background image

January 2011

78-0013-3884-3-A

3

3M

 Scotchcast

 

Encapsulation/Cable Capping Kit 3817

Instructions

1.  Clean all cable surfaces that compound will contact. 

Use of 3M

 Service Wire Cleaning Kit 4415 is 

recommended.

Fold all connectors back

beyond exposed shield.

Thoroughly scuff

and clean 4" (102 mm)

5/8"

16 mm

1/4"

6 mm

1 1/4"

32 mm

Figure 1

2.  If splicing, see Figure 1.

3.  Connect shields per system standard procedure. Splice 

conductors and fold back connectors as shown.

4.  Center splice bundle in cross arm of "T" foam spacer 

(Fig. 2).

Scuff 4"

(102 mm)

(1)

(2)

(3)

Fold 1,2,3 over splice

Figure 2

5.  Fold base of spacer over splice bundle. Overlap both 

"T" arms over splice bundle. Apply 3M

 Scotchmate

 

Hook and Loop Fastener.

6.  Below 60°F-warm compound by holding in hands, 

etc. Above 60°F-use compound immediately. To mix: 

Grasp clear end of the closed mixing bag and squeeze 

compound toward center barrier (Fig. 3). Completely 

separate barrier and thoroughly mix by squeezing back 

and forth 30-40 times to reach uniform color. Strip 

compound from corners during this process.

Figure 3

7.  Cut off top of bag 3/4" from top. Open carefully with 

sliding action and insert splice into bag.

8.  Squeeze or fold bottom of bag around splice, removing 

air and covering spacer with compound. Wrap vinyl 

tape upwards from spacer to cable (Fig. 4).

Figure 4