![8e6 Technologies TAR User Manual Download Page 67](http://html.mh-extra.com/html/8e6-technologies/tar/tar_user-manual_445774067.webp)
C
ONFIGURATION
S
ECTION
C
HAPTER
2: C
USTOM
G
AUGE
S
ETUP
, U
SAGE
8
E
6 T
ECHNOLOGIES
,
T
HREAT
A
NALYSIS
R
EPORTER
U
SER
G
UIDE
55
When adding a gauge group, you need to do the following:
• Name the gauge, and specify limit and timespan values
• Synchronize all library categories from the source R3000
with the TAR unit
• Select library categories for the gauge to monitor
• Assign user groups whose end users’ Internet/network
activity will be monitored by the gauge
• Verify limit values for library categories included in the
gauge, and specify the library category method(s) to be
used by the gauge
Add Gauge Information
In the Gauge Information box:
1. Type in at least four characters for the
Gauge Name
using upper and/or lowercase alphanumeric characters,
and spaces, if desired.
2. Type in the
Lower Limit Value
of the floor for any gauge
activity. The recommended value is
0
(zero).
3. Type in the
Upper Limit Value
of the ceiling for gauge
activity. The recommended value is
200
. This can be
adjusted after using TAR for awhile and evaluating
activity levels at your organization.
4. Type in the
Timespan in minutes (1-60 Only)
for
tracking gauge activity; usually
15
minutes. The
timespan will always keep pace with the current time
period, so that if a timespan of 15 minutes is specified,
the gauge will always reflect the most recent end user
activity from the past 15 minutes.
Summary of Contents for TAR
Page 1: ... Threat Analysis Reporter USER GUIDE Model TAR Release 1 3 00 Manual Version 1 01 ...
Page 2: ...ii 8E6 TECHNOLOGIES THREAT ANALYSIS REPORTER USER GUIDE ...
Page 4: ...iv 8E6 TECHNOLOGIES THREAT ANALYSIS REPORTER USER GUIDE ...
Page 216: ...APPENDICES SECTION APPENDIX D 204 8E6 TECHNOLOGIES THREAT ANALYSIS REPORTER USER GUIDE ...