background image

 

 

_______________________________________________________________________________________________ 
3M B&CS Laboratory Europe 

 

  Page 1 / 2 

3M France Customer Application Center 
Avenue Boulé   PO box 28 
F-95250 Beauchamp (France) 

 

Low Range Shortening Monitor

 

LRSM 

 

Technical Data 

 

TD 250

 

Date : Nov 2005 

Supersedes : April 2004 

Author : EK/CB 

 

Introduction :

 

Shortening continually 
breaks down through normal 
use. This process is charac-
terized by a modification of 
the structure of the constitu-
ent molecules (Triglyc-
erides). The by-products that 
are formed are mainly Polar 
Compounds, among others 
are Free Fatty Acids 
(F.F.A.). The 3M Low 
Range Shortening Monitor 
utilizes the free fatty acid 
concentration as an indicator 
to the degree of shortening 
breakdown. 
 
 

Product Description :

 

A test is a stiff white paper strip 
(0,7 x 9.5 cm), having near one 
end of the strip, four blue bands 
across its width. A red line will 
differentiate the Low Range 
Shortening Monitor from Stan-
dard Shortening Monitor. 
 
 
 
 
 
 
 
 

Packaging :

 

 

       

 Per 200

 

20 tests strips/

plastic tube

 

1 plastic tube/box 
10 boxes/case  
(i.e. 200 strips/case) 

or

 

 

      Per 200

 

50 tests strips/

plastic tube

 

4 plastic tubes/case 
 (i.e. 200 strips/case) 
 
 

Product Use : 

The 3M LRSM strip is dipped 
into shortening at operating 
temperature. By simply count-
ing the number of yellow 
bands, the stage of shortening 
breakdown is indirectly deter-
mined. 
As shortening breaks down, the 
free fatty acid concentration 
increases, causing a greater 
number of bands on the 3M 
LRSM strip to change color. A 
blue band will change com-
pletely to yellow at a specific 
free fatty acid concentration 
(see diagram). 
 
 
 
 

 

 
 

 
 
 
 
 
 
 
  FFA 

> 2,5 % 

 
  FFA 

> 2,0 % 

 
  FFA 

> 1,5 % 

 

 

 

FFA > 1,0 % 

 
 
 

Applications : 

The product can be used in all 
types of frying oils and fats 
(animal, vegetable, and blends) 
and fryers, provided the test is 
done at operating temperature 
(between 160°C and 185°C). 
 
 

Product advantages :

 

 

Easy to use

 : no need for 

skilled people. 

 

Quick 

: immediate results. 

Determination is made 30 
seconds after dipping the 
test strip into shortening. 

 
 
 

 

Reviews: