Integrating the SC500 USB Controller
13
3M Touch Systems Proprietary Information
Table 2. LED Diagnostic Codes for SC500 Controllers
Flashes Self Test
Condition
Self Test
Bit
Description
What to do…
1 Reserved. 0
Reserved
2
ROM Error
1
Firmware EPROM checksum
verification error
No recovery. Replace the controller.
3 Reserved. 2
Reserved
4 Block
1
checksum Error
3
Operating parameters invalid
(using defaults).
Cycle power off and on. If problem
persists, recalibrate
5
Hardware error
4
Power-up touch screen
connector voltages that are
out of range.
Check connection to the touch screen
6 Reserved. 5
Reserved
7 Reserved. 6
Reserved
What's Next?
Since this is a HID (human interface device) compatible controller, the controller will
operate independent of a 3M Touch Systems driver. You must obtain a HID
calibration utility from the 3M Touch Systems website for initial calibration.
Additional 3M Touch Systems documentation is available from the corporate website
at www.3Mtouch.com or from the Touch Solutions CD (P/N 19-640).