3.4.2 Remote Outputs
Remote Outputs icon refers to your remote Output Module. This module is controlled by
your SG and over the network.
It will be green if the button has set outputs, or white if none are set.
Every row represents an OM. You can daisy chain up to 6 modules for a maximum of 96
outputs. Rows 1 trough 16 represent the first OM. Rows 17 trough 32 represent the first
OM and so forth.
As with the local outputs, there are four possible states:
This output is unused by any button.
This output is used by some other button. If you hold your mouse over this icon it will tell
you the exact button using it.
This output is switched on when you click the button.
This output is explicitly switched off when you click the button. Used in special cases
with some 4 Square configurations.