and the visualization of reading Analyser has one serial com 232 standard port galvanic insulated The isolation permits the connection with external instruments that can be in a different potential On this port you can connected the super...
Page 11: ...Use instructions Biogas analyser ABE_1500 11 3 6 Case ABE_570 Plastic case for transport and protect the gas analyzer ABE_1500 it has transparent membrane for visualize the screen Case ABE_570 ...
Page 12: ...Sensor life More than 2 years Operating Temperature 20 C 50 C Operating Humidity 15 90 RH Operating Pressure 1 atm 10 Table of the sensitivity of the sensor compared to other gas Gas Concentration ppm Concentration equals of H ppm H2S 100 100 CO 100 5 CO2 5000 0 H 1000 7 15 S 30 7 C2H4 100 0 3 2 CL 10 0 CH4 5000 0 N 10 0 3 N2 10 3 NH3 100 0 CH3CH2OH 100 7 3 ...
Page 13: ...nsor life More than 2 years Operating Temperature 30 C 50 C Operating Humidity 15 90 RH Operating Pressure 1 atm 10 Table of the sensitivity of the sensor compared to other gas Gas Concentration ppm Concentration equals of H ppm NH3 100 100 H2S 10 30 H 1000 0 CH4 5000 0 CO2 5000 0 SO2 10 15 N2O 20 0 NO2 20 2 CO 200 0 C2H5OH 100 0 C2H4O 1000 0 CL 10 0 ...
Page 14: ...mits to see at the same time all measures made by analyser in numerical form In the main page you can change the display contrast with the up and down arrows KEYBOARD Web keyboard numerical with more special functions taste in relief pressure squash a boll of steel witch produce taste sensation By that it s possible local direction of all functionalities of instrument High protection grade that pe...
Page 15: ...uring that the analyzer warm up the sensors and inizialise the system At the end of this fase the system will move automatically to the main page If the battery is too low the system will turn off immediately If last calibration was done more than two months ago a warning will appear To turn off the analyzer you have to press the segrete key below the biotecnogas name for more than 3 seconds Warm ...
Page 16: ...ht are showed date and time the internal watch work also when the analyser is off o The percentage value of concentration of methane oxygen dioxide carbon read by analyser o The value of monoxide of carbon ammonia hydrogen sulfide read by instrument o The percentage of LEL low explosiviti level o Atmospheric pressure differential pressure and temperature of gas o The bar graf with the charge batte...
Page 17: ... Push the esc key to exit form the insert mode KEY CHARACTERS 0 0 SPACE 1 1 _ 2 2 A B C 3 3 D E F 4 4 G H I 5 5 J K L 6 6 M N O 7 7 P Q R S 8 8 T U V 9 9 W X Y Z DEL DELETE LAST CHART ESC EXIT FROM INSERT MODE UPPER CASE LOWER CASE ENTER CONFERM INPUT DATA Press F3 key to show the input password page the password is 123456 As soon as you write the right password the system move automatically to th...
Page 18: ... key and using the halfanumeric keyboard insert the new ID at the end confirm it with enter key If you want to insert a new weel ID press F3 key a new ID line is show insert the name and confirm with enter The new ID will be add and the ned of the list into the instrument Press the F6 key to turn on or turn off the back ligh of the display Press the pump key to turn on the vacum pump inside the an...
Page 19: ...ll ID name In the main page press the key F2 to show the following page Main page Write the ID name with the alfanumeric keyboard of the analyzer Push enter key to confirm the ID name Now in the main page the ID just write will be show in the ID name location ...
Page 20: ...favourably of versions When you are inside of configuration you can move form one page to another page by tastes F1 F2 F3 For exit of configuration and come back on visualization pages you must push taste ESC 4 2 Data salvage Inside configuration pages all modification is saved only in the temporary memory that is loose with the extinguishment To make permanent salvage of new values push taste PUM...
Page 21: ... ON for active the bip or 0 OFF to inactive it Factory parameters permit the renewal of all factory analyser parameters that if not saved will be maintained until analyser off Date sow date and time laid selecting the voice DATA it s possible impost the date and the time correct writing the new data in the formed ddMMyyhhmmss Then press ENTER Delete log data Chosing the parameter DELETE LOG DATA a...
Page 22: ...d if set to 0 OFF the reading is disable CO IR enabled if set to one ON the carbon monoxide IR sensor reading is enabled if set to 0 OFF the reading is disable H2S enabled If set to one ON the H2S sensor reading is enabled if set to 0 OFF the reading is disable NH3 enabled If set to one ON the NH3 sensor reading is enabled if set to 0 OFF the reading is disable CO enabled Ab set to one ON the carb...
Page 23: ...libration Calibration of sensors must be repeat each 60 days for guarantee declared precision Instrumentation necessary for analogic input calibration 1 Cylinder with zero sample gas Nitrogen 2 Cylinder with span gas 5 oxygen rest nitrogen 3 Cylinder with span gas 44 carbon anhydride 1 carbon monoxide 55 methane 2 Necessary for calibration of oxygen sensory 3 Necessary for calibration of infrared ...
Page 24: ... terms of desiderate measure camp for channel oxygen value Reading value show value reading at moment variable only in reading 4 6 Calibration pass Analogic input For calibration of each channel 1 Connect zero signals on entry of analogic input go on channel zero value and write zero value 2 Press left arrow to take and associate value reading by converter with introducing value 3 Connect span sig...
Page 25: ...at least 5 minutes for sensory stabilization 3 Press left arrow taste so the analyser read converter value and connect 0 to oxygen value 4 Write Channel 1 high value 5 5 Connect cylinder whit 5 of oxygen and rest of nitrogen to instrument whit a flux of 5 litres Then wait at least 5 minutes for sensory stabilization 6 Press left arrow taste and analyser read converter value and connects to 5 oxyge...
Page 26: ... arrow taste so the analyser read converter value and connect 0 to carbon monoxide value 8 Connect cylinder whit 55 of methane 44 of carbon anhydride and 1 of carbon monoxide to instrument whit a flux of 5 litres Then wait at least 2 minutes for sensory stabilization 9 Write Zero Value CH4 55 10 Write Zero Value CO2 44 11 Write Zero Value CO 10000 12 Press left arrow taste and analyser read conver...
Page 27: ...ress the pump key and confirm with enter Is possible do the same pushing the key in the main page Absolute presure sensor calibration Connect the pipe to the plug and leave it free not connect to anything but in free air From the main page push F3 key and go to the password page write the password and then F2 key With arrow down go to absolute presure zero line write the value of the absolute pres...
Page 28: ...enter key If you want to insert a new weel ID press F3 key a new ID line is show insert the name and confirm with enter The new ID will be add and the ned of the list into the instrument Press F1 key to return to the main screen Gas Analisys mesure example 1 Connect the pipe with the filter between the well and the right plug of the analyser the arrow on the plastic case follow the gas flow 2 Inse...
Page 29: ...case tru the plug and push the red button on the recharger the yellow led will turn on and stay so till the bactery is fully recharged When the bactery are completely down the recharded time is at least 2 hours The analyser control at any time the state of the bactery and turn itself off the the battery are too low before do that advise the operator with beep and a writing warning ADVISE Never lea...
Page 30: ...lution O2 0 25 Volum 1 Ch4 0 100 Volum 1 5 CO2 0 100 Volum 1 5 CO 0 20000 ppm 1 5 NH3 0 1000 ppm 3 H2S 0 500 ppm 3 Absolute pressure 100 1200 mBar 2 Relative pressure 200 0 mBar 2 Temperature Sensor 10 100 C 0 5 C Flow sensor 0 6 40 m s Vacum pump 0 2000 cm min Vacum pump 100 450 mBar 6 2 Memory The analyzer con memorize till 800 well ID names and 2349 log record acquisition ...
Page 31: ...oncentration hurtful for health In case of not appropriate gas lacing can be verify warning of accident due to poison gas fuels or explosives Attention Components and electrical modules inside this instrument must be protected against electric discharges For this one must take many protective measures anywhere they were made tested shipped and installed ...
Page 32: ... case of maritime transport the instrument must be warp up in a polystyrene film 0 02mm thick For this shipping mode the case must be dressed with tarpaper 6 5 Address for re shipping Technical assistance for technical assistance Tel 39 015 9842253 Fax 39 015 9233243 info abenergy it Repairs For a rapid cancel of damage causes please send the instrument to the following address AB ENERGY S R L VIA...
Page 33: ...the essential requirements of the following applicable European Directives cosi come originariamente consegnati rispondono ai requisiti essenziali delle seguenti applicabili Direttive Europee Electromagnetic Compatibility Directive 2004 108 EC and conform with the following product standards e sono conformi ai seguenti standard di prodotto EMC EN 61131 1 EN 61131 2 EN 61000 4 2 EN 61000 4 3 EN 610...