background image

MDI (straight-through cable) 

 
 
 
 
 

 
MDI-X (Cross over cable) 

 
 
 
 
 

 

MDI/MDI-X auto connection makes switch easy to use for 

customers without considering the type of network cable. 

Serial port connection 

RS-232 adopts RJ45 connector. The PIN define is as follows:   
RS-232 port:   
 
 
 

PIN 

PIN define 

Description 

TXD 
 
 

Transmit data 

RXD 

Receive data 

 

CTS

Optional

  Clear to send 

 

RTS

Optional

  Request to send 

 

GND 

Signal ground 

 
RS-485/422 port: 

 

PIN  RS-485 PIN define  RS-422 PIN define 

D+ 

 

T+ 

D

-

 

T

-

 

 

GND 

GND 

-- 

R+ 

-- 

R

-

 

LED Indicator

 

LED indictor light on the front panel of product, the function of 
each LED is described in the table as below. 

System statue LED 

LED 

Indicate 

Description 

PWR 

ON 

Power is connected/Function natural

 

OFF 

Power is  disconnected or function 
nu-natural

 

LINK 

ON 

Ethernet port connect successfully 

Flashing  Ethernet port has data transmission 

OFF 

Ethernet port connect unsuccessfully 

RX1 

OFF 

None data receive 

Flashing  In receiving data 

TX1 

OFF 

None data transmit 

Flashing  In transmitting data 

 

Installation

 

Before installation, confirm that the work environment meet the 
installation require, including the power needs and abundant 
space. Whether it is close to the connection equipment and other 
equipments are prepared or not.   
1. Avoid in the sunshine, keep away from the heat fountainhead or 

the area where in intense EMI. 

2. Examine the cables and plugs that installation requirements. 
3. Examine whether the cables be seemly or not (less than 100m) 

according to reasonable scheme.   

4. Screws, nuts, tools need to be prepared in advance of your own. 
5. Power: 9~48VDC power input 
6. Environment: working temperature -40

75

 

Storage Temperature: -40

85

 

Relative humidity 5%

95% 

DIN-Rail mounting 

Product support wall or rail mounted, DIN rail accessories can 
purchase in the purchase of the product. 

 

Wiring Requirements 

Cable laying need to meet the following requirements:

 

1. It is needed to check whether the type, quantity and 
specification of cable match the requirement before cable 

laying;

 

2. It is needed to check the cable is damaged or not, factory 
records and quality assurance booklet 

before cable laying;

 

3. The required cable specification, quantity, direction and 
laying position need to match construction requirements, 

and cable length depends on actual position;

 

4. All the cable cannot have break-down and terminal in the 

middle;

 

5. 

Cables should be straight in the hallways and turning;

 

6. Cable should be straight in the groove, and cannot beyond 
the groove in case of holding back the inlet and outlet holes. 
Cables should be banded and fixed when they are out of the 

groove;

 

7. User cable should be separated from the power lines. 

1

8

Reviews: