Level 7000
Level 7000 is an error code for a short circuit. It means that there is some dirt, water, metal
shavings or admixtures inside the sensor’s tubes. All these can be highly conductive and the sensor
is designed to work in an environment with low conductivity (such as fuel).
Fig. 88
Level 7000
You need to clean the tubes of the sensor - preferably with compressed air blowing the
sensor’s tubes via the drainage hole. Clean the tank and replace the fuel if necessary.