Below is a summary of steps to follow each time a 3M™ Versaflo™ TR-800 Powered Air Purifying Respirator (PAPR) is worn.
1. Push ‘Test’ button to confirm
battery charge – 5 bars =
80-100%.
2. Attach battery pack to
motor/blower. Gently tug bat-
tery pack to confirm a secure
connection.
3. Attach filter/cartridge (with filter
cover), and belt to motor/blower.
Gently tug filter/cartridge to confirm
a secure connection.
4. Turn on PAPR. Confirm LEDs
flash on startup. Confirm audible
alarm sounds.
5. Confirm airflow is sufficient.
Bottom of the ball above airflow
indicator zone flow level.
6. Align pins and insert breathing
tube into PAPR air outlet, turn
connector 1/4 turn clockwise.
Confirm connection by tugging
lightly on connection next to
outlet.
7. Inspect headtop for damage.
Connect breathing tube to headtop.
8. Don PAPR per workplace
procedures.
WARNING
!
This product is part of a system that helps reduce exposures to certain airborne contaminants. Before use, the wearer must read
and understand the
User Instructions
. Follow all local regulations. In the U.S., a written respiratory protection program must be
implemented meeting all the requirements of 29CFR1910.134, including training, fit testing and medical evaluation. In Canada,
CSA standard Z94.4 requirements must be met and/or requirements of the applicable jurisdiction, as appropriate.
Misuse may
result in injury, sickness or death.
For correct use, consult supervisor and
User Instructions
, or call 3M Technical Service in USA
at 1-800-243-4630 and in Canada at 1-800-267-4414.
Quick Start Guide: TR-800
NOTE: This sheet supplements, but does not replace,
User Instructions.
Always read and follow
User Instructions
.