background image

   

 

 

 

 

 

IMC100-2T1F-1D 

Industrial Media Converter 

User Manual 

Version  01 

Issue Date: 2019-01-28 

 
 
 
 
 

Industrial Ethernet Communication Solutions Expert                                                              3onedata Co., Ltd. 

Summary of Contents for IMC100-2T1F-1D

Page 1: ...IMC100 2T1F 1D Industrial Media Converter User Manual Version 01 Issue Date 2019 01 28 Industrial Ethernet Communication Solutions Expert 3onedata Co Ltd...

Page 2: ...product service or features should be constrained by 3ondedata commercial contracts and clauses The whole or part product service or features described in this document may beyond purchasing or using...

Page 3: ...aiwangxin High Technology Industrial Park Song Bai Road Nanshan District Shenzhen 518108 China Technology support tech support 3onedata com Service hotline 86 400 880 4496 E mail sales 3onedata com Fa...

Page 4: ...nance On site technical support and maintenance staff Hardware engineer Text Format Convention Format Description Words with represent the interface words e g The port number Multi level path is separ...

Page 5: ...age Pay attention to the notes on the mark improper operation may cause personal injury Make a necessary supplementary instruction for operation description Configuration operation or tips for device...

Page 6: ...EM STATUS 4 2 1 BASE INFOR 4 2 2 PORT INFOR 6 3 SYSTEM CONFIG 8 3 1 PORT SETTING 8 3 2 VLAN 10 3 3 COM SETTINGS 10 3 4 IP FILTERING 13 3 5 MAC FILTERING 14 3 6 RELAY WARNING 16 3 7 STORM 17 4 SYSTEM T...

Page 7: ...Software System Requirements CPU Above Pentium 586 Memory Above 128MB Resolution Above 1024x768 Color Above 256 color Browser Above Internet Explorer 6 0 Operating System Windows XP Windows 7 1 2 Sett...

Page 8: ...rrent PC is 192 168 5 60 change the network segment 5 of the IP address to 1 Operation Steps Amendment steps as follows Open Control Panel Network Connection Local Area Connection Properties Step 1 In...

Page 9: ...window Notes The default username and password are admin please strictly distinguish capital and small letter while entering Default username and password have the administrator privileges WebServer...

Page 10: ...ation such as hardware version firmware version and MAC address etc as well as network settings Operation Path Open in order Main Menu System Config System Information Interface Description 1 Basic In...

Page 11: ...Network Set Network Set interface as follows Main elements configuration description of Network Set interface Interface Elements Description Use the following IP address It represents that enabling ma...

Page 12: ...atically obtain DNS server address Configure the acquisition form of DNS server address as automatic acquisition Notes When IP address is manual configuration this option becomes gray and is not optio...

Page 13: ...tate Support two kinds of Port State Enable Disable Link State Support two kinds of Link State Link UN link Rate duplex Rate duplex Auto 10M half duplex 10M full duplex 100M half duplex 100M full dupl...

Page 14: ...ed duplex mode Flow control Jumbo frame status The speed duplex and flow control aimed at this port only works when the port is enabled The speed and duplex would be acquired via automatic negotiation...

Page 15: ...When the port state is enable it means this port is enabled which is no data forwarding and other options of this port would gray out and be unable to choose Speed Duplex Click the drop down list of S...

Page 16: ...ion of Vlan interface Interface Element Description VLAN Config VLAN Config column VLAN Support two kinds of State Enable Disable Notes Enable Vlan fiber port can communicate with copper port mutually...

Page 17: ...eter config Serial port Parameter config column Baud Rate bps Select baud rate of corresponding serial number Options include 600 1200 2400 4800 9600 19200 38400 57600 115200 Check Bit Select parity b...

Page 18: ...that is provided by serial server and can be connected by other TCP IP nodes The port is connected to relative serial ports of serial server System will automatically distribute local port number whe...

Page 19: ...ge of keep alive connection is 0 65535 Note If the keep alive connection is set to 0 it means this function is disabled RealCom Choose whether to turn on RealCom function Options are Off On 3 4 IP Fil...

Page 20: ...ide of filtering rule 1 10 Num Display the number of IP address filtering rules state Enable and disable filtering rule Access Permission Set access permission options are Allow allow to access the IP...

Page 21: ...nterface Interface Element Description MAC Filtering Enable or disable MAC address filtering rules Filtering Rule Set access permission for other MAC address to access this system outside of filtering...

Page 22: ...er Main Menu System Config Relay Warning Interface Description Relay warning interface as follows Main elements configuration description of relay warning interface Interface Element Description Alarm...

Page 23: ...rm Function Description On the page of Storm Suppression user can achieve suppression of port broadcast storm Operation Path Open in order Main Menu System Config Storm Interface Description Storm int...

Page 24: ...User Manual 3onedata proprietary and confidential 18 Copyright 3onedata Co Ltd 3 5 10 20 30 Limited type Choose limit type Options are Broadcast Unknown Multicast Unknown Unicast...

Page 25: ...nction Description On the page of System File Management user can conduct following operations Restore factory defaults Upload and download configuration files System upgrading Operation Path Open in...

Page 26: ...uploaded to other homogeneous devices achieving repeated usage after one time configuration Upload Configuration Configure the switch via uploading configuration files information Upgrade Firmware fro...

Page 27: ...ws The main element configuration description of User Password interface Interface Element Description User name Login name setting of WEB configuration interface Password Login password setting of WE...

Page 28: ...ecific method is adopt BlueEyes_ software to search and use restore factory setting function to initialize the password Both of the initial user name and password are admin 3 Is configuring via WEB br...

Page 29: ...bright what s the reason Possible reasons include Not connected to the power socket troubleshooting connected to the power socket Power supply or indicators faults troubleshooting change the power su...

Page 30: ...e system and power on again 4 The switch halts after communicate for a period time and returns to normal after reboot what s the reason Reasons may include Surrounding environment disturbs the product...

Page 31: ...ccident natural disaster incorrect operation or improper installation In order to ensure that consumers benefit from our company s managed switch products consumers can get help and solutions in the f...

Page 32: ...epair replacement or return customers should firstly confirm with the company technical staff and then contact the company salesmen and solve the problem According to the company s handling procedure...

Page 33: ...3onedata Co Ltd 3onedata Co Ltd Headquarter address 3 B Zone 1 Baiwangxin High Technology Industrial Park Song Bai Road Nanshan District Shenzhen Technology support tech support 3onedata com Service...